    Contents ................ 01 ....... B lood Pressure Monitor Intended Use 02 ....... 1 . What is blood pressure ? 02 ....... 2 . Why is it useful to measure blood pressure at home ? .......... A. WHO blood pressure classi ¿ cations .......... B. V ariations in blood pressure 04 ....... 3 . Important information before use of the unit 06 ....... 4 ...

  • Citizen ch-17 - page 4

    Contents ................ 10 ....... 8 . Symbol Di ¿ nitions. 12 ....... 9 . How to measure. .......... A. Inserting batteries in position. .......... B. Setting date and time. .......... C. Steps to take blood pressure measurement. .......... D. Storing recalling and erasing measurement data. .......... E. T o change batteries. 15 ....... 10 . Ma ...

  • Citizen ch-17 - page 5

    MEDICAL DISCLAIMER This manual and product are not meant to be a substitute for advice provided by your doctor or other medical professional. Y ou are not to use the information contained herein, or this product for diagnosing or treating a health problem or prescribing any medication. If you have or suspect that you have a medical problem, promptl ...

  • Citizen ch-17 - page 6

    Blood pressure is a measurement of the force of blood À owing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the cardiac cycle. The highest pressure in the cycle is called the systolic blood pressure, the lowest is the diastolic blood pressure. Both pressure readings, the systolic and the dia ...

  • Citizen ch-17 - page 7

    as near as possible to measuring the blood pressure in an environment that is close to this, is why it is useful to take the measurement at home. A. WHO blood pressure classi fi cations Standards for assessment of high or low blood pressure without regard to age, have been established by the World Health Organization (WHO), as shown in the chart. ...

  • Citizen ch-17 - page 8

    The thick line represents sleep. The rise in blood pressure at 4 PM (A in the graph) and 12 PM (B in the graph) correspond to an attack of pain. Please rest for at least 5~10 minutes before taking the measurement. T o allow your blood vessels to return to the condition prior to taking the measurement, please wait at least 3~5 minutes between measur ...

  • Citizen ch-17 - page 9

    Perform measurement quietly in a relaxed position. Do not wind the cuff over jacket or sweater sleeve, or measurement cannot be done. Keep in mind, that blood pressure naturally varies from time to time throughout the day and also is affected by lots of different factors such as smoking, alcohol consumption, medication and physical activity . Peopl ...

  • Citizen ch-17 - page 10

    A. Name of the parts 4 . Device description: 6 PM : A V G m m Hg m m H g /m in START STOP M Pulse DIA SY S SETTING BUTTON FUNCTION BUTTON LCD DISPLA Y ST ART/STOP BUTTON ( Stand-by) RECALL MEMORY BUTT ON WRIST CUFF CARRYING CASE ALKALINE BA TTERY UM-4 (AAA) 1.5 V x 2 * Figure No.3 M ...

  • Citizen ch-17 - page 11

    PM : AV G B. Description of display symbols HEART RA TE SYMBOL LAST 3 READING A VERAGE LOW BA TTERY SYMBOL HOUR : MINUTE MONTH/DA TE SYSTOLIC RA TE DIASTOLIC RA TE HEART RA TE 7 (ALSO REPRESENTS AS YEAR UNDER SETTING MODE) ...

  • Citizen ch-17 - page 12

    5 . Changing batteries * Figure No.4 A. Wrap the pressure cuf f around the wrist. a. The display of the unit should be placed on the palm side of the wrist. b. The wrist should be bare. 6 . Attaching pressure cuff 8 Remove the battery cover at the left side of the unit and insert batteries into the battery compartment in accordance with ribbon stri ...

  • Citizen ch-17 - page 13

    B. Fasten the pressure cuff snugly . a. Do not pull strongly on the pressure cuff. b. Do not make the pressure cuff too tight. It is extremely important for the measured values, that the cuff is at the same height of the heart. Higher or deeper position will give deviations from the true value. 7 . Correct measurement position Measurement while sit ...

  • Citizen ch-17 - page 14

    SYMBOLS 8 . Symbol De fi nitions De fi nitions Heart Rate Symbol Last 3 Reading A verage This symbol appears when the battery power is excessively low or the polarity reverses. ᇄ We suggest you replace all batteries with new ones, and make sure the +/- polarities are properly positioned. This symbol appears when LCD displays average value of la ...

  • Citizen ch-17 - page 15

    Cuff has been placed incorrectly . SYMBOLS/ SYMPTOMS CONDITIONS/ CAUSES INDICA TION/ CORRECTION Note: If "EP" appears on the display , just return the device to your local distributor or importer . Shaking of the wrist with the cuff on. In À ation pressure exceeding 300 mmHg. Error determining measurement data. Wrap the cuf f properly so ...

  • Citizen ch-17 - page 16

    a. Open battery cover . b. Refer to the picture in positioning batteries. (Figure No.4) c. All LCD segments appear on the display in 3 seconds. 9 . How to measure A. Inserting batteries in position: a. Press " " button over 2 secs ("year" starts À ashing) Press " " button to set the correct year (201 1,2012,…2026) b ...

  • Citizen ch-17 - page 17

    c. Press" "button. All elements display '888' in 3 seconds. Afterward, displays the updated time. The measuring blood pressure symbol will À ash on the display and then the air pressure will automatically pump up to 195 mmHg. If blood pressure tends to be on the high level, the air pressure will automatically increase to the re ...

  • Citizen ch-17 - page 18

    E. T o change batteries: When " " show up on the display , the battery is weak. Change the batteries or it will not be possible to take blood pressure measurement. All batteries used must be the same type. Do not mix alkaline, standard(carbon-zinc) or rechargeable (cadmium) batteries. Do not mix old and new batteries. 14 b. Recalling data ...

  • Citizen ch-17 - page 19

    Use a piece of cloth with water or mild cleansing agent to clean the case and then use a piece of dry cloth to wipe it dry . Do not use gas or any strong cleansers in cleaning. When the unit is not to be used for a long time, remove the batteries. (Leaking of battery liquid can cause trouble) 10 .MAINTENANCE: Always keep the unit in the carrying ca ...

  • Citizen ch-17 - page 20

    The device measures the blood pressure of adult only . The device is not supposed to be used if your wrist has any wound or injury . In the event of the cuff pumping up and not stopping, please open the cuff at once. T o ensure precise measurement reading, recalibration of the device is recommended after 2 years from the date of purchase. Shipping ...

  • Citizen ch-17 - page 21

    Model Number Method of Measurement Range of Measurement Accuracy In À ation De À ation of Pressure Exhaust Display Sets of Memory Unit Dimension Unit Weight Cuff Size Operating T emperature T ransportation/ Storage T emperature Auto power off Power Supply Battery Life Accessories 14 .SPECIFICA TIONS: :CH-617 :Oscillometric :Pressure 0 ~ 300 mmHg ...

  • Citizen ch-17 - page 22

    This blood pressure monitor complies with the EC Directive and bears the CE mark "CE0197". This blood pressure monitor also complies with mainly following standards,(included but not limited) Safety standard: EN 60601-1 Medical electrical equipment part 1: General requirements for safety EMC standard: EN 60601-1-2 Medical electrical equip ...

  • Citizen ch-17 - page 23

    Manufacturer: HEAL TH & LIFE Co., Ltd. 9F , No. 186, Jian Y i Road, Zhonghe District, New T aipei City , T aiwan Authorized Representative in the European Community: EMERGO EUROPE Molenstraat 15, 2513 BH, The Hague, The Netherlands 19 Classi fi cation: - BF type applied part - Internally powered equipment - IPX0 - Not suitable for use in prese ...

  • Citizen ch-17 - page 24

    WEEE MARK If you want to dispose this product, do not mix with general household waste. There is a separate collection systems for used electronics products in accordance with legislation under the WEEE Directive (Directive 2002/96/EC) and is effective only within European Union. Information for Users on Collection and Disposal of used Batteries. T ...

  • Citizen ch-17 - page 25

    P/N:323101937 VER:001 Distributed by: Distributed by: ...

Fabricant Citizen Catégorie Blood Glucose Meter

Les documents que nous recevons du fabricant de l'appareilCitizen ch-17 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Citizen
- manuels d’utilisations ch-17
- fiches produit Citizen
- dépliants
- ou étiquettes-énergie Citizen ch-17
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Citizen ch-17.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Citizen ch-17, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Citizen ch-17. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Citizen ch-17.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Citizen ch-17, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Citizen ch-17 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Citizen ch-17.

Le manuel d’utilisation complet Citizen, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Citizen ch-17 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Citizen ch-17, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCitizen ch-17 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Citizen ch-17 - qui devraient nous aider dans les premières étapes lors de l'utilisation Citizen ch-17
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Citizen ch-17
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Citizen ch-17 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Citizen ch-17?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Citizen ch-17, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Citizen ch-17 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)