    Model(indoor/outdoor): FRS09PYW1/FRS09PYC1 FRS12PYW1/FRS12PYC1 FRS184YW2/FRS184YC2 FRS18PYW2/FRS18PYC2 FRS224YW2/FRS224YC2 FRS22PYW2/FRS22PYC2 a c . e r i a d i g i r f . w w w m o c . e r i a d i g i r f . w w w All a bout th e I n s t a l l a t i o n of y ou r S p l i t T y p e R o o m A i r C o n d i t i o n e r 7 6 5 1 - 2 4 9 - 6 6 8 - 1 a d a ...

  • Frigidaire FRS09PYW1 - page 2

    Safety precautions 04 Safety precautions DANGER! Avoid Serious Injury This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. or Death 1. Do not attempt to install the split air conditioner by yourself. 2. This air con ...

  • Frigidaire FRS09PYW1 - page 3

    T o prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. 1. Connect with the power properly . Otherwise, it may cause electric shock or fire due to excess h ...

  • Frigidaire FRS09PYW1 - page 4

    operation. It may cause electric removed, do not touch the metal parts of the unit. It may cause an injury . shock or injury. and electric shock. It may cause failure of appliance 11.Do not open the unit during 13.Do not disassemble or modify unit. 14.When the air filter is to be switch off , and turn off the circuit breaker . Do not clean unit whe ...

  • Frigidaire FRS09PYW1 - page 5

    Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install 2. Sites with a high concentration of salinity , such as coastal areas. 3. Sites with sulfuric gas, such as hot water springs. 4. Sites with high frequency equipment, such as wireless equipment, welding machines and medical installati ...

  • Frigidaire FRS09PYW1 - page 6

    Outdoor Unit 1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. There must not be the possibility of increased noise and vibration at the site. 4. The unit must be i ...

  • Frigidaire FRS09PYW1 - page 7

    ...

  • Frigidaire FRS09PYW1 - page 8

    Attention 1. This illustration is for explanation purposes only . 4 3 1 Indoor unit Outdoor unit 5 6 Air filter More A B C 2. Copper tubes must be insulated independently More than 6.6' More than 1' More than 1.65 ' than 1.65' More than 6 " More than 6" More than 6 " 2 6 8 7 P arts list 10 ...

  • Frigidaire FRS09PYW1 - page 9

    1.58'' 7.91'' 5.31'' 1.58'' A B (A:33.31" B:10.83") =18000 Btu's (A:36.97" B:11.73") Indoor unit outline Installation plate the ceiling from the wall from the wall Refrigerant pipe 6" or more fr om 6 " or more hole (right) Ø 2.56" 6 " or more 3.39 " 4.21 &quo ...

  • Frigidaire FRS09PYW1 - page 10

    Indoor unit installation Attention Fixing the Installation Plate Drilling the Hole 1. Install the installation plate horizontally over the structural parts on the wall using the spaces indicated on the plate, as shown 2. In the case of tiled, concrete or diameter holes. Place anchorage supports for the appropriate assembly screws. 3. F ix the insta ...

  • Frigidaire FRS09PYW1 - page 11

    Connective pipe and drainage installation Drainage 1. Run the drain hose sloping downward. Do not install the drain 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack. Connective pipe 1. F or the left -hand and right-hand piping , remove the pipe cover fr ...

  • Frigidaire FRS09PYW1 - page 12

    Attention Piping and wrapping 1. Bundle the tubing , connecting cable, and drain hose with tape 2. Because the condensed water from rear of the indoor unit is gathered in ponding box and is anything else in the box. 1. Connect the indoor unit first, then the outdoor unit. 2. Do not allow the piping to let out from the back of the indoor unit. 3. Be ...

  • Frigidaire FRS09PYW1 - page 13

    1. Install the outdoor part of the unit on a rigid surface to avoid excess noise and vibration. 2. Direct the air vent toward an area without obstacles. especially in areas where it is frequently windy . 4. If the installation site is exposed to heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protectiv ...

  • Frigidaire FRS09PYW1 - page 14

    Settlement of outdoor unit Anchor the outdoor unit tightly and horizontally on a concrete or rigid Air inlet Air inlet Air outlet $ % mount with a bolt and nut 0.39" or  A  ft) B ( f t) Outdoor unit dimension ft(WxHxD) [[ [[  ? ...

  • Frigidaire FRS09PYW1 - page 15

    Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct flaring work using the following procedure: 1. Cut the pipes and the cable. A) Use the piping kit accessory or pipes purchased locally . B) Measure the distance between the indoor and the outdoor unit. C) Cut the pipes a little longer than the me ...

  • Frigidaire FRS09PYW1 - page 16

    4. Flaring work. die in the dimension shown in the table below . OUTER Connection Adjustment 1. Align the pipes to be connected. OUTER TIGHTENING Caution: Excessive twisting may br eak the nut, depending on the installation conditions. R efrigerant piping connection Bar pipe Handle Clamp handle Y oke Red arrow mark Flare nut Pipings Indoor unit tub ...

  • Frigidaire FRS09PYW1 - page 17

    Operating Voltage (Min/Max) RLA LRA FLA HP Output Watts Volts FLA HP Output Watts 9K 115-1-60 ǂ 103/127 16.03 26 0.17 0.04 30 115V-AC 0.38 0.03 20 22 12K 115-1-60 ǂ 103/127 17.53 26 0.17 0.04 30 115V-AC 0.38 0.03 20 23 18K 208/230-1-60 ǂ 187/253 11.54 41 0.62 0.08 60 208/230V-AC 208/230V-AC 0.25 0.03 20 16 21.5K 208/230-1-60 ǂ 187/253 11.71 41 ...

  • Frigidaire FRS09PYW1 - page 18

    1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw . 4. Ensure the colour of wires of outdo ...

  • Frigidaire FRS09PYW1 - page 19

    1. ...

  • Frigidaire FRS09PYW1 - page 20

    1. Never fail to have an individual power circuit specifically for the air conditioner . As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover . liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fas ...

  • Frigidaire FRS09PYW1 - page 21

    Air purging with vacuum pump 1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves ...

  • Frigidaire FRS09PYW1 - page 22

    Air purging 24 V acuum pump Charge hose Manifold valve -76cm/Hg Charge hose Handle Lo Handle Hi Outdoor unit Indoor unit When using the vacuum pump F or method of u s ing a manifold valve, refer to it s operation manual. manifold valve. evacuate. After s tarting evacuation, s lightly loo s e the flare nut of the Lo valve on the ga s pipe s ide and ...

  • Frigidaire FRS09PYW1 - page 23

    Electrical safety P erform the electric safe ty check after completing installation: Gas leak check Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of th e piping. If bubbles come out, the pipes have Leak detect ...

  • Frigidaire FRS09PYW1 - page 24

    T est running P erform test operation after completing gas leak check at the flare nut connections and electrical safety check. 1. Connect the power , press the ON/OFF button on the remote controller to turn the unit on. cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken. Manual operation is used onl ...

  • Frigidaire FRS09PYW1 - page 25

    1. Contact a specialist to install the device. 2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms. 3. Before operating the air conditioner , ensure that the air filter is installed correctly . 4. If the unit has been out of use for a long period of time, it is recommended that the air filte ...

Fabricant Frigidaire Catégorie Yard Vacuum

Les documents que nous recevons du fabricant de l'appareilFrigidaire FRS09PYW1 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Frigidaire
- manuels d’utilisations FRS09PYW1
- fiches produit Frigidaire
- dépliants
- ou étiquettes-énergie Frigidaire FRS09PYW1
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Frigidaire FRS09PYW1.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Frigidaire FRS09PYW1, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Frigidaire FRS09PYW1. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Frigidaire FRS09PYW1.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Frigidaire FRS09PYW1, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Frigidaire FRS09PYW1 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Frigidaire FRS09PYW1.

Le manuel d’utilisation complet Frigidaire, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Frigidaire FRS09PYW1 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Frigidaire FRS09PYW1, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFrigidaire FRS09PYW1 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Frigidaire FRS09PYW1 - qui devraient nous aider dans les premières étapes lors de l'utilisation Frigidaire FRS09PYW1
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Frigidaire FRS09PYW1
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Frigidaire FRS09PYW1 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Frigidaire FRS09PYW1?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Frigidaire FRS09PYW1, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Frigidaire FRS09PYW1 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)