  • Weil-McLain LGB - page 1

    Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance . • Do not touch any electrical switch ; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’ s phone . Follow the gas sup ...

  • Weil-McLain LGB - page 2

    2 Part Number 550-110-592/1000 Please read this page first How to use this manual . . . The User ’ s Infor mation Manual pro vides information to the boiler o w ner/user for r outine operation and maintenance and emergency shutdown. Detailed information on boiler installation, operation, start-up, service and parts is included in the Boiler Manua ...

  • Weil-McLain LGB - page 3

    3 Part Number 550-110-592/1000 F ailure t o adher e to the guidelines on this pag e can result in sev ere personal injury , death or substantial property damage. STOP!! — Read before proceeding Products to avoid Spray cans containing chloro/fluorocar- bons Permanent wave solutions Chlorinated waxes/cleaners Chlorine-based swimming pool chemicals ...

  • Weil-McLain LGB - page 4

    4 Part Number 550-110-592/1000 5921 0 Boiler components 5921 1 1 Gas valve 2 Pilot burner 3 Main burner 4 Gas manifold/orifices 5 Control module 6 Inducer (CGi and CGs only) 7 V ent damper (CGa only) 8 W ater temperature limit switch 9 T ransformer 10 Spill switc h (CGa only) 11 Air pressure switc h (CGi and CGs only) 12 Rollout thermal fuse elemen ...

  • Weil-McLain LGB - page 5

    5 Part Number 550-110-592/1000 ▲ ▲ 59215 (PFG-5 only) (PFG-5 only) ▲ ▲ Not shown ▲ 1 Gas valve 2 Pilot burner 3 Main burner 4 Gas manifold/orifices 5 Control module 7 V ent damper 9 T ransformer 10 Spill switc h 12 Rollout thermal fuse element 13 Low water cutoff (steam boilers) 14 Limit control(s) 15 Draft hood 16 Circulator 18 Gauge (pr ...

  • Weil-McLain LGB - page 6

    6 Part Number 550-110-592/1000 Maintain boiler using schedule below T ankless water heater (EG and EGH only) If boiler is used to supply d omestic hot water , limit co ntrol should be set to suppl y adequate hot water . W eil-M cLain tankless heaters are rated at 200 ° F boile r water t emperature. T o ge t rated output, set low limit at 200 ° F ...

  • Weil-McLain LGB - page 7

    7 Part Number 550-110-592/1000 User maintenance procedures Do not attempt to place boiler in operation if spill switch cuts of f gas flow . Immediately call a serv ice technician. Failure to do so can cause severe personal injury , death or substantial pr oper t y damage. Rollout thermal fuse element CGa, CGi, CGs, EG, EGH, PEG & PFG-5 only Cu ...

  • Weil-McLain LGB - page 8

    8 Part Number 550-110-592/1000 ❏ Check daily . . . . . . . . . . . . . . . . . Air openings 1 . V er ify that combustion and v entilation air openings to the boiler room and/or building are open and unobstructed. 2. CGs boilers — V erify that b oiler vent disc harge and air intake are clean and free of obstructions. Remove any debris on the air ...

  • Weil-McLain LGB - page 9

    9 Part Number 550-110-592/1000 Figure 4 Automatic air vent Automatic air vents (if used) 1 . See Figure 4 . 2 . Remove the cap from any automatic air vent in the system and check operation by depressing valve B slightly with the tip of a screwdriv er . 3. If the air vent valve appears to be working freely and not leaking , replace cap A , twisting ...

  • Weil-McLain LGB - page 10

    10 Part Number 550-110-592/1000 Probe type— See Figure 8 1 . Clean probe type low water cutoff for proper operation. a. T urn off power to boile r and wait 5 minutes. b . Drain water to bottom of gauge glass. c. T urn o n pow er . d. Set thermostat to call for heat. Red neon lamp on lower water cutoff should light. e. W ait 5 minutes. Boile r sho ...

  • Weil-McLain LGB - page 11

    11 Part Number 550-110-592/1000 Operate boiler relief valve ❏ Service every 6 months . . . . . . . . . To av oid water damage or scalding due to valve operation, a metal discharge line must be connected to relief valve outlet and run to a safe place of disposal. This discharge line must be installed by a qualified heating installer or service tec ...

  • Weil-McLain LGB - page 12

    12 Part Number 550-110-592/1000 Follow boiler shutdown procedure ❏ End-of-season shutdown . . . . . . . . 1. Follo w “ TO TURN OFF GA S T O APPLIANCE ” on the Lighting/Operating instr uctions on the inside of the jacket panel. Y ou will also find these instructions on pages 13 through 22 of this manual. U se the Lighting/Operating instr uctio ...

  • Weil-McLain LGB - page 13

    13 Part Number 550-110-592/1000 Lighting instructions FOR Y OUR S AFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the g ...

  • Weil-McLain LGB - page 14

    14 Part Number 550-110-592/1000 • Gas valve — Robertshaw 7200 FOR Y OUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. F ...

  • Weil-McLain LGB - page 15

    15 Part Number 550-110-592/1000 FOR Y OUR S AFETY READ BEFORE LIGHTING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the gas supplier ’ s i ...

  • Weil-McLain LGB - page 16

    16 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain LGB - page 17

    17 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain LGB - page 18

    18 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain LGB - page 19

    19 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE OPERA TING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighbor ’ s phone. Follo w the gas supplier ’ s ...

  • Weil-McLain LGB - page 20

    20 Part Number 550-110-592/1000 FOR Y OUR SAFETY READ BEFORE LIGHTING OPERA TING INS TRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediate ly call your gas supplier fr om a neighb or ’ s phone. Follo w the gas supplier ’ s i ...

  • Weil-McLain LGB - page 21

    21 Part Number 550-110-592/1000 FOR YOUR SAFETY READ BEFORE OPERA TING OPERA TING INSTRUCTIONS TO TURN OFF GAS TO THE APPLIANCE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instru ...

  • Weil-McLain LGB - page 22

    22 Part Number 550-110-592/1000 ANNUAL SHUTDOWN PROCEDURE • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach y our gas supplier , call the fire dep ...

  • Weil-McLain LGB - page 23

    23 Part Number 550-110-592/1000 Common problems and solutions Symptom Common Causes Possible Corrections Rapid cycling — boiler turns on and off frequently Thermostat installed where drafts or heat affect reading Locate thermostat on inner wall away from heat sources or cool drafts. Heat anticipator in thermostat adjusted incorrectly Adjust therm ...

  • Weil-McLain LGB - page 24

    24 Part No. 550-110-592/1000 W eil-McLain Limited W arranty for Residential & Commercial Cast Iron Boilers W eil-McLain 500 Blaine Street Michigan City , IN 46360-2388 http://www .weil-mclain.com RESIDENTIAL W A TER W ARRANTY—Limited Lifetime RESIDENTIAL STEAM W ARRANTY—Limited 10 Y ear COMMERCIAL W ARRANTY—Limited 10-Y ear NOTE: The resi ...

Fabbricante Weil-McLain Categoria Boiler

I documenti che otteniamo dal fabbricante del dispositivoWeil-McLain LGB possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Weil-McLain
- manuali per l’uso LGB
- schede prodotto Weil-McLain
- opuscoli
- o etichette energetiche Weil-McLain LGB
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Weil-McLain LGB.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Weil-McLain LGB, manuali di manutenzione, brevi manuali o manuali utente Weil-McLain LGB. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Weil-McLain LGB.

Manuali per l’uso simili

Manuale completo del dispositivo Weil-McLain LGB, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Weil-McLain LGB dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Weil-McLain LGB.

Il manuale per l’uso completo Weil-McLain, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Weil-McLain LGB - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Weil-McLain LGB, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Weil-McLain LGB che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Weil-McLain LGB - che ci dovrebbe aiutare nei primi passi durante l'uso Weil-McLain LGB
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Weil-McLain LGB
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Weil-McLain LGB in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Weil-McLain LGB?

Utilizza il modulo sottostante

Se non hai risolto il problema con Weil-McLain LGB con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Weil-McLain LGB è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)