    ROOM AIR CONDITIONER SERVICE MANUAL CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. website: http://www.lgservice.com e-mail: http://www.lgeservice.com/techsup.html MODEL : M5403R, M5203R, M5203L, M6003R, WM-6011, LWJ0611PCG, LWC061JGMK1 D r y F a n C o o l ...

  • Goldstar M5203L - page 2

    —2— CONTENTS 1. PREF A CE ................................................................ 2 1.1 FEA TURES.................................................................. 2 1.2 SPECIFICA TIONS ...................................................... 3 1.3 SAFETY PRECA UTIONS ........................................... 3 1.4 INSULA TION RESIST A ...

  • Goldstar M5203L - page 3

    1.2 SPECIFICA TIONS • NO TE: Specifications are subject to minor change without notice f or fur ther improv ement. —3— MODELS ITEMS COOLING CAP ACITY (BTU/h) 5,300 5,200 5,200 6,000 6,000 PO WER SUPPL Y (Phase, V , Hz) 1ø , 115V , 60HZ INPUT (W) 530 470 610 620 OPERA TING CURRENT (AMP .) 4.8 4.3 5.6 5.8 REFRIGERANT CONTROL CAPILLAR Y TUBE RE ...

  • Goldstar M5203L - page 4

    —4— 1.5 LOCA TIONS OF CONTROLS 1.5.1 CONTROLS Dry Fan Cool ON/OFF TIMER - STOPPING OPERATION • Everytime you push this button, when the unit is operating, timer is set as follows. (1Hour 2Hours 3Hours 4Hours 5Hours 6Hours 7Hours 8Hours 9Hours 10Hours 11Hours 12Hours Cancel) • The Setting Temperature will be raised by 2 ° F(1 ° C) 30min. l ...

  • Goldstar M5203L - page 5

    — 5 — 1.5.2 REMO TE CONTROLLER How to Insert Batteries 1. Remov e the cover from the bac k of the remote controller 2. Inser t two batteries. • Be sure that the (+) and (-) directions are correct. • Be sure that both batteries are new . 3. Re-attach the cov er . • Do not use rechargeab le batter ies. Such bat- teries diff er from standard ...

  • Goldstar M5203L - page 6

    — 6 — 2. DISASSEMBL Y INSTR UCTIONS 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Disconnect the unit from source of power . 2. Using a screwdriv er , remov e the screw that secures the front grille to control board. (See Figure 1) 3. Push the front grille up from the bottom. Pull the top of the front grille aw a y from the cabinet as the top ta ...

  • Goldstar M5203L - page 7

    — 7 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.1.3) 5. Remov e 2 screws that secure the air guide upper to air guide lower . (See Figure 6) ...

  • Goldstar M5203L - page 8

    — 8 — 2.2.3 MO T OR 1. Disconnect the unit from the power source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.1.3) 5. Remov e the air guide upper . (Ref er to Section 2.2.1) 6. Remov e the compressor , turbo fan, f an and shroud. (Ref ...

  • Goldstar M5203L - page 9

    — 9 — 2.3.2 COMPRESSOR 1. Remov e the front grille and cabinet. (Ref er to Section 2.1.2) 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the overload protector . (Ref er to Section 2.3.1) 4. After discharging the unit completely , unbrace the suction and discharge pipes at the compressor connections. 5. Remov ...

  • Goldstar M5203L - page 10

    — 10 — 2.3.6 PO WER CORD 1. Disconnect the unit from source of power . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Remov e 2 screws that secure control board to base pan and orifice. 5. Pulls the control board tow ard you. 6. Remov e the grounding screw . 7. Remov e a screw securing ...

  • Goldstar M5203L - page 11

    2.4.3 CAPILLAR Y TUBE 1. Remov e the cabinet. 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the air guide upper . (Refer to Section 2.2.1) 4. After discharging the refrigerant completely , unbraze the interconnecting tube of the capillary tube. 5. Remov e the capillar y tube. 6. Re-install by ref erring to the pr ...

  • Goldstar M5203L - page 12

    — 12 — Equipment needed: V acuum pump , charging cylinder , manifold gauge, br azing equipment, pinch-off tool capable of making a vapor proof seal, leak detector , tubing cutter , hand tools to remov e components and ser vice v alve. B A B A B A COMPOUND GAUGE SEE INSETS BELOW CAPILLARY TUBE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CONDENSER ...

  • Goldstar M5203L - page 13

    — 13 — 3. INST ALLA TION This air conditioner is designed with a button-down chassis so it can be easily installed in a window . 3.1 SELECT THE BEST LOCA TION 1. T o prev ent vibration and noise, mak e sure the unit is installed securely and firmly . 2. Install the unit where the sun does not shine directly on the unit. 3. The outside of the ca ...

  • Goldstar M5203L - page 14

    — 14 — Installation 3.2.2 BEFORE INST ALLA TION 1. Inser t the guide panels into the guides of the air condi- tioner . F asten the cur tains to the unit with scre ws (TYPE A) as shown Figure . 24. 2. Cut the adhesive-bac ked seal strip (TYPE D) to the window width. Remov e the backing from the seal strip and attach the seal strip to the undersi ...

  • Goldstar M5203L - page 15

    3 . INST ALL THE AIR CONDITIONER IN THE WINDO W a. Carefully lift the air conditioner and slide it into the open window . Make sure the bottom guide of the air conditioner drops into the notches of the L brac ket. See Figure . 27. IMPORT ANT : When the air conditioner drops into the L brack et, the air conditioner will be centered in window opening ...

  • Goldstar M5203L - page 16

    — 16 — REMO V AL FROM WINDO W T ur n the air conditioner off, disconnect the po wer cord, remov e the L brac ket and the scre ws installed through the top and bot- tom of the guide panels, and sa ve f or reinstallation later. Close the guide panels . Keeping a firm grip on the air conditioner , raise the sash, and carefully tilt the air conditi ...

  • Goldstar M5203L - page 17

    — 17 — 4.2 PIPING SYSTEM F ollowing is a brief description of the impor tant components and their function in what is called the refrigeration system. Ref erence should be made to Figure 32 to f ollow the refrigerating cycle and the flow of the refrigerant in the cooling cycle. COOLED AIR HOT DISCHARGED AIR MOTOR COMPRESSOR ROOM AIR HEAT LOAD C ...

  • Goldstar M5203L - page 18

    — 18 — 4.3 TR OUBLESHOO TING GUIDE In general, possib le trouble is classified in tw o kinds. The one is called Starting Failure which is caused by an electrical defect. The other is Ineffective Air Con- ditioning caused by a def ect in the refrigeration circuit and improper application. Unit is running but cooling is ineff ective . Ineffective ...

  • Goldstar M5203L - page 19

    — 19 — Fails to Start Improper ther mistor setting Loose ter minal connection Improper wiring Check of po wer source. Drop of power v oltage. Capacitor check. Replacement. Check of control panel setting. Compressor f ails only to star t. Def ect of compressor capacitor . Replacement of compressor (Motor damaged). Irregular motor insulation ( ? ...

  • Goldstar M5203L - page 20

    — 20 — Is the Trans output power AC 115V? Is the Trans output power about AC 14V? Is shorted the Trans. output? Is output Voltage of IC01D DC 12V? Is output Voltage of IC02D DC 5V? Is the voltage No.20 of Micom DC 5V? Exchange Main P.W.B Ass'y. Is the connection between Main and Display all right? Is the reset circuit all right? (The No.16 ...

  • Goldstar M5203L - page 21

    — 21 — Is Temp. setting set lower than Room Temp.-0.5 ° C? Is the voltage No.11 of IC01M 0V? • Exchange IC01M. • Set the Temp. setting to higher Temp. • Wait 3 Minutes Is the Unit for 3 minutes delay? • Exchange MAIN P.W.B Ass'y. Is the voltage N0.6 of IC01M DC 5V? • Check the RY-COMP. • Check the wiring Diagram. NO NO NO NO Y ...

  • Goldstar M5203L - page 22

    — 22 — Is the voltage of Battery about over 2.3V? • Exchange Receiver Ass'y. Is the connection of CN-DISP2 all right? Is the voltage No.10 of CN-DISP2 on Main P.W.B Ass'y DC 5V? • Exchange the battery. • Check the P.W.B pattern. • Connect connector to CN-DISP2 exactly. NO NO NO YES YES YES P ossible T rouble 5 • Romote contr ...

  • Goldstar M5203L - page 23

    — 23 — ROOM AIR CONDITIONER V OL T A GE LIMITS NAME PLA TE RA TING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CA USE REMED Y F an motor will not run. No power Check v oltage at outlet. Correct if none. P ower supply cord Check v oltage to rotar y s witch. If none, check power supply cord. Replace cord if circuit is open. Rotar y s witc ...

  • Goldstar M5203L - page 24

    — 24 — COMPLAINT CA USE REMED Y F an motor noise. F an If crac ked, out of balance , or par tially missing, replace it. Blower If crac ked, out of balance , or par tially missing, replace it. Loose set screw Tighten it. W orn bear ings If knocking sounds contin ue when running or loose, replace the motor . If the motor hums or noise appears to ...

  • Goldstar M5203L - page 25

    — 25 — COMPLAINT CA USE REMED Y Compressor cycles on F an motor If not running, deter mine the cause. Replace if ov er load required. Condenser air flow Remo ve the cabinet, inspect the interior surf ace restriction of the condenser . If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush. Clean the inter ior base be ...

  • Goldstar M5203L - page 26

    — 26 — LOCA TION NO . 1 2 3 4 5 6 7 8 5. SCHEMA TIC DIA GRAM 5.1 CIRCUIT DIA GRAM • MODEL : M5403R, M5203R, M5203L, M6003R, WM-6011, L WJ0611PCG, L WC061JGMK1 Q'TY PER SET 1 1 1 1 1 1 1 1 DESCRIPTION PO WER CORD ASSEMBL Y F AN MO TOR COMPRESSOR DISPLA Y P .W .B ASSEMBL Y MAIN P .W .B ASSEMBL Y THERMIST OR CAP ACIT OR O WERLOAD PR O TECT ...

  • Goldstar M5203L - page 27

    — 27 — 5.2 ELECTRONIC CONTR OL DEVICE ...

  • Goldstar M5203L - page 28

    — 28 — 5.3 COMPONENTS LOCA TION (FOR MAIN P .W .B ASM) 5.4 COMPONENTS LOCA TION (FOR DISPLA Y P .W .B ASM) ...

  • Goldstar M5203L - page 29

    — 29 — 6. EXPLODED VIEW 135313 352390 267110 152302 130410 359012 W48602 135312 354210 349480 352380 149980 559011 346811 554030 W48602 130910 264110 238310 W0CZZ 249950 268714 263230 550140 554160 567502 352115 552111 352113 35211A 237200 268712 ...

  • Goldstar M5203L - page 30

    — 30 — 7. SER VICE P ARTS LIST LOCA TION NO DESCRIPTION REMARKS M5403R M5203R M5203L 130410 BASE ASSY , SINGLE 3041A10011E R 130910 CABINET ASSY ,SINGLE 3091A10020A R 135312 GRILLE ASSY , FRONT(SINGLE) 3531AR1644H 3531AR1644U R 135313 GRILLE ASSY , INLET 3530A10039A R 137215 P ANEL, CONTROL 3720A20017A 3720A20111A R 149980 SHR OUD 4998A10006A 4 ...

  • Goldstar M5203L - page 31

    — 31 — M6003R WM-6011 L WJ0611PCG L WC061JGMK1 130410 BASE ASSY , SINGLE 3041A10011E 3041A10011E 3041A10011E 3041A10011E R 130910 CABINET ASSY , SINGLE 3091A10020A 3091A10020A 3091A10020D 3091A10020D R 135312 GRILLE ASSY , FRONT(SINGLE) 3531AR1644H 3531AR1644T 3531AR1644T 3531AR1644T R 135313 GRILLE ASSY , INLET 3530A10039A 3530A10039A 3530A100 ...

  • Goldstar M5203L - page 32

    P/No.: 3828A20038B February, 2003 Printed in Korea ...

Fabricant Goldstar Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilGoldstar M5203L peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Goldstar
- manuels d’utilisations M5203L
- fiches produit Goldstar
- dépliants
- ou étiquettes-énergie Goldstar M5203L
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Goldstar M5203L.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Goldstar M5203L, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Goldstar M5203L. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Goldstar M5203L.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Goldstar M5203L, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Goldstar M5203L par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Goldstar M5203L.

Le manuel d’utilisation complet Goldstar, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Goldstar M5203L - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Goldstar M5203L, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGoldstar M5203L qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Goldstar M5203L - qui devraient nous aider dans les premières étapes lors de l'utilisation Goldstar M5203L
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Goldstar M5203L
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Goldstar M5203L dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Goldstar M5203L?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Goldstar M5203L, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Goldstar M5203L il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)