Manuale per l’uso Desa 90

32 pagine 0.52 mb
Scarica

Vai alla pagina of 32

Summary
  • Desa 90 - page 1

    Heater Sizes: 30,000 70,000 90,000 150,000 BTU/Hr IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. 150 SIDE PV 004 100 SIDE PV 002 PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL RD D Y H a TR ee e ® G 031 ...

  • Desa 90 - page 2

    2 099606 Safety Information ......................................................................... 3 Product Identification .................................................................... 4 Unpacking ...................................................................................... 5 Assembly ........................................... ...

  • Desa 90 - page 3

    3 099606 SAFETY INFORMA TION ! W ARNINGS IMPORTANT: Read this owner ’ s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fi re, explosion, electrical shock, and carbon monoxide poisoning. ! DANGER Carbon monoxide poisoning may lea ...

  • Desa 90 - page 4

    4 099606 150,000 BTU/HR EURO PFA/PV 045 Fuel Cap Lower Shell Power Cord Upper Shell Figure 3 - 150,000 BTU/Hr Model 35/50/70,000 BTU/HR DOMESTIC PFA/PV 042 Handle Fuel Cap Lower Shell Side Cover Fuel Tank Figure 1 - 30/70,000 BTU/Hr Models Side Cover Fuel Tank Lower Shell Fuel Cap Fan Guard Power Cord Upper Shell PRODUCT IDENTIFICA TION Upper Shell ...

  • Desa 90 - page 5

    5 099606 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y (For 90,000 and 150,000 BTU/Hr Models Only) These models are furnished with wheels and handles. Wheels, handles, and ...

  • Desa 90 - page 6

    6 099606 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fi ne mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the combustion cham ...

  • Desa 90 - page 7

    7 099606 VENTILA TION OPERA TION Continued Figure 6 - Flame-Out Control Reset Button, 30/70,000 BTU/Hr Figure 7 - Flame-Out Control Reset Button, 90,000 BTU/Hr ! W ARNING Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh ...

  • Desa 90 - page 8

    8 099606 OPERA TION Continued Figure 8 - Flame-Out Control Reset Button, 150,000 BTU/Hr Continued PREVENT A TIVE MAINTENANCE SCHEDULE Item How Often How To Fuel tank Flush every 150-200 hours See Storage above. of operation or as needed. Air output and Replace every 500 hours of See Air Output, Air Intake , lint fi lters operation or once a year. ...

  • Desa 90 - page 9

    9 099606 Continued Item How Often How To Spark plug Clean and regap every 600 See Spark Plug , pages 12 and 13. hours operation or replace as needed. Fan blades Clean every season or as needed. See Fan , page 19. Motor Not required/permanently lubricated TROUBLE- SHOOTING OBSERVED FAULT POSSIBLE CAUSE REMEDY Wrong pump pressure Dirty air output, ai ...

  • Desa 90 - page 10

    10 099606 150 SHELL REMOVAL EA/EB Euro PV 020 Upper Shell Fan Guard Figure 12 - Fuel Filter Removal, 30/70,000 BTU/Hr Models Figure 11 - Upper Shell Removal, 150,000 BTU/Hr Model Figure 9 - Upper Shell Removal, 30/70,000 BTU/Hr Models Figure 10 - Upper Shell Removal, 90,000 BTU/Hr Model Upper Shell Fan Guard Fuel Filter Side Cover Fuel Line Fuel Fi ...

  • Desa 90 - page 11

    11 099606 100 FUEL FILTER REMOVAL PFA/P 041 150 FUEL FILTER REMOVAL PFA/P 043 Fuel Filter (90,000 BTU/Hr Model) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel fi lter neck. 4. Carefully pry bushing, lower fuel line, and fuel fi lter out of fuel tank. 5. Wash fuel fi lter with clean ...

  • Desa 90 - page 12

    12 099606 Spark Plug (30,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from nozzle assembly. 4. Remove spark plug wire from spark plug. 5. Remove two screws using 5/16" nut-driver and remove burner strap. 6. Place hex-body of spark plug into vise and tighten. 7. Remove spa ...

  • Desa 90 - page 13

    13 099606 Spark Plug (70/90/150,000 BTU/Hr Models) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Clean and regap spark plug electrodes to .055" (1.4 mm) gap. 6. Install spark plug in burner head. 7. Attach ...

  • Desa 90 - page 14

    14 099606 Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover. 4. Replace air output and lint fi lters. 5. Wash or replace air intake fi lter (see Preventative Maintenance Schedule, page 8). 6. Replace fi lter end cover. 7. Re ...

  • Desa 90 - page 15

    15 099606 Nozzle (30,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from nozzle assem- bly. 4. Turn nozzle assembly 1/4 turn to left and pull toward motor to remove. 5. Place plastic hex-body into vise and lightly tighten. 6. Carefully remove nozzle from the nozzle adapter using ...

  • Desa 90 - page 16

    16 099606 Nozzle (70/90,000 BTU/Hr Models) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using 5/16" nut-driver and remove burner head ...

  • Desa 90 - page 17

    17 099606 Nozzle (150,000 BTU/Hr Model) 1. Remove upper shell (see page 10). 2. Remove fan (see page 19). 3. Remove spark plug wire from spark plug. 4. Remove spark plug from burner head using 13/16" open-end wrench. 5. Loosen fl are nut using 3/4" open-end wrench. Push fuel tube down. 6. Remove air line hose from burner head. 7. Remove ...

  • Desa 90 - page 18

    18 099606 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover and air fi lters. 4. Remove pump plate screws using 5/16" nut- driver. 5. Remove pump plate. 6. Remove rotor, insert, and blades. 7. Check for debris in pump. ...

  • Desa 90 - page 19

    19 099606 Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 10). 2. Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft. 3. Slip fan off motor shaft. 4. Clean fan using a soft cloth moistened wi ...

  • Desa 90 - page 20

    20 099606 ILLUSTRA TED P ARTS BREAKDOWN 30,000 BTU/Hr 18-1 18-2 18-3 18-4 18-5 18-6 18-7 18-8 18-9 18-10 18-11 18-12 18-13 18-14 18-15 18-16 18-17 18-18 Motor and Pump Assembly 1 2 3 4 5 6 7 8 9 11 12 13 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 35 36 37 38 39 14 10 11-1 11-2 11-3 11-4 11-5 33 34 40 41 42 ...

  • Desa 90 - page 21

    21 099606 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 30,000 BTU/Hr KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-36 Upper Shell 1 3 M15823 ...

  • Desa 90 - page 22

    22 099606 1 2 4 3 5 6 7 8 10 11 12 12 14 15 16 (2) 17 20 18 19 21 22 24 25 26 27 28 29 30 31 32 34 38 37 41 13 9 33 35 36 42 43 39 40 23 44 ILLUSTRA TED P ARTS BREAKDOWN 70,000 BTU/Hr 18-1 18-2 18-3 18-4 18-5 18-7 18-8 18-9 18-10 18-11 18-12 18-14 18-15 18-16 18-18 18-17 18-6 PFA/P 007 MOTOR & PUMP 70 EAI/EBI 18-13 Motor and Pump Assembly Burne ...

  • Desa 90 - page 23

    23 099606 P ARTS LIST 70,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. **Not available as an assembly, order parts separately. KEY PART PART NO. NUMBER DESCRIPTION QTY. ...

  • Desa 90 - page 24

    24 099606 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 (2) 17 18 19 20 25 26 29 30 31 32 33 34 35 36 37 38 39 40 41 6 42 43 21 22 23 24 45 44 27 28 46 PFA/P 010 MOTOR & PUMP 100 EAI/EBI ILLUSTRA TED P ARTS BREAKDOWN 90,000 BTU/Hr 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13-8 13-9 13-10 13-11 13-12 13-13 13-15 13-16 13-17 13-18 13-14 Motor and Pump Assembly B ...

  • Desa 90 - page 25

    25 099606 P ARTS LIST 90,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. **Not available as an assembly, order parts separately. KEY PART PART NO. NUMBER DESCRIPTION QTY. ...

  • Desa 90 - page 26

    26 099606 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 9 23 24 25 26 27 28 29 30 31 13 32 9 32 33 34 9 35 36 37 40 41 42 43 9 45 46 47 9 48 44 49 50 51 32 52 6 39 38 21 53 9 54 BURNER HEAD 150 EAI/EBI PFA/P 028 ILLUSTRA TED P ARTS BREAKDOWN 150,000 BTU/Hr 22-1 22-2 22-3 22-4 22-5 22-6 22-7 22-8 22-9 22-10 22-11 22-12 22-13 22-14 22-15 22-16 ...

  • Desa 90 - page 27

    27 099606 KEY PART PART NO. NUMBER DESCRIPTION QTY. 22-15 M12461-34 Screw, #10-32 x 1 1/2" 6 22-16 M11637 Lint Filter 1 22-17 M50820-02 Barb Fitting 1 22-18 M8643-3 Blade 4 23 M12651-1 Capacitor Clamp 1 24 M12650-3 Capacitor 1 25 M12828 Shell Support Bracket 1 26 M30865-04 Open/Closed Bushing 1 27 M16645 Motor Support Bracket 1 28 M51357-01 Ca ...

  • Desa 90 - page 28

    28 099606 ASSEMBLY, EURO PFA/PV 018A 1 2 3 4 5 6 7 KEY PART PART 90,000 150,000 NO. NUMBER DESCRIPTION QTY. QTY. 1 HA2203 Handles 2 — HA2205 Handles — 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 8 3 M12342-3 Wheel Support Frame 1 — M12831-3 Wheel Support Frame — 1 4 NTC-3C Hex Nut, #10-24 8 8 5 097896-01 Wheel 2 2 6 M28526 Cap Nut 2 2 7 M51 ...

  • Desa 90 - page 29

    29 099606 WIRING DIAGRAMS Ignitor White Brown Blue Green/Yellow Photocell Spark Plug Flame- Out Control B Reset Button R Red Blue White Blue White Red Red Orange Terminal Board Motor Green/ Yellow Red Motor Start Relay Black S or 2 M or 3 L or 1 230V/50Hz Ignitor White Brown Blue Green/Yellow Photocell Spark Plug Flame- Out Control B Reset Button R ...

  • Desa 90 - page 30

    30 099606 ACCESSORIES Purchase accessories from your local dealer. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. For 30/70,000 BTU/Hr models. AIR GAUGE KIT - HA1180 For all models. Special tool to check pump pressure. STANDARD WHEELS AND HANDLE KIT - HA1206 Makes heater e ...

  • Desa 90 - page 31

    31 099606 NOTES ...

  • Desa 90 - page 32

    32 099606 W ARRANTY AND REP AIR SERVICE POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. Any transportation charges, costs of installation, duty, taxes or any other charges whatsoever must be borne by the user. DESA International&apo ...

Fabbricante Desa Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoDesa 90 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Desa
- manuali per l’uso 90
- schede prodotto Desa
- opuscoli
- o etichette energetiche Desa 90
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Desa 90.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Desa 90, manuali di manutenzione, brevi manuali o manuali utente Desa 90. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Desa 90.

Manuali per l’uso simili

Manuale completo del dispositivo Desa 90, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Desa 90 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Desa 90.

Il manuale per l’uso completo Desa, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Desa 90 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Desa 90, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Desa 90 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Desa 90 - che ci dovrebbe aiutare nei primi passi durante l'uso Desa 90
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Desa 90
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Desa 90 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Desa 90?

Utilizza il modulo sottostante

Se non hai risolto il problema con Desa 90 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Desa 90 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)