  • Craftsman 919.7255 - page 1

    Operators Manual Permanently Lubricated 2-Stage Tw i n V Portable AIR COMPRESSOR • Safety Guidelines • Assembly • Operation • Maintenance • Service and Adjustments • T roubleshooting • Repair Parts Model No. 919.725500 CAUTION: Read the Safety Guidelines and All Instructions Carefully Befor e Operating. Sold by Sears Canada, Inc. T or ...

  • Craftsman 919.7255 - page 2

    2- ENG D24445 FULL ONE YEAR WARRANTY ON AIR COMPRESSORS If this air compressor fails due to a defect in material or workmanship within one year from the date of pur chase, RETURN IT TO THE NEAREST SEARS SERVICE CENTER THROUGHOUT CANADA AND SEARS WILL REP AIR IT , FREE OF CHARGE. If this air compressor is used for commer cial or rental purposes, the ...

  • Craftsman 919.7255 - page 3

    3- ENG D24445 SPECIFICA TION CHAR T Model No. 919-725500 Bore 2.375” Stroke High Pressur e - .54” Low Pressur e - 1.45” V oltage-Single Phase 120 Minimum Branch Circuit Requir ement 15 amps Fuse T ype Time Delay Air T ank Capacity - Gallons 25 ASME Approximate Cut-in Pr essure 145 Approximate Cut-out Pr essure 175 SAFETY GUIDELINES - DEFINITI ...

  • Craftsman 919.7255 - page 4

    4- ENG D24445 RISK OF EXPLOSION OR FIRE AL WA YS OPERA TE THE COMPRESSOR IN A WELL VENTILA TED AREA FREE OF COMBUSTIBLE MA TERIALS, GASOLINE OR SOL VENT V APORS. IF SPRA YING FLAMMABLE MA TERIALS, LOCA TE COMPRESSOR A T LEAST 20 FEET AW A Y FROM SPRA Y AREA. AN ADDITIONAL LENGTH OF HOSE MA Y BE REQUIRED. STORE FLAMMABLE MA TERIALS IN A SECURE LOCA ...

  • Craftsman 919.7255 - page 5

    5- ENG D24445 RISK OF BURSTING AIR T ANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE T ANK, AND RESUL T IN A VIOLENT T ANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJUR Y . HOW TO PREVENT IT WHA T CAN HAPPEN DRAIN T ANK DAIL Y OR AFTER EACH USE. IF T ANK DEVELOPS A LEAK, REPLACE IT IMMEDIA TEL Y WITH A NEW T ANK OR REPLA ...

  • Craftsman 919.7255 - page 6

    6- ENG D24445 HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN RISK TO BREA THING AIR OBT AINED DIRECTL Y FROM THE COMPRESSOR SHOULD NEVER BE USED TO SUPPL Y AIR FOR HUMAN CONSUMPTION. IN ORDER TO USE AIR PRODUCED BY THIS COMPRESSOR FOR BREA THING, SUIT ABLE FIL TERS AND IN-LINE SAFETY EQUIPMENT MUST BE PROPERL Y INST ALLED . I ...

  • Craftsman 919.7255 - page 7

    7- ENG D24445 HOW TO PREVENT IT WHA T CAN HAPPEN RISK OF BURNS TOUCHING EXPOSED MET AL SUCH AS THE COMPRESSOR HEAD OR OUTLET TUBES, CAN RESUL T IN SERIOUS BURNS. NEVER TOUCH ANY EXPOSED MET AL P ARTS ON COMPRESSOR DURING OR IMMEDIA TEL Y AFTER OPERA TION. COMPRESSOR WILL REMAIN HOT FOR SEVERAL MINUTES AFTER OPERA TION. DO NOT REACH AROUND PROTECTIV ...

  • Craftsman 919.7255 - page 8

    8- ENG D24445 HAZARD HOW TO PREVENT IT WHA T CAN HAPPEN RISK OF UNSAFE OPERA TION REVIEW AND UNDERST AND ALL INSTRUCTIONS AND WARNINGS IN THIS MANUAL. BECOME F AMILIAR WITH THE OPERA TION AND CONTROLS OF THE AIR COMPRESSOR. KEEP OPERA TING AREA CLEAR OF ALL PERSONS, PETS, AND OBST ACLES. KEEP CHILDREN AWA Y FROM THE AIR COMPRESSOR A T ALL TIMES . D ...

  • Craftsman 919.7255 - page 9

    9- ENG D24445 ACCESSORIES This unit is capable of powering the following Accessories. The accessories are available through the curr ent Power and Hand T ool Catalog or full-line Sears stores. Accessories • In Line Filter • Tire Air Chuck • Quick Connector Sets (various sizes) • Air Pressur e Regulators • Oil Fog Lubricators • Air Hose: ...

  • Craftsman 919.7255 - page 10

    10- ENG D24445 Assemble Wheels It will be necessary to brace or support one side of the outfit when installing the wheels because the compressor will have a tendency to tip. 1. Attach wheels with shoulder bolts and nuts as shown. 2. Tighten securely . NOTE : The outfit will sit level if the wheels are pr operly installed. The wheels and handle do n ...

  • Craftsman 919.7255 - page 11

    11- ENG D24445 INST ALLA TION HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air . The air compressor pump and shroud ar e designed to allow ...

  • Craftsman 919.7255 - page 12

    12- ENG D24445 Extension Cords Use extra air hose instead of an extension cord to avoid voltage dr op and power loss to the motor , and to prevent overheating. If an extension cord must be used, be sure it is: • a 3-wire extension cor d that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product • in good ...

  • Craftsman 919.7255 - page 13

    13- ENG D24445 T ank Pressur e Gauge: The tank pressur e gauge indicates the reserve air pressur e in the tank. Regulator: Controls the air pr essure shown on the outlet pressur e gauge. Pull the knob out and turn clockwise to increase pr essure and counterclockwise to decr ease pressur e. When the desired pr essure is reached push knob in to lock ...

  • Craftsman 919.7255 - page 14

    14- ENG D24445 Cooling System (not shown) : This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. Y ou know that the cooling system is working when air is being expelled. Air Compressor Pump (not s ...

  • Craftsman 919.7255 - page 15

    15- ENG D24445 How to Start: 1. T ur n the On/Auto/Off lever to “AUTO” and allow tank pressur e to build. Motor will stop when tank pressur e reaches “cut-out” pressur e. 2. Pull the regulator knob out and turn clockwise to increase pressur e. When the desired pressur e is reached push knob in to lock in place. The compressor is ready for u ...

  • Craftsman 919.7255 - page 16

    16- ENG D24445 MAINTENANCE Customer Responsibilities Daily or after each use Before each use ● ● ● Every 40 hours Every 100 hours Y early ● 1 1- more fr equent in dusty or humid conditions Check Safety V alve Drain T ank Air Filter NOTE: See “Operation” section for the location of controls. T o ensure ef ficient operation and longer lif ...

  • Craftsman 919.7255 - page 17

    17- ENG D24445 6. After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE : If drain valve is plugged, release all air pr essure. The valve can then be removed, cleaned, the reinstalled. Air Filter - Inspection and Replacement Hot surfaces. Risk of burn. Compressor heads ar e exposed when filt ...

  • Craftsman 919.7255 - page 18

    18- ENG D24445 7. Unscrew the check valve (turn counterclockwise) using a 7/8” open end wrench. Note the orientation for reassembly . 8. Using a screwdriver , carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds the valve disc in the closed position, if not the check valve needs to ...

  • Craftsman 919.7255 - page 19

    19- ENG D24445 6. Assemble the regulator and orient as shown. NOTE: Arrow indicates flow of air . Make sure it is pointing in the direction of air flow . 7. Reapply pipe sealant to outlet pressur e gauge and quick connect. 8. Reassemble outlet pressur e gauge and quick connect. Orient outlet pressur e gauge to read correctly . Tighten quick connect ...

  • Craftsman 919.7255 - page 20

    20- ENG D24445 STORAGE Before you stor e the air compressor , make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to “OFF”. 3. T ur n the regulator counterclockwise and set the outlet pressur e to zero. 4. Remove the ai ...

  • Craftsman 919.7255 - page 21

    21- ENG D24445 TROUBLESHOOTING Performing repairs may expose voltage sour ces, moving parts or compressed air sour ces, moving parts or compressed air sour ces. Personal injury may occur . Prior to attempting any repairs, unplug the air compr essor and bleed off all air tank air pressur e. PROBLEM CAUSE CORRECTION Pressur e switch does not shut off ...

  • Craftsman 919.7255 - page 22

    22- ENG D24445 PROBLEM CAUSE CORRECTION It is normal for “some” pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the “Description of Operation” paragraph in the “Operation Section. NOTE: Adjust the regulated pressur e under flow condi ...

  • Craftsman 919.7255 - page 23

    23- ENG D24445 Regulator will not shut off air outlet. Damaged regulator Replace PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit br eaker tripped. 1. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit br eaker with higher rating than that specified for your particular branc ...

  • Craftsman 919.7255 - page 24

    HOW TO ORDER REP AIR P ARTS Model No. 919.725500 Sold by Sears Canada, Inc. T oronto, Ont. M5B 2B8 SERVICE OWNERS MANUAL FOR PERMANENTL Y LUBRICA TED 2-ST AGE, TWIN V , POR T ABLE AIR COMPRESSOR The model number of your Sears Air Compressor can be found on the maintenance label on the top of the shroud or on the bar code label on the rear of the ai ...

  • Craftsman 919.7255 - page 25

    Guide de l’utilisateur Compr esseur d'air double portatif à deux étages et à lubrification permanente • Mesures de sécurité • Assemblage • Fonctionnement • Entretien • Entretien et Réglage • Guide de dépannage • Pièces de rechange Modèle nº 919.725500 V endu par Sears Canada, Inc. T oronto, Ont. M5B 2B8 D24445 Rév . ...

  • Craftsman 919.7255 - page 26

    2- FR D24445 GARANTIE COMPLÈTE DE UN AN SUR LES COMPRESSEURS D’AIR Ce compresseur d’air est garanti contr e tout défaut de fabrication pour une période de un an, à compter de la date d’achat. Au cours de cette période de garantie, SEARS S’ENGAGE À LE RÉP ARER SANS FRAIS. IL SUFFIT DE LE RETOURNER AU CENTRE DE SERVICE APRÈS-VENTE SEA ...

  • Craftsman 919.7255 - page 27

    3- FR D24445 T ABLEAU DES SPÉCIFICA TIONS Modèle no : 919-725500 Alésage 1 7/8 po (4,76 cm) Course du cylindre 1 1/4 po (3,175 cm) T ension – phase unique 120 Exigence minimale du circuit de dérivation 15 a Genre de fusible à retar dement à élément double Capacité du réservoir d’air 12 gal. (É.-U.) (45,4 L) Pression d’enclenchement ...

  • Craftsman 919.7255 - page 28

    4- FR D24445 RISQUE D’EXPLOSION OU D’INCENDIE PRÉVENTION RISQUE DANGER LES ÉTINCELLES QUI PROVIENNENT DES CONT ACTS ÉLECTRIQUES DU MOTEUR ET DU MANOST A T SONT CONSIDÉRÉES NORMALES. SI DES ÉTINCELLES ÉLECTRIQUES DU COMPRESSEUR ENTRENT EN CONT ACT A VEC DES V APEURS INFLAMMABLES, ELLES PEUVENT S’ENFLAMMER, PROVOQUANT UN INCENDIE OU UNE ...

  • Craftsman 919.7255 - page 29

    5- FR D24445 RISQUE D’ÉCLA TEMENT RÉSERVOIR D’AIR : LES CONDITIONS SUIV ANTES PEUVENT AFF AIBLIR LES P AROIS DU RÉSERVOIR ET PROVOQUER UNE EXPLOSION VIOLENTE DU RÉSERVOIR QUI RISQUE DE CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES GRA VES. 1. LE DÉFAUT DE VIDANGER DE F AÇON APPROPRIÉE L ’EAU CONDENSÉE DANS LE RÉSERVOIR RISQU ...

  • Craftsman 919.7255 - page 30

    6- FR D24445 DANGER RISQUE DE CHOC ÉLECTRIQUE NE JAMAIS F AIRE FONCTIONNER LE COMPRESSEUR À L ’EXTÉRIEUR LORSQU’IL PLEUT OU DANS DES CONDITIONS HUMIDES. NE JAMAIS F AIRE FONCTIONNER LE COMPRESSEUR SANS LES COUVERCLES DE PROTECTION OU LORSQUE CEUX-CI SONT ENDOMMAGÉS. TOUT CÂBLAGE ÉLECTRIQUE OU TOUTE RÉP ARA TION REQUIS SUR CET APP AREIL D ...

  • Craftsman 919.7255 - page 31

    7- FR D24445 RISQUE DE BRÛLURES LE F AIT DE TOUCHER AUX SURF ACES DE MÉT AL EXPOSÉES TELLES QUE LA TÊTE DU COMPRESSEUR OU LES TUBES DE SORTIE PEUT CAUSER DE GRA VES BRÛLURES À LA PEAU. NE JAMAIS TOUCHER AUX PIÈCES DE MÉT AL EXPOSÉES DU COMPRESSEUR DURANT OU IMMÉDIA TEMENT APRÈS LE FONCTIONNEMENT . LE COMPRESSEUR DEMEURE CHAUD PENDANT PLU ...

  • Craftsman 919.7255 - page 32

    8- FR D24445 DANGER RISQUE D'UNE UTILISA TION DANGEREUSE UNE UTILISA TION DANGEREUSE DE VOTRE COMPRESSEUR D'AIR POURRAIT CAUSER DES BLESSURES GRA VES OU LA MORT DE L'UTILISA TEUR OU D'AUTRES PERSONNES. PRÉVENTION RISQUE LISEZ A TTENTIVEMENT TOUS LES INSTRUCTIONS ET LES A VERTISSEMENTS FIGURANT DANS CE GUIDE. F AMILIARISEZ-VOUS ...

  • Craftsman 919.7255 - page 33

    9- FR D24445 LEXIQUE V euillez vous familiariser avec ces termes avant d'utiliser l'appareil. CFM : pieds cubes par minute (pi 3 /min) . SCFM : pieds cubes par minute (pi 3 /min) standard. Une unité de mesur e de débit d'air . PSIG: jauge indiquant le nombre de livr es par pouce carré (lb/po 2 ). Une unité de mesure de pression. ...

  • Craftsman 919.7255 - page 34

    10- FR D24445 Assemblage des roues Il s'avérera nécessaire de supporter un côté de l'appareil lors du montage des r oues parce que le compr esseur d'air aura tendance à basculer . 1. Attachez les roues avec les boulons à épaulement et les écrous, tel qu'illustré. 2. Serrez bien les pièces. REMARQUE : L'appareil se ...

  • Craftsman 919.7255 - page 35

    11- FR D24445 2. Assur ez-vous que la prise de courant utilisée a la même configuration que la fiche de mise à la terre. NE P AS UTILISER UN ADAPT A TEUR . V oir l'illustration. 3. Inspectez la fiche et le cor don avant chaque utilisation. Ne pas les utiliser s'il y a des signes de dommages. 4. Si vous ne compr enez pas tout à fait ce ...

  • Craftsman 919.7255 - page 36

    12- FR D24445 Rallonges Utilisez un boyau d'air supplémentaire au lieu d'une rallonge pour éviter une chute de tension, une perte de puissance et la surchauf fe du moteur . Si une rallonge doit être utilisée, s'assur er : • d'utiliser une rallonge à trois fils, munie d'une fiche à trois lames avec mise à la terre e ...

  • Craftsman 919.7255 - page 37

    13- FR D24445 Régulateur : Le régulateur contrôle la pression d'air indiqué sur le manomètr e de sortie. Tirez le bouton et tournez-le dans le sens des aiguilles d'une montre pour augmenter la pression et dans le sens contraire pour réduir e la pression. Une fois que la pression désirée est atteinte, poussez le bouton pour le verr ...

  • Craftsman 919.7255 - page 38

    14- FR D24445 Avant le démarrage Procédur es de rodage Le compresseur d'air peut subir d'importants dom- mages si les procédur es de rodage ne sont pas suivies à la lettre. Cette procédur e doit être exécutée avant d'utiliser le compresseur d'air pour la premièr e fois et après le remplacement de la soupape de retenue ...

  • Craftsman 919.7255 - page 39

    15- FR D24445 4. Placez le levier "On/Auto/Off" à la position "ON/AUTO". Le compresseur se mettra en mar che. 5. Faire fonctionner le compr esseur pendant 15 minutes. Assurez-vous que le robinet de vidange est ouvert et que la pression d'air accumulée dans le réservoir est minimale. 6. Après 15 minutes, fermez le robine ...

  • Craftsman 919.7255 - page 40

    16- FR D24445 ENTRETIEN Responsabilités du client ● ● ● ● 1 1- more fr equent in dusty or humid conditions Vérifier la soupape de sûreté Vidanger le réservoir Filtre à air Soupapes d'admission et d'échappementde la pompe du compresseur d'air ● À chaque jour ou après chaque utilisation À chaque tranche de 40 heures ...

  • Craftsman 919.7255 - page 41

    17- FR D24445 Filtre à air - Inspection et remplacement Surfaces chaudes. Risque de brûlures. La tête du compresseur est exposée lorsque le couvercle de filtr e est enlevé. Attendez jusqu'à ce que le compresseur soit refr oidi avant de procéder à l'entr etien. Un filtre à air sale empêchera le fonctionnement du compresseur à sa ...

  • Craftsman 919.7255 - page 42

    18- FR D24445 7. À l'aide d'une clé ouverte de 7/8 po, dévissez la soupape de retenue (en tournant dans le sens contraire des aiguilles d'une montre). REMARQUE : l'orientation pour l'assemblage plus tar d. 8. À l'aide d'un tour nevis, poussez doucement le disque de soupape vers le haut et vers le bas. REMARQUE ...

  • Craftsman 919.7255 - page 43

    19- FR D24445 6. Assemblez le régulateur et orientez-le tel qu'illustré. REMARQUE : La flèche indique le sens du débit d'air . Assurez-vous qu'elle est dirigée dans la direction du débit d'air . 7. Appliquez un produit d'étanchéité au manomètre de sortie et au raccord à connexion rapide. 8. Assemblez le manomètr ...

  • Craftsman 919.7255 - page 44

    20- FR D24445 RANGEMENT Avant de ranger le compr esseur d'air , effectuez les étapes suivantes : 1. Revoyez la section intitulée "Entretien" des pages précédentes et exécutez l'entretien r equis. 2. Placez le levier "On/Auto/Off" à la position "OFF". 3. T our nez le régulateur dans le sens contraire de ...

  • Craftsman 919.7255 - page 45

    21- FR D24445 DÉP ANNAGE En effectuant des réparations au compr esseur , il se peut que vous soyez exposé aux sources de tension, aux pièces mobiles ou aux sources d'air comprimé qui risquent de causer des blessures corpor elles. Débranchez le compresseur et purgez l'air pr essurisé du réservoir avant d'entamer toute réparat ...

  • Craftsman 919.7255 - page 46

    22- FR D24445 Une légère chute de pr ession est considérée normale. S'il y a une chute excessive de pression lorsqu'un accessoir e est utilisé, ajustez le régulateur en suivant les directives du paragraphe intitulé "Description du fonctionnement" de la section sur l'utilisation. REMARQUE : Ajustez la pression du rég ...

  • Craftsman 919.7255 - page 47

    23- FR D24445 Le régulateur ne ferme pas l'orifice de sortie d'air . Régulateur endommagé Remplacez le régulateur . PROBLÈME CAUSE CORRECTION Le moteur ne tourne pas. Interrupteur de protection contr e les surchar ges déclenché. La pression dans le réservoir est supérieure à la "pr ession d'amorçage" du manostat. ...

  • Craftsman 919.7255 - page 48

    POUR PLACER UNE COMMANDE DE PIÈCES DE RECHANGE Modèle nº 919.725500 V endu par Sears Canada, Inc. T oronto, Ont. M5B 2B8 SERVICE GUIDE DE L ’UTILISA TEUR POUR COMPRESSEUR D'AIR DOUBLE PORT A TIF À DEUX ÉT AGES ET À LUBRIFICA TION PERMANENTE Le num é ro du mod è le de votr e Compresseur d ’ air de Sears se trouve sur l ’é tiquett ...

Fabricant Craftsman Catégorie Air Compressor

Les documents que nous recevons du fabricant de l'appareilCraftsman 919.7255 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Craftsman
- manuels d’utilisations 919.7255
- fiches produit Craftsman
- dépliants
- ou étiquettes-énergie Craftsman 919.7255
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Craftsman 919.7255.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Craftsman 919.7255, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Craftsman 919.7255. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Craftsman 919.7255.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Craftsman 919.7255, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Craftsman 919.7255 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Craftsman 919.7255.

Le manuel d’utilisation complet Craftsman, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Craftsman 919.7255 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Craftsman 919.7255, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCraftsman 919.7255 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Craftsman 919.7255 - qui devraient nous aider dans les premières étapes lors de l'utilisation Craftsman 919.7255
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Craftsman 919.7255
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Craftsman 919.7255 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Craftsman 919.7255?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Craftsman 919.7255, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Craftsman 919.7255 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)