    AUTOMA TIC ENGINE CONTROLLERS MODELS A88 AND A88-F INST ALLA TION MANUAL A88-8916N Revised 01-97 Section 40 (00-02-0196) ® ...

  • Murphy Automatic Engine Controller A88 - page 2

    T ABLE OF CONTENTS SECTION P AGE I INTRODUCTION 1 II SPECIFICA TIONS 1 IIA Power Requirements 1 IIB Input Requirements 1 IIC Output Ratings 1 III FRONT P ANEL DESCRIPTION 2 IIIA Description of LED Callouts 3 IIIB Description of AOT Switch, Crank Disconnect Control & Rest/Crank T ime Control 3 IV OPTIONAL HOOKUPS 4 V OPERA TION 5 LIST OF ILLUSTR ...

  • Murphy Automatic Engine Controller A88 - page 3

    WARNING BEFORE BEGINNING INST ALLA TION OF THIS MURPHY PRODUCT ✔ Disconnect all electrical power to the machine. ✔ Make sure the machine cannot operate during installation. ✔ Follow all safety warnings of the machine manufacturer . ✔ Read and follow all installation instructions. ...

  • Murphy Automatic Engine Controller A88 - page 4

    A. The Automatic Engine Controller , Model A88 and A88-F is designed to automatically start, monitor and stop electric start engines. The A88 comes in an all-weather case with a 5 foot cable and a plug for connection. The A88-F is the same system, but housed in a panel-mount case with terminals on back for connecting. B. Features 1. Has a self-cont ...

  • Murphy Automatic Engine Controller A88 - page 5

    SECTION III: FRONT P ANEL DESCRIPTION 20s 15s 10s 5s CRANK AND REST TIME PICK UP PRESENT CRANK CRANK DISCONNECT IGNITION ON CRANK DISCONNECT OVER CRANK ENGINE TEMP. CHOKE OIL PRESSURE AUTO OFF TEST CRANK AND REST TIME IGNITION ON PICK UP PRESENT CRANK CRANK DISCONNECT CRANK DISCONNECT 20s 15s 10s 5s CHOKE OVER CRANK OIL PRESSURE ENGINE TEMP. AUTO O ...

  • Murphy Automatic Engine Controller A88 - page 6

    FRONT P ANEL DESCRIPTION Along with each description, an attempt has been made to clarify output and input connections according to their functions and terminals or wire color . A. Description of LED Callouts 1. IGNITION The ignition LED will come on when the system receives a signal to start. If the alarm before start is used, this ignition LED wi ...

  • Murphy Automatic Engine Controller A88 - page 7

    In this section the terms Sink and Source are used. Sink: This terms refers to an output that switches to ground to do work. Source: This term will be used to refer to an output that is switched to positive to do work. 1. CHOKE T o use this feature, connect the choke or compression release solenoid to the battery positive and then to the terminal o ...

  • Murphy Automatic Engine Controller A88 - page 8

    Refer to Diagrams 1 and 3: Basic Wiring Hookup for correct connections to your engine. Diagram 2 shows wire colors that correspond to the A88 plug and hookup wire, in the event of two colors the first color is the primary color and the other is a tracer color . Diagram 4 identifies the A88-F wiring terminals. Step No. 1, Pickup: Determine the type ...

  • Murphy Automatic Engine Controller A88 - page 9

    123 Grey Blue White/Black Green White/Red White/Brown Yellow Brown Green/White Brown/White Grey/White Red/White White White/Orange White/Yellow Violet/White Orange Red/White ground for 5 seconds Alarm On Start Connect SPST For Momentary Type Operation Close to Run Open to Stop Ignition Connection Breaker Type, 6 amp max Ignition Connection CDI Type ...

  • Murphy Automatic Engine Controller A88 - page 10

    7 Pin 1-wire-Wht/Blk: Breaker ignition I/P Pin 2-wire-Green: Vacuum switch I/P Pin 3-wire-Viol/Wht: Grnd for time delay I/P Pin 4-wire-Grey: Magnetic pickup I/P Pin 5-wire-Blue: Tach alternator I/P Pin 6-wire-Violet: Choke (sink) O/P Pin 7-wire-Wht/Red: Crank (sink) O/P Pin 8-wire-Yellow: Engine running (sink) O/P Pin 9-wire-Grn/Wht: Start I/P Pin ...

  • Murphy Automatic Engine Controller A88 - page 11

    8 123 6 7 5 8 2 1 18 20 4 17 16 15 23 21 22 9 19 Ground for 5 seconds Alarm On Start Connect SPST For Momentary T ype Operation Close to Run Open to Stop Ignition Connection Breaker T ype, 6 amp max Ignition Connection CDI T ype 6 amp max Ground to Kill Stop 16 No Connection Ground for 5 seconds Alarm On Start V acuum Switch Solenoid Switched to Gr ...

  • Murphy Automatic Engine Controller A88 - page 12

    Terminal 1: Crank (source) Diagram 4: A88-F Wiring Terminals Terminal 2: Crank (sink) Terminal 3: Choke (sink) Terminal 4: Start I/P Terminal 5: Breaker ignition I/P Terminal 6: Magnetic pickup I/P Terminal 21: Common Terminal 22: Normally Closed (N.C.) Terminal 23: Normally Open (N.O.) Terminal 24: No Connection Terminal 25: Negative (–) Termina ...

  • Murphy Automatic Engine Controller A88 - page 13

    Fuel V alve Start Float Switch 100 1/2 W Ignition N.O. Battery Pos. Ground Pickup Oil Level Switch Crank Diagram 5: A88/A88-F Wiring for Honda Generator Green Y ellow Ground for Alarm Before Start IN4005 Oil Press. Shutdown Grey/White Brown/White Stop White/Y ellow White/Brown Black Blue Red Black/White White Red/White Ignition N.C. Green/White A88 ...

  • Murphy Automatic Engine Controller A88 - page 14

    100 1/2 W Diagram 6: A88/A88-F Wiring for Honda Generator White Black Blue Red 18 ga White/Brown Grey/White Red/White Red/White A88 White/Orange 23 25 7 26 1 16 11 4 12 15 21 or A88-F E IG BA T LO ST Combination Switch Brown/White Grey/White Red/White 17 T o Y ellow/Red (OIL) T o Y ellow/Grn (TEMP) Closed to Start Open to Stop Connect Black/Red Whi ...

Fabricant Murphy Catégorie Automobile Parts

Les documents que nous recevons du fabricant de l'appareilMurphy Automatic Engine Controller A88 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Murphy
- manuels d’utilisations Automatic Engine Controller A88
- fiches produit Murphy
- dépliants
- ou étiquettes-énergie Murphy Automatic Engine Controller A88
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Murphy Automatic Engine Controller A88.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Murphy Automatic Engine Controller A88, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Murphy Automatic Engine Controller A88. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Murphy Automatic Engine Controller A88.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Murphy Automatic Engine Controller A88, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Murphy Automatic Engine Controller A88 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Murphy Automatic Engine Controller A88.

Le manuel d’utilisation complet Murphy, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Murphy Automatic Engine Controller A88 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Murphy Automatic Engine Controller A88, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMurphy Automatic Engine Controller A88 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Murphy Automatic Engine Controller A88 - qui devraient nous aider dans les premières étapes lors de l'utilisation Murphy Automatic Engine Controller A88
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Murphy Automatic Engine Controller A88
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Murphy Automatic Engine Controller A88 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Murphy Automatic Engine Controller A88?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Murphy Automatic Engine Controller A88, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Murphy Automatic Engine Controller A88 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)