    Part No. D20324-011-2 Single-Stage Oillube Compr essor Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference. Model No. T ype Serial No. ESP AÑOL: PÁGINA 27 FRANÇAIS: ...

  • Porter-Cable CPLC7060V - page 2

    2-ENG CAUTION indicates a potentially hazar dous situation which, if not avoided, may result in minor or moderate injury . This manual contains information that is important for you to know and understand. This infor - mation relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS . T o help you recognize this information, we use the sy ...

  • Porter-Cable CPLC7060V - page 3

    3-ENG RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONT ACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SP ARK. IF ELECTRICAL SP ARKS FROM COMPRESSOR COME INTO CONT ACT WITH FLAMMABLE V APORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEA TING AND COULD CAUSE FIRE. UNA TT ...

  • Porter-Cable CPLC7060V - page 4

    4-ENG RISK FROM FL YING OBJECTS IMPORT ANT SAFETY INSTRUCTIONS (cont’d) THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT , CHIPS, LOOSE P ARTICLES AND SMALL OBJECTS A T HIGH SPEED , RESUL TING IN PROPERTY DAMAGE OR PERSONAL INJUR Y . AL WA YS WEAR ANSI Z87.1 APPROVED SAFETY GLASSES WITH SIDE SHIELDS WHEN ...

  • Porter-Cable CPLC7060V - page 5

    5-ENG RISK FROM MOVING P ARTS RISK OF BURNS RISK OF F ALLING IMPORT ANT SAFETY INSTRUCTIONS (cont’d) WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT MOVING P ARTS SUCH AS THE PULLEY , FL YWHEEL, AND BEL T CAN CAUSE SERIOUS INJUR Y IF THEY COME INTO CONT ACT WITH YOU OR YOUR CLOTHING. A TTEM ...

  • Porter-Cable CPLC7060V - page 6

    6-ENG CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressure. ASME: American Society of Mechanical Engineers; made, tested, inspected and register ed to meet the standards of the ASME. Code Certification: Pr oducts that bear one or mor ...

  • Porter-Cable CPLC7060V - page 7

    7-ENG ON/AUTO-OFF Switch (A) Fig. 1: T u rn this switch ON to provide automatic power to the pressure switch and OFF to remove power . Pressure Switch (B) Fig. 1: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reache ...

  • Porter-Cable CPLC7060V - page 8

    8-ENG Impr oper electrical installation of this product may void its warranty and your fire insurance. Have cir cuit wiring performed by qualified personnel such as a licensed electricians who is familiar with the current national electrical code and any pr evailing local electrical codes. Location of the Air Compr essor The manifold assembly does ...

  • Porter-Cable CPLC7060V - page 9

    9-ENG Wiring Instructions (Fig. 3) Perform electrical wiring according to the following instructions: Impr oper electrical gr ounding can result in a risk of electrical shock. Wiring for the pr essur e switch AND electrical motor should be done by a licensed electrician in accor dance with national and local codes and or dinances. Install the air c ...

  • Porter-Cable CPLC7060V - page 10

    10-ENG GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK! In the event of a short circuit, grounding r educes the risk of shock by providing an escape wir e for the electric current. This air compressor must be pr operly grounded. Impr oper grounding can result in electrical shock! All grounding should be performed by a licensed electrician in accord ...

  • Porter-Cable CPLC7060V - page 11

    11-ENG 1. Refer to the Service Instructions in this manual for the specific oil r ecommended for use in your air compressor unit. 2. Remove the oil fill plug. 3. Fill the crankcase. The oil level should be even with the top of the fill hole and must not be allowed to be lower than 3/8" from the top (6 threads) at any time. 4. Replace the oil f ...

  • Porter-Cable CPLC7060V - page 12

    12-ENG T ypical Compressed Air Distribution System Compr essed air dryers reduce the water vapor concentration and prevent water formation in compressed air lines. Dryers ar e a necessary companion to filters, aftercoolers, and automatic drains for impr oving the pr oductivity of compressed air systems. W ater and water vapor r emoval increases the ...

  • Porter-Cable CPLC7060V - page 13

    13-ENG BREAK-IN PROCEDURES This pr ocedure is r equir ed before the air compressor is put into service, befor e the hose is installed, the check valve is r eplaced, or a complete compressor pump is replaced. Serious damage may result if the following break-in instructions ar e not closely followed. The pr ocedure: 1. Make sur e the pressure switch ...

  • Porter-Cable CPLC7060V - page 14

    14-ENG Unit cycles automatically when power is on. During maintenance, you could be exposed to voltage sources, compressed air , moving parts, or hot surfaces. Personal injuries can occur . Unplug the unit and bleed off all air tank pressur e and allow unit to cool befor e doing any maintenance or repair . Never operate the unit with the belt guard ...

  • Porter-Cable CPLC7060V - page 15

    15-ENG Every 160 Hours of Operation: 1. Check drive belt tension; adjust if necessary . 2. Inspect air lines and fittings for leaks; correct as necessary . 3. Check the alignment of the motor pulley to the flywheel. If necessary , align to within 1/32 inch on center line. Each Y ear of Operation or if a Problem is Suspected: Check condition of air ...

  • Porter-Cable CPLC7060V - page 16

    16-ENG Check V alve - Inspection and Replacement Remove and inspect the check valve at least once a year or more often if the air compr essor is heavily used. Moisture and other contaminants in the hot compr essed air will cause an accumulation of a carbon-like residue on the working parts. If the valve has heavy carbon build-up, it should be r epl ...

  • Porter-Cable CPLC7060V - page 17

    17-ENG NOTE The belt must be centered over the gr ooves on the flywheel and motor pulley . 4. T o reinstall beltguar d, align the bottom tabs of the beltguar d into the slots of the base. These are located behind the ON/OFF switch. Replace beltguard screws and tighten securely . Belt Guar d - Removal and Installation 1. Remove and lock out power fr ...

  • Porter-Cable CPLC7060V - page 18

    18-ENG 2. Remove beltguard. 3. Place a straight edge (such as a ruler) against the outside of the flywheel and measure the distance from it to the nearest gr oove. Alignment is achieved when the other end of the straight edge is within 1/32” of the measured dimension at the pulley grooves. If the pulleys are not aligned: a. Loosen the motor pulle ...

  • Porter-Cable CPLC7060V - page 19

    19-ENG STORAGE OF COMPRESSOR UNIT 1. Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary . 2. T ur n the air compressor unit of f. 3. T ur n the regulator counter clockwise and set the outlet pressure to zero. 4. Remove the air tool or accessory . 5. Open the regulator or and allow the air to slowly ...

  • Porter-Cable CPLC7060V - page 20

    20-ENG CAUSE . Air leaks in air tank or at air tank welds. PERFORMING REP AIRS MA Y EXPOSE VOL T AGE SOURCES, MOVING P ARTS OR COMPRESSED AIR SOURCES. PERSONAL INJUR Y MA Y OCCUR. PRIOR TO A TTEMPTING ANY REP AIRS, UNPLUG THE AIR COMPRESSOR AND BLEED OFF ALL AIR T ANK AIR PRESSURE. PROBLEM Air tank must be replaced. DO NOT DRILL INTO, WELD, OR OTHE ...

  • Porter-Cable CPLC7060V - page 21

    21-ENG CAUSE PROBLEM CORRECTION Motor will not run. Motor overload pr otection switch has tripped. Air tank pr essure exceeds pr essure switch "cut-in pr essure". Check valve stuck open. Loose electrical connections. Possible malfunctioning capacitor . Paint spray on internal motor parts. Possible malfunctioning motor . Fuse blown, cir cu ...

  • Porter-Cable CPLC7060V - page 22

    22-ENG CAUSE PROBLEM CORRECTION Excessive belt wear . Loose belt/tight belt. Loose pulley . Adjust belt tension. (See Belt Replacement.) Check for worn keyway or pulley bore. Also check for bent motor shaft. Replace parts if necessary . (Refer to the Unit Parts Manual.) Knocking noise. Malfunctioning check valve. Loose pulley . Low oil level. Loose ...

  • Porter-Cable CPLC7060V - page 23

    23-ENG Air compressor overheating. Motor overheating. Air compr essor overworked. The outlet tube and/or check valve is restricted. Dirty air compressor . High ambient temperature. Reduce air consumption or add another air compressor to take up some of the load. Check the tube and the check valve. Clean if necessary . Clean the air compr essor thor ...

  • Porter-Cable CPLC7060V - page 24

    24-ENG ACCESSORIES Accessories can be found at the stor e from which the unit was purchased or at a local hardware store. PLUMBING COMPONENTS CONNECTORS Connects components that have similar NPT threads; Male or Female. 360 O SWIVEL CONNECTOR Eliminates hose twist and improves tool handling. ADAPTERS Combines components that have different NPT thre ...

  • Porter-Cable CPLC7060V - page 25

    25-ENG NOTES ...

  • Porter-Cable CPLC7060V - page 26

    26-ENG LIMITED WARRANTY POR TER-CABLE CORPORA TION warrants to the original purchaser that each new air compressor and service part is free fr om defects in material and workmanship and agrees to repair or replace under this warranty any defective pr oduct or part as follows fr om the original date of purchase. 5 YEARS – Limited warranty on 2-sta ...

Fabricant Porter-Cable Catégorie Air Compressor

Les documents que nous recevons du fabricant de l'appareilPorter-Cable CPLC7060V peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Porter-Cable
- manuels d’utilisations CPLC7060V
- fiches produit Porter-Cable
- dépliants
- ou étiquettes-énergie Porter-Cable CPLC7060V
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Porter-Cable CPLC7060V.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Porter-Cable CPLC7060V, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Porter-Cable CPLC7060V. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Porter-Cable CPLC7060V.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Porter-Cable CPLC7060V, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Porter-Cable CPLC7060V par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Porter-Cable CPLC7060V.

Le manuel d’utilisation complet Porter-Cable, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Porter-Cable CPLC7060V - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Porter-Cable CPLC7060V, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lPorter-Cable CPLC7060V qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Porter-Cable CPLC7060V - qui devraient nous aider dans les premières étapes lors de l'utilisation Porter-Cable CPLC7060V
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Porter-Cable CPLC7060V
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Porter-Cable CPLC7060V dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Porter-Cable CPLC7060V?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Porter-Cable CPLC7060V, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Porter-Cable CPLC7060V il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)