    W A YNE COMBUSTION SYSTEMS 801 GLASGOW A VE. FORT W A YNE, IN 46803 ELECTRIC SHOCK HAZARD OVERHEA TING HAZARD HIGH VOL T AGES ARE PRESENT IN THIS EQUIPMENT . FOLLOW THESE RULES TO A VOID ELECTRIC SHOCK.  Use only a properly grounded circuit. A ground fault interrupter is recommended.  Do not spray water directly on burner .  T urn off powe ...

  • Wayne P265-EP - page 2

    1 These instructions were prepared for the guidance of those installing this particular gas conversion burner . While thy apply i n principle to all installations, they should not be interpreted as meaning the only safe and economical way to install a conversion burner . It may be necessary to deviate from these instructions in some instances in or ...

  • Wayne P265-EP - page 3

    2 FLUE PIPE AND CHIMNEY The flue pipe should be carefully inspected and replaced if necessary in connection with installation of a draft hood. All installations must operate with a negative draft overfire. Refer to your local gas company or codes for assistance or to the furnace and/or boiler manufacturer for recommendations. The flue pipe entrance ...

  • Wayne P265-EP - page 4

    3 FIGURE 2 FIGURE 3 FIGURE 4 1/2” (12.7 mm) Minimum rise 1/4” (6.35 mm) to the foot (.305 m) Minimum rise 1/4” (6.35 mm) to the foot (.305 m) Minimum rise 1/4” (6.35 mm) to the foot (.305 m) 90˚ (1.57 rad) ANGLE TYPE DRAFT HOOD (Always install in a vertical position) ...

  • Wayne P265-EP - page 5

    4 PREP ARA TION OF FURNACE OR BOILER Clean combustion chamber thoroughly . Scrape and brush all heating surfaces and flue ways. Soot and fly ash are excellent insulators and unless removed the efficiency of the heating plant will be impaired. Plugged or restricted flue passages will prevent burner from operating properly . Be sure water column and ...

  • Wayne P265-EP - page 6

    5 COMBUSTION CHAMBERS The combustion chamber sizes given in Figure 5 are based on the maximum rated BTU capacity . If the input is to be permanently set at a reduced rate, the combustion chamber floor area can be reduced proportionately to the proposed input, allowing 200,000 BTU (21 1000kJ) per square foot (.093m 2 ) of combustion chamber floor ar ...

  • Wayne P265-EP - page 7

    6 NOTE: The BTU input valves on the preceding page show the approximate hourly input of the burner for the various drill sizes shown. T o determine the actual input of the burner: 1) T urn off all other gas appliances. 2) The hand on the dial with the lowest cubic feet value (fastest revolving dial) should be clocked for one complete revolution . 3 ...

  • Wayne P265-EP - page 8

    7 ELECTRICAL WIRING The power burner is shipped completely wired. It is only necessary to supply the 1 15 volt circuit, thermostat and limit circuit. All wiring must conform with the National electric Code or the code legally authorized in the locality where the installation i s being made. The burner , when installed, must be electrically grounded ...

  • Wayne P265-EP - page 9

    8 After the piping and meter have been checked completely , purge the system of air . Do not bleed the air inside the furnace. Be sure to relight all the gas pilots on other appliances. PURGING After the piping has been checked, all piping and appliances receiving gas through the meter shall be fully purged. A suggested method for purging th gas li ...

  • Wayne P265-EP - page 10

    9 ADJUSTMENT OF BURNER Starting the burner: 1. Depress the gas valve control knob on the combination gas valve and turn to “OFF”. Figure 9. 2. Set room thermostat above room temperature and let burner run five minutes to purge the unburned gas from the unit. 3. Set thermostat below room temperature. 4. T urn gas valve control to “PILOT”. 5. ...

  • Wayne P265-EP - page 11

    10 P265DI - JUNCTION BOX ROT A TED P265DI ...

  • Wayne P265-EP - page 12

    11 All adjustments below must be made with the following instructions: 1. Draft Gauge 3. CO T ester 2. O 2 or CO 2 Analyzer 4. W ater Column Gauge After the burner has been in operation for 10 minutes and if a neutral pressure point adjuster was installed, proceed as follows. Start from the wide open position and gradually close the neutral pressur ...

  • Wayne P265-EP - page 13

    12 GENERAL INSTRUCTION Gas burners require the services of an experienced technician for proper setting and adjustment. If the burner does not appear to be operating properly , DO NOT A TTEMPT TO ADJUST THE BURNER YOURSELF , but call in a competent serviceman. A homeowner should be able to check several possible causes of shutdown before calling in ...

  • Wayne P265-EP - page 14

    13 P 265-EP , P265F-EP , P250AF-EP INTERMITTENT PILOT INSTRUCTION FOR HONEYWELL SYSTEM ST ARTING BURNER 1. Depress the gas valve control knob on the combination gas valve and turn to “OFF”. See Figure 9. 2. Set the room thermostat above room temperature and wait five (5) minutes. 3. Set thermostat below room temperature. 4. T urn gas control va ...

  • Wayne P265-EP - page 15

    14 IMPORT ANT : The electronic S8600 Control Module cannot be repaired. If troubleshooting procedure indicates a malfunction in the S8600 the S8600 Control Module must be replaced. Intermittent pilot systems should be serviced only by trained and experienced personnel. SEQUENCE OF OPERA TION 1 THERMOST A T (CONTROLLER) CALLS FOR HEA T 2 SP ARK GENE ...

  • Wayne P265-EP - page 16

    15 S8600, S8610 TROUBLESHOOTING GUIDE NOTE: Before troubleshooting, familiarize yourself with the start up and checkout procedure. Check line voltage power , low voltage transformer , limit controller , thermostat (controller) and wiring. Also, check air proving switch on combustion air blower system (if used) and that vent damper (if used) is open ...

  • Wayne P265-EP - page 17

    16 P250AF/P265-DI DIRECT SP ARK IGNITION HONEYWELL SYSTEM Starting the burner: 1) T urn the gas valve control knob to “OFF”, wait five minutes. 2) T urn gas valve control knob to “ON”. 3) Set room thermostat above room temperature. 4) If burner does not light, SHUT OFF BURNER COMPLETEL Y AND WAIT FIVE MINUTES, then repeat steps 1 through 3 ...

  • Wayne P265-EP - page 18

    17 TROUBLESHOOTING Although the following tests can be made using standard volt meter , it is quicker and more convenient to use a Fenwal Model 05-125539-001 T est Adapters. PRELIMINARY CHECKS 1. Input Polarity If a spark is present and the gas valve opens for the flame establishing period but then locks out at the end of other to ten seconds, chec ...

  • Wayne P265-EP - page 19

    18 T o measure flame current, first shut of f the power to the system and then remove the flame sensing lead wire form the electrode terminal and insert a 0-50 DC microamp meter in series with the sensor electrode and the sensor lead wire. “Plus” terminal of meter to component board and “negative”: terminal to sense electrode. Energize the ...

  • Wayne P265-EP - page 20

    19 P265 P265F P265EP P265FEP 1 Air Tube & Housing Assy . 5” (127mm) Burner 62715-001 • • 1 Air Tube & Housing Assy . 8” (203.2mm) Burner 62715-003 • • 1 Air Tube & Housing Assy . 1 1” (279.4mm) Burner 62715-005 • • 1 Air Tube & Housing (F) 5” (127mm) Burner 62715-002 • • 1 Air Tube & Housing (F) 8” (203 ...

  • Wayne P265-EP - page 21

    20 P250AF P250AF-EP P250AF-DI 1 Control Box Assembly 62296 • • 1 Power Cord Assembly 60182-002 • • 1 Transformer 60186-003 • • 1 Relay 60187 • • 1 Control Box Cover 62899-001 • • 1 Motor and Blower Assembly 60172-002 • • 1 Air Shutter Stationary Part 61874 • • 1 Air Shutter Disc 61770-002 • • 1 Air Tube and Housing A ...

  • Wayne P265-EP - page 22

    21 P ARTS LIST - P265/P265F SERIES GAS BURNERS 62903-001 Control Box/Strap Assembly 1 • • • • •••• • 60182-002 Power Cord Assembly 1 • • • 60186-004 T ransformer - 24V 1 • • • • •••• • 100986-002 Relay 1 • • • • •••• • 62899 Control Box Cover 1 • • • • •••• • 60172-002 Mo ...

  • Wayne P265-EP - page 23

    22 P ARTS LIST - P250AF SERIES GAS BURNERS 62903-001 Control Box/Strap Assembly 1 • • • 60182-002 Power Cord Assembly 1 • 60186-004 T ransformer-24V 1 • • • 100986-002 Relay 1 • • • 62899 Control Box Cover 1 • • • 60172-002 Motor/Blower (inch end switch) 1 • • • 62901-001 Air Shutter - Stationar y Portion 1 • • ? ...

  • Wayne P265-EP - page 24

    23 Notes ...

  • Wayne P265-EP - page 25

    24 MSR & MSR-DC 22019-003 Rev . C 08/15/00 LIMITED W ARRANTIES FOR OIL AND GAS BURNERS, MADE BY W A YNE AND USED IN RESIDENTIAL INST ALLA TIONS W A YNE COMBUSTION SYSTEMS (“W A YNE”) warrants to those who purchase its Oil Burner Models for resale or for incorporation into a product of resale, that its burner is free from defects in material ...

Fabricant Wayne Catégorie Burner

Les documents que nous recevons du fabricant de l'appareilWayne P265-EP peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Wayne
- manuels d’utilisations P265-EP
- fiches produit Wayne
- dépliants
- ou étiquettes-énergie Wayne P265-EP
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Wayne P265-EP.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Wayne P265-EP, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Wayne P265-EP. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Wayne P265-EP.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Wayne P265-EP, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Wayne P265-EP par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Wayne P265-EP.

Le manuel d’utilisation complet Wayne, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Wayne P265-EP - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Wayne P265-EP, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lWayne P265-EP qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Wayne P265-EP - qui devraient nous aider dans les premières étapes lors de l'utilisation Wayne P265-EP
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Wayne P265-EP
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Wayne P265-EP dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Wayne P265-EP?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Wayne P265-EP, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Wayne P265-EP il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)