Manuel d’utilisation Texas Memory Systems RAM-SAN 520

26 pages 0.78 mb
Télécharger

Aller à la page of 26

Summary
  • Texas Memory Systems RAM-SAN 520 - page 1

    Any trademarks or registered tradem arks used in this document belong to th e companies that own them. RAM-SAN TM User’s Guide Copyright © 2 003, Texas Mem ory System s, Inc. All rights are reser ved. No part of t his work m ay be reproduce d or used in any form or by any means - graphic, elect ronic or m echanical, incl uding ph otocopying , re ...

  • Texas Memory Systems RAM-SAN 520 - page 2

    Table of Contents Chapter 1 - O verview ........................................................................................................... ..................................................1-1 Chapter 2 - In stalla tion ....................................................................................................... ................. ...

  • Texas Memory Systems RAM-SAN 520 - page 3

    6.9 How to C ontact Us .......................................................................................................... ...............................................6-8 Chapter 7 – S pecifications..................................................................................................... ...................................... ...

  • Texas Memory Systems RAM-SAN 520 - page 4

    Chapter 1 - Overview The RAM-SAN TM is a hi gh-perform ance, m ulti-ported, solid-state disk. Me mory capacit y ranges from 16 gigaby tes (GB) through 128 G B in 16 GB increm ents 1 . Memory is orga nized internally in 128- bit wide words and accessed via four pa rallel memory buses that can each s ustain an aggregate bandwi dth of up to 800 megaby ...

  • Texas Memory Systems RAM-SAN 520 - page 5

    Chapter 2 - Inst allation The RAM-SAN is shipped with m emory boar ds and i nterfaces already installed. Be fore connecting t o a power su pply, please perform a preliminary inspection to check for an y signs of loos e parts, to ensure that all interfaces are still firmly position ed in place, and to check for any obvious sign s of damage. During p ...

  • Texas Memory Systems RAM-SAN 520 - page 6

    The managem ent port support s Ethernet co nnections via Te lnet. The IP address ma y be assigned autom atically using a DHCP, BOOTP or RARP se rver. The IP addres s m ay also be statically set using the ‘ ipcon fig ’ command fr om the serial port. The serial connection on the manag ement port may optionally be used to comm unicate with the RAM ...

  • Texas Memory Systems RAM-SAN 520 - page 7

    Chapter 3 - Underst anding Y our RAM-SAN 3.1 Interface Slot Numbering Each device in a RAM-SAN has a unique internal addr ess based on the physical location of th e device in the system. An interface’s port num ber can be determined by insp ecting the back of t he RAM-SAN (see Figure 1). 3.2 Inside the RAM-SAN You can open the top of the RAM-SAN ...

  • Texas Memory Systems RAM-SAN 520 - page 8

    WARNING : Please exercise caution as you hot-swap power supplies fo r t he RAM-SAN. Failure to follow these directions could result i n injury or death. I f you have a ny questions a bout this p rocedure, call Texas Mem ory System s at 713-266- 3200. 1. Turn off the power m odule that you plan to rem ove. Do not remove a hot swap power module fr om ...

  • Texas Memory Systems RAM-SAN 520 - page 9

    Figure 3 – Top-down View of RAM-SAN Internals The Front Panel Display Mounted on the front of the RAM- SAN is a front panel display (see Figur e 4). When the RAM-SAN is in op eration, the display reflects the system m emory activity. The display mon itors three things: location of m emory accesses, bus bandwidth and which interface slots cont ain ...

  • Texas Memory Systems RAM-SAN 520 - page 10

    Figure 4 – RAM-SAN Fron t Panel The RAM-SAN display cons ists of f our rows of li ghts. Each row corres ponds to one of the four R AM-SAN system busses. The top row corresponds to interface ports 0, 1, 2 and 3, the ne xt row to ports 4, 5, 6 a nd 7, the next row to ports 8, 9, 10 a nd 11, and the bottom row c orrespond s to interface ports 12, 13 ...

  • Texas Memory Systems RAM-SAN 520 - page 11

    RAM-SAN User’s Guide Texas Memory Sy stems, Inc. (Fe bruary 7, 2003 ) 3-1 ...

  • Texas Memory Systems RAM-SAN 520 - page 12

    Chapter 4 – Configuring the RAM-SAN This chapter focuses on configuring the RAM-SAN. This incl udes confi guring the Et hernet param eters, resizing LU NS, and performi ng LUN Maskin g. 4.1 The RAM-SAN Monitor The RAM-SAN is managed t hrough an interactive command tool . T he management soft ware is accessed over Etherne t or the serial port on t ...

  • Texas Memory Systems RAM-SAN 520 - page 13

    The amount of storage allocat ed to each Fibre Channel port may be changed using a simple configuration utility provided in the monitor. To enter this utility, type ‘ partition ’ on the monitor co mmand line. You should see a message similar to this one: ram-san> ram-san> partition ** RAM-SAN partitioning utility ** Total memory size: 819 ...

  • Texas Memory Systems RAM-SAN 520 - page 14

    RAM-SAN 8 Gigabyte s System Memory Fibre Channel ports 3 Gigabyte drive 1 3 Gigabyte drive HBA 1 HBA 2 HBA 3 FC21 FC21 HBA 4 2 Gigabyt e drive 3 & 4 2 4.3.2 Resizing LUNs The first step in changing t he configura tion is to resize the LUNs. Since our ne w configuration calls for three different LUNs, we need to use the ‘ r ’ command to resi ...

  • Texas Memory Systems RAM-SAN 520 - page 15

    Enter the LUN number: 1 Enter the Fibre Channel port: 5 Command (h for help): l Enter the LUN number: 2 Enter the Fibre Channel port: 5 Command (h for help): l Enter the LUN number: 3 Enter the Fibre Channel port: 9 Command (h for help): p Enter the LUN number (1-3, default is all): <enter> LUN 1 -- 3072 Mb ports: 5 access: Open access LUN 2 ...

  • Texas Memory Systems RAM-SAN 520 - page 16

    4.3.5 Saving the Confi guration to Flash RAM The RAM-SAN has now bee n configure d to allow acc ess from four different HBAs to 3 differe nt LUNs withi n the mem ory system. To actually commit the change we have m ade, we can use the ‘ w ’ command t o save the c onfiguration i nto Flash RAM. You may also use the ‘ q ’ comman d to quit the p ...

  • Texas Memory Systems RAM-SAN 520 - page 17

    Chapter 5 – Using the Management Port The managem ent port on the RAM-SAN allows an admi nistrator to confi gure the syste m, moni tor perform ance, and diagno se problems with the system. The ‘ help ’ command displays a list of commands av ailable. The following sections prov ide a more detailed description of the commands availab le through ...

  • Texas Memory Systems RAM-SAN 520 - page 18

    5.5 history The monitor maintains a volatile command history of the last 25 commands that hav e been entered. Using the ‘ history ’ command pr ovides a lis ting of t he history. Commands m ay be e ntered usin g the ‘<’ a nd ‘>’ key s to scrol l through thi s history or the unix-like ‘!’ comman ds. The command history is volati ...

  • Texas Memory Systems RAM-SAN 520 - page 19

    5.13 status [port] The status command provides an overview of the RAM- SAN includi ng Ethernet i nformati on, memory size, and the sta te of the Fibre Channel ports. The following output shows a sample statu s screen: ram-san> status Texas Memory Systems, Inc. RAM-SAN Monitor version 1.00 Ethernet address: 00:20:c2:00:07:f1 Ethernet IP: 192.94.2 ...

  • Texas Memory Systems RAM-SAN 520 - page 20

    Chapter 6 - T roubleshooting This chapter is a quick troublesh ooting guide for the most common RAM-SA N errors. To verify basic RAM-SAN operation, please consult Chapter 5 fo r instructions on running the syst em diagnostics. Below is a short list of RA M-SAN er rors, symptoms and solutions. If this guide does not identify and correct your problem ...

  • Texas Memory Systems RAM-SAN 520 - page 21

    6.2.1 MCP21 Does Not Display Characters If nothing is displayed on the dumb terminal connected to the RAM-SAN, try the following: • Check for solid serial cable connection at bo t h the ma nagement and the debu g monito r. • Be sure that the dumb terminal is set at 9600 baud, no parity, eigh t data bits, one stop bit, no flow control and US /CR ...

  • Texas Memory Systems RAM-SAN 520 - page 22

    the memory connect or – the connector has a key t o keep the mem ory board from goin g in backwards or awkwardly. Once in pla ce, use the handl es to evenly levera ge the memory board int o the slot. • If none of the abo ve hints helped, faulty hardware may exist. Fo llow the steps in section 6.4, Finding Bad Memory, and try to pinpoin t which ...

  • Texas Memory Systems RAM-SAN 520 - page 23

    Then repeat the steps abo ve to confirm that the me mory error follow ed the suspected board to th e new board slot. Contact Texas Memory S ystems with all the inf ormatio n you have found t o begin actions to resolve the problem. 6.5 Confidence Diagnostic, DIAGMEM, Fails If the ‘ testmem ’ test produces error m essages, use section 6.4 ab ove ...

  • Texas Memory Systems RAM-SAN 520 - page 24

    power gl itches o r a serious h ardware failure . If a configuration LED stays lit after power -up, do the following: • Verify that the osc illator is firmly ins erted into its slot. Th e oscillator is loca ted in the center of th e system motherboard, b etween the connect ors for memory slot 5. T he writing on the oscill ator should be oriented ...

  • Texas Memory Systems RAM-SAN 520 - page 25

    Chapter 7 – S pecifications This chapter contains system specificatio ns for the RAM-S AN. 7.1 Physical Characteristics Rack Mount Size: 7U (12.2”) x 25” deep Weight: 90 lbs. Voltage: 110/220 VAC Ventilation: Side to side airflow 7.2 Operating Environment Temperature: 32-85 ° F (0-30 ° C) Max relati ve hum idity: 80% (non-conde nsing) Max h ...

  • Texas Memory Systems RAM-SAN 520 - page 26

    RAM-SAN User’s Guide Texas Memory System s, Inc. (February 7, 2003) i ...

Fabricant Texas Memory Systems Catégorie Power Supply

Les documents que nous recevons du fabricant de l'appareilTexas Memory Systems RAM-SAN 520 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Texas Memory Systems
- manuels d’utilisations RAM-SAN 520
- fiches produit Texas Memory Systems
- dépliants
- ou étiquettes-énergie Texas Memory Systems RAM-SAN 520
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Texas Memory Systems RAM-SAN 520.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Texas Memory Systems RAM-SAN 520, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Texas Memory Systems RAM-SAN 520. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Texas Memory Systems RAM-SAN 520.

Manuel d’utilisation complet de l’appareil Texas Memory Systems RAM-SAN 520, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Texas Memory Systems RAM-SAN 520 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Texas Memory Systems RAM-SAN 520.

Le manuel d’utilisation complet Texas Memory Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Texas Memory Systems RAM-SAN 520 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Texas Memory Systems RAM-SAN 520, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lTexas Memory Systems RAM-SAN 520 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Texas Memory Systems RAM-SAN 520 - qui devraient nous aider dans les premières étapes lors de l'utilisation Texas Memory Systems RAM-SAN 520
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Texas Memory Systems RAM-SAN 520
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Texas Memory Systems RAM-SAN 520 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Texas Memory Systems RAM-SAN 520?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Texas Memory Systems RAM-SAN 520, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Texas Memory Systems RAM-SAN 520 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)