  • Omega Vehicle Security DP63000A-I - page 1

    LP0694A omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at D D P P 6 6 3 3 0 0 0 0 0 0 A A -I I D D P P 6 6 3 3 0 0 0 0 0 0 B B -I I Digita l P P anel M M eter ...

  • Omega Vehicle Security DP63000A-I - page 2

    OMEGAnet ® Online Ser vice omega.com Inter net e-mail info@omega.com Ser vicing North America: U.S.A.: One Omega Drive, P .O . Bo x 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@o ...

  • Omega Vehicle Security DP63000A-I - page 3

    3 z FOUR SELECT ABLE D.C. RANGES 200 µ A, 2 mA, 20 mA, 200 mA z MINIMUM AND MAXIMUM DISPLA Y CAPTURE z LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING z 0.48" (12.2 mm) HIGH DIGITS z OPTIONAL SETPOINT OUTPUT MODULES z OPTIONAL SERIAL COMMUNICA TIONS MODULES (RS232 or RS485) z OPERA TES FROM 9 TO 28 VDC POWER SOURCE z FRONT P ANEL OR SOFTWARE PR ...

  • Omega Vehicle Security DP63000A-I - page 4

    1. DISPLA Y : 5 digit LCD 0.48" (12.2 mm) high digits DP63000A-I : Reflective LCD with full viewing angle DP63000B-I : T ransmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module. 2. POWER : Input voltage range is +9 to +28 VDC with short c ...

  • Omega Vehicle Security DP63000A-I - page 5

    5 ADDING OPTION CARDS The DP63000 meters can be fitted with optional output cards and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below . The plug-in cards, that are sold separately , can be installed initially or at a later date. W ARNING: Disconnect all power to the unit before in ...

  • Omega Vehicle Security DP63000A-I - page 6

    WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter . All conductors should conform to the meter ’ s voltage and current ratings. All cabling should conform to appropriate standards of good installation, local codes and regulations. It is recommended that the power supplied to the meter (DC o ...

  • Omega Vehicle Security DP63000A-I - page 7

    7 4.3 INPUT WIRING CAUTION : Power input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the power input common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth ground potential. If not, hazardous voltage may be present at the ...

  • Omega Vehicle Security DP63000A-I - page 8

    8 5.0 R EVIEWING THE F RONT B UTTONS AND D ISPLAY PROGRAMMING MODE ENTR Y (SEL BUTT ON) It is recommended all programming changes be made off line, or before installation. The meter normally operates in the Display Mode. No parameters can be programmed in this mode. The Programming Mode is entered by pressing and holding the SEL button. If it is no ...

  • Omega Vehicle Security DP63000A-I - page 9

    9 6.1 MODULE 1 - S IGNAL I NPUT P ARAMETERS ( 1-INP ) P ARAMETER MENU ª « 0.02A rAN6E INPUT RANGE Select the input range that corresponds to the external signal. This selection should be high enough to avoid input signal overload but low enough for the desired input resolution. This selection and the position of the Input Range Jumper must match. ...

  • Omega Vehicle Security DP63000A-I - page 10

    Entering Code 66 will overwrite all user settings with the factory settings. The meter will display rESEt and then return to CodE 00 . Press the SEL button to exit the module. 10 6.2 MODULE 2 - S ECONDARY F UNCTION P ARAMETERS ( 2-SEC ) P ARAMETER MENU MIN DISPLA Y ENABLE USER INPUT ASSIGNMENT Select the value(s) to which the User Input Function is ...

  • Omega Vehicle Security DP63000A-I - page 11

    11 The Security Code determines the programming mode and the accessibility of programming parameters. This code can be used along with the Program Mode Lock-out ( P-Loc ) in the User Input Function parameter (Module 1). T wo programming modes are available. Full Programming mode allows all parameters to be viewed and modified. Quick Programming mod ...

  • Omega Vehicle Security DP63000A-I - page 12

    Enter the reset action of the output. See figure for details. Auto = Automatic action; This action allows the output to automatically reset off at the trigger points per the Setpoint Action shown in Setpoint Output Figures. The “on” output may be manually reset (of f) immediately by the front panel RST button or user input.The output remains of ...

  • Omega Vehicle Security DP63000A-I - page 13

    13 6.5 MODULE 5 - S ERIAL S ETUP P ARAMETERS ( 5 -S S E r ) The Serial Setup Parameters are only active when the optional RS232 or RS485 serial communications module is installed in the meter . Refer to the DP6-COM bulletin for complete details on DP63000 serial communications. P ARAMETER MENU button or user input manual reset, serial reset command ...

  • Omega Vehicle Security DP63000A-I - page 14

    PROGRAMMING QUICK OVERVIEW Press and hold SEL button to enter Programming Mode. ...

  • Omega Vehicle Security DP63000A-I - page 15

    W ARRANTY/DISCLAIMER OMEGA ENGINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’s customers ...

  • Omega Vehicle Security DP63000A-I - page 16

    Where Do I F ind Everything I Need for P rocess Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERA TURE ] Thermocouple, RTD & Thermistor Probes, Connectors, P anels & Assemblies ] W ire: Thermocouple, RTD & Thermistor ] Calibrators & Ice P oint References ] Recorders, Controllers & Process Monitors ] In ...

Fabricant Omega Vehicle Security Catégorie Camera Accessories

Les documents que nous recevons du fabricant de l'appareilOmega Vehicle Security DP63000A-I peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega Vehicle Security
- manuels d’utilisations DP63000A-I
- fiches produit Omega Vehicle Security
- dépliants
- ou étiquettes-énergie Omega Vehicle Security DP63000A-I
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega Vehicle Security DP63000A-I.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega Vehicle Security DP63000A-I, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega Vehicle Security DP63000A-I. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega Vehicle Security DP63000A-I.

Manuel d’utilisation complet de l’appareil Omega Vehicle Security DP63000A-I, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega Vehicle Security DP63000A-I par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega Vehicle Security DP63000A-I.

Le manuel d’utilisation complet Omega Vehicle Security, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega Vehicle Security DP63000A-I - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega Vehicle Security DP63000A-I, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega Vehicle Security DP63000A-I qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega Vehicle Security DP63000A-I - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega Vehicle Security DP63000A-I
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega Vehicle Security DP63000A-I
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega Vehicle Security DP63000A-I dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega Vehicle Security DP63000A-I?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega Vehicle Security DP63000A-I, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega Vehicle Security DP63000A-I il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)