Manuale per l’uso N-Tron 604MFX-ST

22 pagine 0.17 mb
Scarica

Vai alla pagina of 22

Summary
  • N-Tron 604MFX-ST - page 1

    12/15/05 1 600 Series Industrial Ethernet Switches Hardware Installation Guide ...

  • N-Tron 604MFX-ST - page 2

    12/15/05 2 Industrial Ethernet Switch In stallation Guide 604MFX-ST 604MFXE-ST-15 604MFXE-ST-40 604MFXE-ST-80 608MFX-ST 608MFXE-ST-15 608MFXE-ST-40 608MFXE-ST-80 ...

  • N-Tron 604MFX-ST - page 3

    12/15/05 3 Copyright, © N-TR ON Corp., 2002 820 S. University B lvd., Suite 4E Mobile, AL USA 3 6609 All rights reserved. Rep roduction, adaptation , or translation without p rior written permission from N-TRON Co rp. is prohibited, ex cept as allowed u nder copyright laws . Ethernet is a registered trademark of Xerox Corporatio n. All other pro d ...

  • N-Tron 604MFX-ST - page 4

    12/15/05 4 Safety Warnings ELECTRICAL SAFETY WARNING: Disconnect the power cable before removing the enclosure top. WARNING: Do not operate the unit with the top cover removed. WARNING: Do n ot work o n equipment o r cables du ring periods of lightning activity. WARNING: Do not perform any services on the unit unless qu alified to do so. WARNING: D ...

  • N-Tron 604MFX-ST - page 5

    12/15/05 5 600 Series Industrial Ethernet Switch The N-TRON 600 Series are product derivatives of the OSM/ESM family jointly manufactured by Siemens and N-TRON. The N-TRON 600 Series switches supports high speed layer 2 switching between ports, and is housed in a ruggedized steel enclosure, and can withstand industrial temperatures, as well as high ...

  • N-Tron 604MFX-ST - page 6

    12/15/05 6 PACKAGE CONTENTS Please make sure the Ethernet Switch package contains the following items: 1. 600 Series Ethernet Switch 2. This Installation Guide Contact your carrier if any items are damaged. INSTALLATION Read the following warning before beginning the installation: WARNING The FXE units contain a class 1 laser. Do not stare into the ...

  • N-Tron 604MFX-ST - page 7

    12/15/05 7 600 Series Hazardous Location Installation Requirements 1. WARNING! Do not disconnect while circuit is live, unless area is known to be non-hazardous. 2. WARNING! Install only in accordance with Local & National Codes of .Authorities Having Jurisdiction. 3. Class I, Div 2 installation requires that all devices connected to this produ ...

  • N-Tron 604MFX-ST - page 8

    12/15/05 8 APPLYING POWER 1. Unscrew the flange & remove the DC Voltage Input Plug from the Header. 2. Install the DC Power Cables into the Plug(s) (observing polarity per the legend on the top of the unit). L1+ and L2+ are the +24V connections. M1 and M2 are the minus (-) returns for the L1 and L2 respectively. F1 and F2 terminals are across t ...

  • N-Tron 604MFX-ST - page 9

    12/15/05 9 CONNECTING THE STANDARD RING Remove the dust cap from the f iber optic connectors and connect the fiber optic cables. Please refer to the Figure 1. Diagram. To begin the ring, the TX out-port #7 should be connected to the RX in-port #8 of the far end station. The RX in- port #7 should be connected to the TX out-port #8 on the far end sta ...

  • N-Tron 604MFX-ST - page 10

    12/15/05 10 For 10/100 Base-TX ports, plug a Category 5 (or better) twisted pair cable into one the RJ45 copper ports (1-6 ). Connect the o ther end to the far end st ation. Verify that the Port L ED’s are ON once the connection has been completed. For Switch to Switch o r Switch to Repeater connections, a crossov er cable may be required if the ...

  • N-Tron 604MFX-ST - page 11

    12/15/05 11 608MF X R I N G MA N A G E R 608 MFX Ne two rk Seg ment R edu nd an cy Figu re 2 608M FX 608M FX Sta n d b y M as t e r FIBER OP T IC P A IR FIBER OP T IC P A IR FIBER OP TIC PA IR #7 #8 #7 #8 # 7 #8 #7 #8 608M FX Stan d by Slave 608M FX 608M FX FIBER OP T IC P A IR FIBER OP TIC PA IR #7 #8 # 7 #8 608M FX 608MF X R I N G MA N A G E R FI ...

  • N-Tron 604MFX-ST - page 12

    12/15/05 12 DISPLAYS AND OPERATING CONTROLS LED’s Fault (red LED) Status Meaning ON The 604/608MFX has detected an error. The signaling contact opens at the same time. OFF No errors detected by the 604/608MFX. Stby - Standby (green LED, 608MFX Only) Status Meaning ON The 608MFX standby function is activated, indicating the 608MFX is in the standb ...

  • N-Tron 604MFX-ST - page 13

    12/15/05 13 Port LED’s The display Mode is indicated by the LED pair labeled “Display Mode”, and the state is given by th e legend on the front of the 600 Series Switch. To transition between these Display Modes, the Select/Set button must be pressed briefly (similar to left mouse click). The four states are: Port Status, 100Mbit/s, Full Dupl ...

  • N-Tron 604MFX-ST - page 14

    12/15/05 14 “Select/Set” Button The Select/Set” multi-functional button on the front panel of the 604/608MFX performs the following actions: • Pressing the button briefly (similar to left mouse click) transitions the display of the two display mode LED’s. The current display mode is indicated by the status of the display mode LED’s per ...

  • N-Tron 604MFX-ST - page 15

    12/15/05 15 Aging Time The 604/608MFX monitors the ag e of the addresses it h as learnt, an d addresses that exceed a certain age (aging time, default setting = 40 sec), are deleted again by the sw itch. If a p acket with a source address matching the address entry is received before the aging time elapses, the address entry is retained, and th e a ...

  • N-Tron 604MFX-ST - page 16

    12/15/05 16 Serial Interface The 604/608MFX provides an EIA-2 32 in terface accessed via a 9 pin male connector (labeled V24 on the unit). This is used to access the Command Line Interpreter (CLI). Functions in clude setting the IP address, and other parameters ( see Network Management Users guide). Th e pin-outs are shown below: DSR Pin 6 RTS Pi n ...

  • N-Tron 604MFX-ST - page 17

    12/15/05 17 Serial Cable Connect the serial COM port of your PC and the 600 Ser ies Switch u sing a normal n ull modem cable (or a straight through cable with a null modem adapter). You will require a cable with a 9 -pin or 25-pin sub-D female connector for th e PC end , and a 9-pin female su b-D connector for the 608MFX end. The fo llowing table s ...

  • N-Tron 604MFX-ST - page 18

    12/15/05 18 TROUBLESHOOTING 1. Make sure the Power LED (L1 and/or L2) is ON. 2. Make sure the Voltage is within specifications (18-32V@1A). 3. Make sure the fiber ports and TX ports are properly connected. 4. Verify that Port LED’s are ON for connected ports. 5. Verify the status of the fault (RM) LED. 6. Verify cabling (pin-outs & integrity) ...

  • N-Tron 604MFX-ST - page 19

    12/15/05 19 KEY SPECIFICATIONS Physical Height: 5.5" (13.65 cm) Width: 8.55" (21.70 cm) Depth: 2.75" (6.90 cm) Weight: 3.08 lbs (1.4 kg ) Electrical Input Voltage: 18-32 VDC (Redundant inputs) Input Current: 1.0A @ 24V Power Consumption: 24 Watts @24V Environmental Operating Temperature: 0°C to 60°C Storage Temperature: -40°C to 8 ...

  • N-Tron 604MFX-ST - page 20

    12/15/05 20 Key Specifications (Cont.) Emissions and Safety Approvals: FCC Part 15 Class A CE, UL, FM Class 1 Div 2 Groups A,B,C,D Note: Shielded cables must be used to meet emission standards. Ordering Information PN Description 604MFX-ST Industrial Ethernet Switch, ST Fiber Connectors, 608MFX-ST MM, 2km 604MFXE-ST-YY Industrial Ethernet Switch, S ...

  • N-Tron 604MFX-ST - page 21

    12/15/05 21 N-TRON Limited Warrant y N-TRON, Corp. warra nts to the end user that this hardwa re product will be free from defects in workmanship and materials, under normal use and service, for the applicable war ranty period from the data of purchase from N-TRON or its authorized reseller. If a product does not operate as warranted during the app ...

  • N-Tron 604MFX-ST - page 22

    12/15/05 22 AND NON-INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED. N-TRON NEIT HER ASSUMES NOR AUTHORIZ ES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIAB ILITY IN CONNECTION WITH THE SALE , INSTALLATION, MAINTENANCE OR US E OF ITS PRODUCTS. N-TRON SHALL NOT BE LIABLE UNDER T HIS WARRANTY IF ITS TE STING AND EXAMINATION DISCLOSE THAT THE ALL ...

Fabbricante N-Tron Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoN-Tron 604MFX-ST possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici N-Tron
- manuali per l’uso 604MFX-ST
- schede prodotto N-Tron
- opuscoli
- o etichette energetiche N-Tron 604MFX-ST
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso N-Tron 604MFX-ST.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione N-Tron 604MFX-ST, manuali di manutenzione, brevi manuali o manuali utente N-Tron 604MFX-ST. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto N-Tron 604MFX-ST.

Manuali per l’uso simili

Manuale completo del dispositivo N-Tron 604MFX-ST, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare N-Tron 604MFX-ST dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti N-Tron 604MFX-ST.

Il manuale per l’uso completo N-Tron, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale N-Tron 604MFX-ST - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice N-Tron 604MFX-ST, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per N-Tron 604MFX-ST che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo N-Tron 604MFX-ST - che ci dovrebbe aiutare nei primi passi durante l'uso N-Tron 604MFX-ST
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del N-Tron 604MFX-ST
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio N-Tron 604MFX-ST in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su N-Tron 604MFX-ST?

Utilizza il modulo sottostante

Se non hai risolto il problema con N-Tron 604MFX-ST con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con N-Tron 604MFX-ST è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)