Manuale per l’uso Allegro Industries 9832

13 pagine 0.24 mb
Scarica

Vai alla pagina of 13

Summary
  • Allegro Industries 9832 - page 1

    USER'S MANUAL AMBIENT AIR BREATHING APPARATUS (AABA) PUMPS P/N 9806 P/N 9821 P/N 9832 P/N 9833 P/N 9846 P/N 9850 Read and understand all instructio ns before using this product. Open carton carefully and inspect pr oduct for damage caused by carrier. If any damage is found, report and submit claim to carrier. ALLEGRO ® INDUSTRIES P/N: UM006 ...

  • Allegro Industries 9832 - page 2

    TABLE OF CONTENTS PAGE NUMBER INTRODUCTION/D ESCRIPTION ...................................................................................................... ............... 1 WARNINGS AND LI MIT ATIONS ....................................................................................................... ............... 1 SAFETY PREC AUTIONS .... ...

  • Allegro Industries 9832 - page 3

    INTRODUCTION This manual provides instructions for the u se and maintenance of Allegro Ambient Air Breathing Apparatus (AABA) Pumps. You must read and understand this manual and be trained in the proper use of the equipment before using it in a contam inated atmosphere . There are many federal, state, and l ocal codes and regulat ions governi ng sa ...

  • Allegro Industries 9832 - page 4

    S A F E T Y P R E C A U T I O N S FOLLOW ALL WARNIN GS AND CAUT IONS ALL PUMPS: DO NOT place oil-less air pum p in an area that cannot GU ARANTEE clean Gra de D breathable air, per OSHA 29 CFR 1910.134 to the AABA inlet. See below for Grade D requirements. DO NOT attempt to service the air pump while it is running or while it is connected to electr ...

  • Allegro Industries 9832 - page 5

    U S E R ’ S I N S T R U C T I O N S 1) Ensure that the pump (or inlet extension filter) is in a clean uncontamin ated air environment. o If clean air CANNOT be guaranteed at the pump inlet at all times, use the Inlet extension hose kit (P/N: 9700-65). See instructions on the Inlet extension k it below. 2) Ensure canister on the disch arge filter ...

  • Allegro Industries 9832 - page 6

    T O L E R A N C E S A N D W A R N I N G S Allegro ambient air pum ps are precision pum ps that have only .0015-.003 cl earance between the top o f the rotor a nd cylinder bore, and .003 or less cleara nce be tween end of the rotor a nd the end plate. Any thrust on th e shaft such as mishandling or drop ping the pump on its end will tend to close th ...

  • Allegro Industries 9832 - page 7

    S P E C I F I C A T I O N S The table shows the maximum allowable number of tight-fitting respirators or loose-fitting hood s. MODEL NUMBER PART NO. MAX NO. RESP. MAX NO. HOODS POWER REQUIRED LBS HP PSI CFM A-300 9806 1 0 5.5A 115/2 30V 30 ¼ 0 – 15 0 – 5 A-750 9821 2 1 8.3A 115/2 30V 53 ¾ 0 – 15 0 – 10 A-1500TE 9832 3 2 16A 115/23 0V 97 1 ...

  • Allegro Industries 9832 - page 8

    M A I N T E N A N C E FILTERS: • Change inlet filter every 200 runn ing hours or if the pressure gauge shows a drop in pressur e. • Change discharge filter every 200 running hours or if the pressure gauge shows an increase in pressure. FLUSHING INSTRUCTIONS: 1. Perform this procedure in a well ventilated area. 2. Wear solvent resistant glo ves ...

  • Allegro Industries 9832 - page 9

    P A R T S & A C C E S S O R I E S All Models • 9700-02 Exhaust filter element (Each) • 9700-11 Pump flushing liqui d • 9700-15 Exhaust filter canister (Canister only) • 9700-65 Universal inlet hose kit (50 Feet) • 9700-68 ⅜ ” Coupler, locking Hansen • 9700-69 ⅜ ” Coupler, Hansen • 9700-71 ¼” Coupler, Schra der • 9700- ...

  • Allegro Industries 9832 - page 10

    T R O U B L E S H O O T I N G ELECTRIC MODELS: 1) If motor fails: • If motor is extrem ely cold. o Bring to room temperature before starting. • Ensure respirator and hose are connected when pump is running; failure to do so may cause lock-up. o Loosen all six pump end plate bolts sl ightly. R e-tighten a nd try t o run uni t. • Some motors ar ...

  • Allegro Industries 9832 - page 11

    4) If there is a drop in outlet pressure: • Check if exhaust filter housing and can ister is cross- t hreaded or not seated firmly onto housing gasket. o Remove canister, inspect t hreads and gasket and reinstall. • Check for dirty inlet filter element. o Replace if necessary. • Check if vanes are sticki ng or worn out. o Flush pump with appr ...

  • Allegro Industries 9832 - page 12

    WARRANTY Damage resulti ng from carri er handling abus e is not covere d by product war ranty. To protect your interest , inspect product im mediatel y. The foll owing warra nty inf ormation i s made in lieu of all other warranties expressed, implied or statutory, including but not li mited to, the implied warran ties of merchantability and fitness ...

  • Allegro Industries 9832 - page 13

    ambairpumman.doc Rev C. 07/03 11 ...

Fabbricante Allegro Industries Categoria Oxygen Equipment

I documenti che otteniamo dal fabbricante del dispositivoAllegro Industries 9832 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Allegro Industries
- manuali per l’uso 9832
- schede prodotto Allegro Industries
- opuscoli
- o etichette energetiche Allegro Industries 9832
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Allegro Industries 9832.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Allegro Industries 9832, manuali di manutenzione, brevi manuali o manuali utente Allegro Industries 9832. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Allegro Industries 9832.

Manuali per l’uso simili

Manuale completo del dispositivo Allegro Industries 9832, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Allegro Industries 9832 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Allegro Industries 9832.

Il manuale per l’uso completo Allegro Industries, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Allegro Industries 9832 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Allegro Industries 9832, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Allegro Industries 9832 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Allegro Industries 9832 - che ci dovrebbe aiutare nei primi passi durante l'uso Allegro Industries 9832
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Allegro Industries 9832
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Allegro Industries 9832 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Allegro Industries 9832?

Utilizza il modulo sottostante

Se non hai risolto il problema con Allegro Industries 9832 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Allegro Industries 9832 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)