Manuel d’utilisation Cooper Lighting Talon Architectural Area Luminaire

24 pages 4.79 mb
Télécharger

Aller à la page of 24

Summary
  • Cooper Lighting Talon Architectural Area Luminaire - page 1

    T alon Ar chitectural Ar ea Luminair e ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 2

    TALON VERSATILE PERFORMANCE Talon’s ingenious blend of performance and versatility allows application specific illumination by way of fourteen [14] high efficiency, field rotatable optical systems. Offered with the unrivaled Spill Light Eliminator [SL] optic for areas requiring strict light trespass control, and the premier Automotive Front Row [ ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 3

    SITE + PARKING | ROADWAY | PATH OF EGRESS IMPENETRABLE FORM Coupling precise mechanical design with premium quality materials, the Talon site light is constructed to sustain the rigors of outdoor operation. Thick wall die-cast aluminum construction and channel set silicone gasketing form an impenetrable IP65 barrier optimizing optical efficiency an ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 4

    3 4 PERFORMANCE + VERSATILITY MAXIMIZE SITE UNIFORMITY Add sparkle to your site and maximize pole spacings with sag glass optical systems offered in both cutoff and semi-cutoff configurations. For applications mandating full cutoff, choose from a complete offering of flat glass vertical lamp solutions. The vertically lamped family of optical system ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 5

    LEADING SPILL CONTROL The Spill Light Eliminator [SL] optic is the industry leader in effective spill light control, eliminating light beyond one [1] mounting height behind the pole with no sacrifice in forward illumination. Used along site perimeters and property lines, the Spill Light Eliminator keeps the light inside and the darkness out. ROTATI ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 6

    5 6 AUTOMOTIVE SOLUTIONS ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 7

    OUTDOOR SITE LIGHTING THAT ENGAGES CUSTOMER AWARENESS. Exterior site lighting provides the first impression of an automotive dealership and is an outward expression of image. During daytime hours the exterior site lighting fixture form should be selected to lend focus to dealership architecture and branding. For evening opera tion, properly illumin ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 8

    7 8 QUALITY + DURABILITY DURABLE CAST CONSTRUCTION Low-copper alloy die-cast aluminum construction offers corrosion resistance while precise tolerance control ensures tight nesting of the door and housing. Combining heat extracting reveal channels with independent optical and electrical chambers that isolate heat producing sources, the Talon’s ho ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 9

    CONFIDENCE-INSPIRING QUALITY BEYOND THE SUM OF ITS PARTS. From the stainless steel hinges to the rugged housing, every detail of the Talon construction is precisely designed with industry leading craftsmanship. Heavy-wall die-cast aluminum construction, premium TGIC [triglycidyl isocyanurate] polyester powder coat paint and an IP65 rate d optical c ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 10

    9 10 CONTROL + EFFICIENCY 0° [nadir] 180° UH Back Forward Uplight 30° 30° 60° 60° 80° 80° 90° 90° 100° 100° UL UL BVH FVH BH FH BM FM BL FL LUMINAIRE CLASSIFICATION The IESNA’s revised Luminaire Classification System [TM15-07 revised] creates a new basis of measurement for site lighting visibility and adjacent property interaction. Th ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 11

    STEPPING UP TO THE CHALLENGE. As visual research advances so too the core understanding of how light interacts with surrounding communities and nocturnal env ironments. Utilizing this knowledge, Federal programs, national organizations and industry leaders institute guidelines for illuminating an area safely and securely while reducing energy, elim ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 12

    ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 13

    ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 14

    13 14 MOUNTING Extruded 8" [TLM Talon Medium] or 10 1/2" [TLL Talon Large] aluminum arm includes internal bolt guides allowing for easy positioning of fixture during installation to pole or wall surface. Standard single carton packaging of housing, square pole arm and round pole adapter for contractor friendly arrival of product on site. ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 15

    FINISH Housing and arm finished in a 5 stage premium TGIC polyester powder coat paint, 2.5 mil nominal thickness for superior protection against fade and wear. Standard colors include black, bronze, grey, white, dark platinum, and graphite metallic. RAL and custom color matches available. Consult the McGraw-Edison Architectural Colors brochure for ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 16

    15 16 OPTIONS + ACCESSORIES ARM MOUNT Standard 8" [TLM] or 10 1/2" [TLL] extruded aluminum arm features internal bolt guides for twin support rods. Round pole mounting accommodated by utilizing provided round pole adapter between the fixture arm and pole shaft. EXTERNAL MAST ARM ADAPTER [MS] Cast aluminum mast arm adapter secures fixture ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 17

    OPTIONS [Factory installed and shipped complete with luminaire] Electrical F =Single Fuse [120, 277 or 347V] FF =Double Fuse [208, 240 or 480V] Q =Quartz Restrike EM =Quartz Restrike w/Delay [Also Strikes at Cold Start] EM/SC =Quartz Emergency Separate Circuit PT =Electrical Power Tray [Standard on TLL] P =Button Type Photocontrol [TLM Only] R =NEM ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 18

    17 18 STEEL POLES + BRACKETS ORDERING INFORMATION SAMPLE NUMBER: RSS4A20SFM2XG ISOTACH WIND MAP This map has been included to aid in pole selection with regard to geographic location. Although a less stringent 25-year mean recurrence map is sometimes used by other pole suppliers, it is our belief that the added measure of assurance offered with the ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 19

    FROM ANCHOR BOLTS TO LUMINAIRE AND EVERYTHING IN BETWEEN. Cooper Lighting offers a comprehensive line of steel and aluminum poles, brackets and mounting accessories to complete your sit e lighting application. Visit www.mcgraw-edison.com to view McGraw-Edison’s entire collection of mounting options. STEEL POLES [Specification Features] ROUND STRA ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 20

    19 20 ALUMINUM POLES + PHOTOMETRICS ALUMINUM POLES [Specification Features] ROUND STRAIGHT ALUMINUM [RSA] Fixture Mounting Drilled or Tenon [Must specify]. Shaft 6005-T6 aluminum alloy with polished finish. Handhole Flush reinforced 2 3/8" x 4 1/2" for 4" shafts. Handhole assembly with internal reinforcing frame. 3" X 5" fo ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 21

    PHOTOMETRICS [Complete IES files available at www.cooperlighting.com] FOOTCANDLE TABLE Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height. Mounting Footcandle Values for Height Isofootcandle Lines AB C D E 175W [3V/AS] 15' 1.70 0.85 0.34 0.17 -- 20' 1.00 0.50 0.20 ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 22

    21 22 TLM TALON MEDIUM ORDERING INFORMATION SAMPLE NUMBER: TLM-400-MH-MT-3F-FG-BK-HS VOLTAGE 5 120 =120V 208 =208V 240 =240V 277 =277V 347 =347V 480 =480V DT =Dual-Tap 6 MT =Multi-Tap 6 TT =Triple-Tap 6 5T =5-Tap 6, 7 DISTRIBUTION Horizontal Lamp 2F =Type II Formed 2S =Type II Segmented 3F =Type III Formed 3S =Type III Segmented 4F =Type IV Formed ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 23

    TLL TALON LARGE ORDERING INFORMATION SAMPLE NUMBER: TLL-1000-MH-5T-SL-FG-BK VOLTAGE 4 120 =120V 208 =208V 240 =240V 277 =277V 347 =347V 480 =480V DT =Dual-Tap 5 MT =Multi-Tap 5 TT =Triple-Tap 5 5T =5-Tap 5 DISTRIBUTION Horizontal Lamp 2F =Type II Formed 2S =Type II Segmented 3, 6 3F =Type III Formed 3S =Type III Segmented 3, 6 4F =Type IV Formed 4S ...

  • Cooper Lighting Talon Architectural Area Luminaire - page 24

    Cooper Lighting Customer First Center 1121 Highway 74 South Peachtree City , GA 30269 P: 770-486-4800 F: 770-486-4801 www .cooperlighting.com International Sales, USA Cooper Lighting 1121 Highway 74 South Peachtree City , GA 30269 P: 770-486-4800 F: 770-486-4801 Canada Cooper Lighting 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-400 ...

Fabricant Cooper Lighting Catégorie Landscape Lighting

Les documents que nous recevons du fabricant de l'appareilCooper Lighting Talon Architectural Area Luminaire peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Cooper Lighting
- manuels d’utilisations Talon Architectural Area Luminaire
- fiches produit Cooper Lighting
- dépliants
- ou étiquettes-énergie Cooper Lighting Talon Architectural Area Luminaire
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Cooper Lighting Talon Architectural Area Luminaire.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Cooper Lighting Talon Architectural Area Luminaire, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Cooper Lighting Talon Architectural Area Luminaire. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Cooper Lighting Talon Architectural Area Luminaire.

Manuel d’utilisation complet de l’appareil Cooper Lighting Talon Architectural Area Luminaire, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Cooper Lighting Talon Architectural Area Luminaire par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Cooper Lighting Talon Architectural Area Luminaire.

Le manuel d’utilisation complet Cooper Lighting, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Cooper Lighting Talon Architectural Area Luminaire - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Cooper Lighting Talon Architectural Area Luminaire, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCooper Lighting Talon Architectural Area Luminaire qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Cooper Lighting Talon Architectural Area Luminaire - qui devraient nous aider dans les premières étapes lors de l'utilisation Cooper Lighting Talon Architectural Area Luminaire
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Cooper Lighting Talon Architectural Area Luminaire
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Cooper Lighting Talon Architectural Area Luminaire dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Cooper Lighting Talon Architectural Area Luminaire?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Cooper Lighting Talon Architectural Area Luminaire, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Cooper Lighting Talon Architectural Area Luminaire il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)