    VF4000-CHN-2 VF4000-CHP-2 VF4000-CMN-2 VF4000-CMP-2 US Portland Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T T O D O I F Y OU SME LL GAS • Donottrytolightanyappliance. • Do not touch any electrical switch; do not use any ...

  • Superior VF4000-CMP-2 - page 2

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 These heaters are manually controlled. Models VF4000-CMN-2 and VF4000-CMP-2 feature a gas valve incorporating a millivolt operating system. A spark ignition system (piezo) allows the heater pilot gas to be lit without the use of matches or batteries and permits operation of the heater during a power ...

  • Superior VF4000-CMP-2 - page 3

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immedi- ately. Turn off the gas supply to the heater and have it serviced by a qualified professional, as it may not be operat ...

  • Superior VF4000-CMP-2 - page 4

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 Your options are: a. Rework equations adding the space of ad- joining room(s). If the extra volume provides an unconfined space, then remove door or add ventilation grills between rooms. Refer to National Fuel Gas Code, ANSI Z223.1 1992, Section 5.3. b. Vent room directly to the outdoors. Refer to N ...

  • Superior VF4000-CMP-2 - page 5

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 Ensure the minimum clearances shown in Figures 2 and 3 are maintained. Minimum clearance to combustibles are: Appliance: side and back - 0" floor - 0" adjacent wall - 6" ceiling - 37-1/2” (953 mm) Figure 2 A hearth extension is not required with this appliance. If a hearth extension ...

  • Superior VF4000-CMP-2 - page 6

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 The gas control valve is located in the lower control compartment. To access the valve open the lower control compartment door ( Figure 9 ). The regulator has a 3/8" NPT thread inlet port and is fitted with a 3" (76 mm) long nipple, ³⁄₈ " NPT on both ends. Plan the connections ac ...

  • Superior VF4000-CMP-2 - page 7

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Figure 12 White (Supply) Black (Supply) Bipolar T erminal Screw Blower (Lower) Outlet Black Wire Mating Connectors Red Wire 120 Vac 60 Hz Blower Wiring Diagram } OFF/ON Blower Wall Switch T o Fuse or Circuit Breaker 120V AC 60Hz Fireplace Junction Box Black White Receptacle Ground Wire Connection No ...

  • Superior VF4000-CMP-2 - page 8

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Figure 14 Note: The heater may be installed directly on a floor made of standard combustible wood con- struction materials. Do not install the heater directly on carpeting or other soft floor cover- ing such as vinyl tile or flooring materials. Use a wood or metal panel that extends the full width a ...

  • Superior VF4000-CMP-2 - page 9

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 To light the burner; rotate the gas valve control knob counterclockwise to the “ON” position. Step 14. Installing the Hood Assembly – Attach the hood assembly over the firebox opening with three (3) screws. Step 15. Installing the Screen Assembly – Position the screen assembly in front of th ...

  • Superior VF4000-CMP-2 - page 10

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 Grounded to Appliance Blower Motor Motor Plug Receptacle 120V Appliance Junction Box Figure 20 Brass Louver Kit Brass louvers are available for use with these appliances. These louvers are designed to replace the standard black louvers that are provided with the appliance. The brass louver kit incl ...

  • Superior VF4000-CMP-2 - page 11

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 OPERATION AND CARE OF YOUR APPLIANCE 1. Blower operation may be controlled through the ON/OFF unit rocker switch, located in the lower control compartment. 2. These heater rated units are equipped with a two stage (HI, LOW) gas control valve. To set the burner at the HI and LOW settings, rotate the ...

  • Superior VF4000-CMP-2 - page 12

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Gas Flex Line Kit FFGC Refractory Liner Kit VF5RLK Decorative Volcanic Stone FDVS Wood Surround-Wall SUR-5PW Wood Surround-Corner SUR-5PC Brass Louver Kit BRLK-5C BSK-5 Brass Surround Kit BRLK-CS Square Trim Kit STK-5-4 Remote Control RCL Rocker Sw ...

  • Superior VF4000-CMP-2 - page 13

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 VF4000 SPECIFICATIONS Figure 21 37" (940 mm) 36" (914 mm) 30" (762 mm) 31-1/2" (800 mm) 15" (381 mm) Front View Left Side View (Right Side View - Opposite) Gas Line Opening J Box Opening 8" (203 mm) 3-3/4" (95 mm) 3-1/2" (89 mm) T op View 27" (686 mm) 36 ...

  • Superior VF4000-CMP-2 - page 14

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 VF4000-CHM/P OPERATING INSTRUCTIONS (STANDARD VALVES) FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Make sure manual shut-off valve is fully open. 3. Locate gas control knob and piezo. 4. Depress control knob in and turn clockwise to the ? ...

  • Superior VF4000-CMP-2 - page 15

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 Figure 22 Pilot Location Figure 23 Pilot Turn Control Knob to “OFF” Position Figure 24 Turn Control Knob to “IGN” Position O F F I G N L O W H I O F F I G N L O W H I ...

  • Superior VF4000-CMP-2 - page 16

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 VF4000-CMN/P OPERATING INSTRUCTIONS (MILLIVOLT VALVES) FOR YOUR SAFETY READ BEFORE LIGHTING • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. • If your gas supplier cannot be reached, call the fire department. C. Use only your hand to pus ...

  • Superior VF4000-CMP-2 - page 17

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position. 5. When igniter button is pressed, there is spark at ODS/pilot, but no ignition. 6. ODS/pilot ...

  • Superior VF4000-CMP-2 - page 18

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 18 R EP L AC E M EN T P AR TS  L IS T I te m N o. D e sc r i pt i on V F4 0 00 - C HN  (M a n ua l ) V F4 0 00 - C HP  (M a n ua l ) V F4 0 00 - C MN  (M i l li v o lt ) V F4 0 00 - C MP  (M i l li v o lt ) P ar t N o . Q ty . Pa r t N o. Q ty . 1 . V ...

  • Superior VF4000-CMP-2 - page 19

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 REPLACEMENT PARTS 9 10 15 14 4 7 6 5 12 1 12 13 13 2 8 3 CH Models CM Models CH Models CM Models (SIT Valve Shown) 11 ...

  • Superior VF4000-CMP-2 - page 20

    NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 Printed in U.S.A. © 1997 by Lennox Hearth Products P/N 903590 REV. P 04/2010 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications and prices, and also to discontinue colors, styles and products. Consult your local distributor f ...

Fabricant Superior Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilSuperior VF4000-CMP-2 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Superior
- manuels d’utilisations VF4000-CMP-2
- fiches produit Superior
- dépliants
- ou étiquettes-énergie Superior VF4000-CMP-2
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Superior VF4000-CMP-2.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Superior VF4000-CMP-2, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Superior VF4000-CMP-2. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Superior VF4000-CMP-2.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Superior VF4000-CMP-2, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Superior VF4000-CMP-2 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Superior VF4000-CMP-2.

Le manuel d’utilisation complet Superior, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Superior VF4000-CMP-2 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Superior VF4000-CMP-2, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSuperior VF4000-CMP-2 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Superior VF4000-CMP-2 - qui devraient nous aider dans les premières étapes lors de l'utilisation Superior VF4000-CMP-2
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Superior VF4000-CMP-2
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Superior VF4000-CMP-2 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Superior VF4000-CMP-2?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Superior VF4000-CMP-2, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Superior VF4000-CMP-2 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)