    • Refer to Service Manual RS6300008 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. GPH 13 M Series Multi Position Package Heat Pump Unit s with R410A RT6 ...

  • Goodman Mfg RT6332013r1 - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...

  • Goodman Mfg RT6332013r1 - page 3

    PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GPH1324M41AB G PH1330M41 AB G PH1336M41 AB G PH1342M41 AB G PH1348M41 AB G PH1360M41 AB The United States Environmental Protection Agency ( ...

  • Goodman Mfg RT6332013r1 - page 4

    4 PRODUCT DESIGN GPH13 (M Series) Package Units are designed for outdoor installations only in either residential or light commercial ap- plications and are available in 2, 2.5, 3, 3.5, 4 & 5 ton sizes. They are designed for 208/230 volt single phase applications. The connecting ductwork (Supply and Return) can be con- nected for either horizon ...

  • Goodman Mfg RT6332013r1 - page 5

    PRODUCT DESIGN 5 Outside Slab Installation -Multi-positional (M) NOTE: Roof overhang should be no more than 36" and provi- sions made to deflect the warm discharge air out from the overhang. Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency. Roo f C ur b Rooftop Installation - -Multi-posi ...

  • Goodman Mfg RT6332013r1 - page 6

    6 PRODUCT DESIGN HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE UNIT SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent pro- tection dur ...

  • Goodman Mfg RT6332013r1 - page 7

    PRODUCT DIMENSIONS 7 GPH13[24-60]M41* MEDIUM CHASSIS GPH1324M41* GPH1330M41* GPH1336M41* GPH1342M41* LARGE CHASSIS GPH1348M41* GPH1360M41* BL OWER ACCES S P ANEL ? ? 2 3 4 51 47 SUP PL Y 1 3/8 A RETUR N POW ER WI RE ENT RANCE 4 1/8 2 1/8 6 ½ 16 16 5 ½ B B CONTRO L WI RE ENT RANCE CONDEN SA TE DRAI N CONNEC TION 3 / 4” NP T FE M ALE 18 7/8 SUCT ...

  • Goodman Mfg RT6332013r1 - page 8

    P ACKAGE HEA T PUMP SPECIFICA TIONS 8 GPH13[24-36]M41AB (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs wi ...

  • Goodman Mfg RT6332013r1 - page 9

    P ACKAGE HEA T PUMP SPECIFICA TIONS 9 GPH13[42-60]M41AB (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs wi ...

  • Goodman Mfg RT6332013r1 - page 10

    ACCESSORIES 10 GPH13[24-60]M41* Par t N u mb er De scr ipti o n O T 18-60 A O utd oor Th er mosta t Ki t w/L oc k out S tat O T /EHR 18-60 Eme rgenc y Heat R el ay K i t HKR El ec tr ic Heat K i t PG C101/ 10 2/103 Roof C ur b PEHH101/ 102 Hor iz on tal Ec onom i zer For He at Pum p, Smal l and Med i um Ch ass is PEHH103 Hor iz on tal Ec onom i zer ...

  • Goodman Mfg RT6332013r1 - page 11

    BLOWER PERFORMANCE DA T A 11 NOTES: • Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. • Data shown does not include filter pressure drop, approx. 0.08” H 2 O. • ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON ...

  • Goodman Mfg RT6332013r1 - page 12

    12 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 110 1 2 0 100 13 0 140 15 0 100 90 80 70 60 50 40 30 20 10 OUT P UT B TU/ H R x 10 0 0 BT U OUTPUT vs TEMPER ATU RE RIS E CHART TEMPERAT UR E RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C F M FORMULA S BTU OUTPUT = CFM x 1.08 x RISE RISE = BTU OUTPUT 1.0 8 ÷ CFM 800 ...

  • Goodman Mfg RT6332013r1 - page 13

    13 COOLING PERFORMANCE DA T A GPH1324M41* MOD E L: GPH 1324M41 * E XP A ND E D P E RFO RM A N CE DA TA C OOL ING OP E R AT IO N Desi g n Su b co o l i ng, 10 + / - 2 ° F @ t h e li q u i d a cce ss fi tt i n g co n n ec tio n A H RI 95 t est co n d i t i o n s. D e si g n S u p er h eat 1 0 +/ - 2 ° F @ t h e co m p r ess o r s u c ti o n ac ces ...

  • Goodman Mfg RT6332013r1 - page 14

    14 COOLING PERFORMANCE DA T A GPH1324M41* M O DE L : G PH1 3 2 4 M 4 1 * E X P A ND E D P E RFO RM A N CE DA T A C OOL ING OP ER AT IO N De s i gn Subc ooli n g, 1 0 + / -2 °F @ the l i qui d a cc e ss fitting conne c ti on AH RI 95 t e s t c ondi tions. D e sign S uperhea t 1 0 + / - 2 °F @ th e co m p r ess o r suc t i on ac ces s f i t t i n g ...

  • Goodman Mfg RT6332013r1 - page 15

    15 COOLING PERFORMANCE DA T A GPH1330M41* MOD E L: GP H 1330M41* E XP A ND E D PE RF ORM A N CE DA T A C OOL I NG OP E R AT IO N De s i gn Su bc o oli n g, 10 + / -2 °F @ the l i quid a c c ess fi tt ing conn e cti on AH RI 95 t es t c ond i tions . D e sign S upe rhe a t 1 0 + /- 2 °F @ th e com p r ess o r suc ti o n ac ces s fi tti n g c on n ...

  • Goodman Mfg RT6332013r1 - page 16

    16 COOLING PERFORMANCE DA T A GPH1330M41* MOD E L : GP H 1330M41* EX PAN DE D P ER FO R M AN C E D AT A C OOLING OP E R AT IO N Desi g n Su b co o l i n g, 10 + / - 2 ° F @ t h e li q u i d a cce ss f i t t i n g co n n ec t io n AH RI 95 t est co n d i t i o n s. D e si g n S u p er h eat 1 0 +/ - 2 ° F @ th e co m p r ess o r su c ti o n ac ces ...

  • Goodman Mfg RT6332013r1 - page 17

    17 COOLING PERFORMANCE DA T A GPH1336M41* MOD E L: GP H 1336M41* EX PAN DE D P E R F O R MANC E D ATA C OOL ING OP ER AT IO N Desi g n Sub co o l i ng, 9 + /-2 °F @ th e l i q u id ac ces s fi tt i n g c o n n ect i o n A H R I 95 t e st co n d i t i ons . Des i g n S upe r h e at 7+ / -2 ° F @ th e co m p re sso r suct ion ac ces s f i tt i n g ...

  • Goodman Mfg RT6332013r1 - page 18

    18 COOLING PERFORMANCE DA T A GPH1336M41* M O DE L : G PH1 3 3 6 M4 1 * E X P A ND ED PE RF ORM A N CE DA T A C OOLING OPERAT IO N De s i gn Subc ool i n g, 9 +/ -2 ° F @ the l i qui d ac ce s s fitting c onnec tion A HRI 95 te st c onditi o ns . D e s i g n S u pe rh e at 7 + / -2 °F @ the c o m p re ssor su ct io n ac ces s fi tt i n g c o nne ...

  • Goodman Mfg RT6332013r1 - page 19

    19 COOLING PERFORMANCE DA T A GPH1342M41* MOD E L: GP H 1342M41* EX PAN DE D P ER F O R MANC E D ATA CO O L I N G O PE RA T I ON Desi g n Sub co o l i n g , 10 + / - 2 ° F @ t h e li q u i d a cce ss fi t t i n g co n n ec t ion A H RI 95 t est co n d i ti o n s. D e si g n S u p er h eat 1 0 +/ - 2 ° F @ th e c o mpr es so r s u ct i o n a cce s ...

  • Goodman Mfg RT6332013r1 - page 20

    20 COOLING PERFORMANCE DA T A GPH1342M41* MOD E L: GP H 1342M41* E XP A ND ED PE RF ORM A N CE DA T A C OOLING OP E R AT IO N Des i g n Su b co o l i n g, 10 + / - 2 ° F @ t h e li q u i d a cce ss f i tt i n g co n n ec t io n A H RI 95 t est co n d i ti o n s. D e si g n S u p er h eat 1 0 +/ - 2 ° F @ t h e c o mpr es so r s u ct i o n a cce s ...

  • Goodman Mfg RT6332013r1 - page 21

    21 COOLING PERFORMANCE DA T A GPH1348M41* MOD E L: GP H 1348M 41* E X P A ND ED PE RFORM A N CE DA T A C OOL ING OP E R AT IO N D esi g n Su b co o l i n g , 12 + / - 2 ° F @ th e li q u i d a cce ss fi tt i n g co n n ec tio n A H RI 95 t es t co n d i t i o n s . D e si g n S u p e r h e at 9 + / -2 ° F @ th e co m p r ess o r su c tio n ac ces ...

  • Goodman Mfg RT6332013r1 - page 22

    22 COOLING PERFORMANCE DA T A GPH1348M41* MOD EL: GP H 1348M 41* EX PAN DE D P ER F O R M ANC E D AT A C OOL ING OP E R AT IO N De s i gn Subc ool i n g, 12 +/ -2 °F @ the l i qui d a c c e ss fi tting conne c ti on AH RI 95 t es t c onditi ons. D e sign S uperhea t 9 + / -2 ° F @ the com p r ess o r su c t io n ac ces s f i tt i n g c o n ne cti ...

  • Goodman Mfg RT6332013r1 - page 23

    23 COOLING PERFORMANCE DA T A GPH1360M41* MOD E L: GP H 1360M41* EX PAN DE D P ER F O R MANC E D ATA C OOL ING OP E R AT IO N Des i g n Su b co o l i n g , 9 + /- 2 ° F @ th e l i q u id ac ces s fi tt i ng c o n n ecti o n A H R I 95 t e st co n d i ti o n s . D es i g n S u pe r h e at 7 + /- 2 ° F @ t h e co mpr e sso r su ct i o n acc ess f i ...

  • Goodman Mfg RT6332013r1 - page 24

    24 COOLING PERFORMANCE DA T A GPH1360M41* MOD EL: GP H 1360M 41* EX PAN DE D P E R F O R M ANC E D AT A C OOLING OP ER AT IO N D esi g n Su b co o l i n g, 9 + /- 2 ° F @ th e l i q u id ac ces s f i tt i n g c o n n ect i o n A H RI 95 te st co n d i t i on s . D es i gn S u pe r h e at 7 + /- 2 ° F @ t h e c o mp r e sso r su ct i o n acc ess f ...

  • Goodman Mfg RT6332013r1 - page 25

    25 HEA TING PERFORMANCE DA T A GPH13[24-42]M41* PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb ...

  • Goodman Mfg RT6332013r1 - page 26

    26 HEA TING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr ...

  • Goodman Mfg RT6332013r1 - page 27

    WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 27 WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES MA Y BE PRESENT . F AILURE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPH13[24-42]M41AB ...

  • Goodman Mfg RT6332013r1 - page 28

    28 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES MA Y BE PRESENT . F AILURE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPH13[48-60]M41AB ...

Fabricant Goodman Mfg Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilGoodman Mfg RT6332013r1 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Goodman Mfg
- manuels d’utilisations RT6332013r1
- fiches produit Goodman Mfg
- dépliants
- ou étiquettes-énergie Goodman Mfg RT6332013r1
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Goodman Mfg RT6332013r1.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Goodman Mfg RT6332013r1, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Goodman Mfg RT6332013r1. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Goodman Mfg RT6332013r1.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Goodman Mfg RT6332013r1, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Goodman Mfg RT6332013r1 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Goodman Mfg RT6332013r1.

Le manuel d’utilisation complet Goodman Mfg, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Goodman Mfg RT6332013r1 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Goodman Mfg RT6332013r1, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGoodman Mfg RT6332013r1 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Goodman Mfg RT6332013r1 - qui devraient nous aider dans les premières étapes lors de l'utilisation Goodman Mfg RT6332013r1
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Goodman Mfg RT6332013r1
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Goodman Mfg RT6332013r1 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Goodman Mfg RT6332013r1?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Goodman Mfg RT6332013r1, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Goodman Mfg RT6332013r1 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)