  • Quadra-Fire QVI-25FB-S - page 1

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 1 Model: QVI-25FB-S • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch. Do not use any phone in your building. - Imm ...

  • Quadra-Fire QVI-25FB-S - page 2

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Dealership purchased from: __________ ...

  • Quadra-Fire QVI-25FB-S - page 3

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 3 T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Speci fi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. High Altitude Installations . . . . . . . . . . . . . . . . . . ...

  • Quadra-Fire QVI-25FB-S - page 4

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 4 Note : T o assure top performance, safety and ef fi ciency , inserts must be installed with an approved fl ue liner as per CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and these instructions. Not e: This installation must c onform wi th local c odes. In the absenc e of local c odes y ...

  • Quadra-Fire QVI-25FB-S - page 5

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 5 Quadra-Fire gas inserts are designed for recessed installa- tions into solid fuel masonry or factory built non-combustible fi replaces that have been installed in accordance with the National, Provincial, State and local building codes. Prior to installing the gas insert: • Have the chim ...

  • Quadra-Fire QVI-25FB-S - page 6

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 6 3 3 F ireplace Size Requirements A. Minimum Fireplace Opening Minimum fi replace opening requirements are shown in Figure 3.1. • The fi rebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built fi rebox in order to gain minimum gas ...

  • Quadra-Fire QVI-25FB-S - page 7

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 7 B. Clearances Figure 3.2 Clearances to Mantels or other Combustibles above Appliance Fire Risk. • Locate and install appliance to all clearance speci fi cations in manual. Fire Risk. Odor Risk. • Clearance to combustible material under the insert is 1/4 inch (0.6 cm). • Use leveling ...

  • Quadra-Fire QVI-25FB-S - page 8

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 8 Fire Risk. Asphyxiation Risk. • T erminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. A. V ent T ermination Minimum Clearances Figure 4.1 speci fi es minimum vent heights for various pitched roofs. Roof Pitch H (Min.) Ft. Flat ...

  • Quadra-Fire QVI-25FB-S - page 9

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 9 CAUTION ALL vent speci fi cations MUST be followed. • This product is tested and listed to these speci fi cations. • Appliance performance will suffer if speci fi cations are not followed. Figure 5.1 C. Measuring Standards V ertical measurements listed in the vent diagram (Figure 5.1 ...

  • Quadra-Fire QVI-25FB-S - page 10

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 10 6 6 Installation Preparation Fire Risk. A hearth or hearth extension (if present) must comply with either of the following: • The solid fuel burning fi replace manufacturer’s speci fi cation. • Local building codes required by authority having jurisdiction. • NFPA 211 Prepare the ...

  • Quadra-Fire QVI-25FB-S - page 11

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 1 1 A. V enting Components 7 7 Installing V ent P ipe and Appliance The vertical vent termination system installed on this model includes: • One 3-foot section stainless steel fl exible pipe (included with insert). • One length of 3-inch fl exible vent pipe for combustion air (included ...

  • Quadra-Fire QVI-25FB-S - page 12

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 12 Figure 7.1 ST AINLESS STEEL ADAPTER FOR EXHAUST (MUST BE INST ALLED) INLET AIR VENT PIPE 3 INCH COLLAR OPTIONAL LINK-ZC-ADPB (For Flashing Class-A Pipe) TERMINA TION CAP (SQUARE FLASHING REMOVED) EXHAUST VENT PIPE SUPPLIED WITH TERMINA TION KIT INLET AIR VENT COLLAR (LINK-DV30 SHOWN) AL TE ...

  • Quadra-Fire QVI-25FB-S - page 13

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 13 Figure 7.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • T rim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 7.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top. C. Placing, Securing and Leveling the Appliance • ...

  • Quadra-Fire QVI-25FB-S - page 14

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 14 D. Installing Adaptor and T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) . T o install adaptor see Figure 7.3. Roof Pitch H (Min.) Ft. Flat to 6/12.................... 1.0* Over 6/12 to 7/12 ........1.25* Over 7/12 t ...

  • Quadra-Fire QVI-25FB-S - page 15

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 15 • Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes. • Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve. • Check all fi ttings and connections of appliance w ...

  • Quadra-Fire QVI-25FB-S - page 16

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 16 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.L. Listed gas appliances are tested and approved without requiring changes for elevatio ...

  • Quadra-Fire QVI-25FB-S - page 17

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 17 A. Wiring the Appliance 9 9 Elect rical Infor mation Note : This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code, CSA C221.1. ON/OFF S ...

  • Quadra-Fire QVI-25FB-S - page 18

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 18 B. Junction Box Installation Figure 9.2 Junction box installation FEED PLUG THROUGH HOLE INSERT RELIEF AROUND CORD IN THIS END FROM OUTSIDE OF UNIT JUNCTION BOX SIDE WALL Optional Accessories Connecting the electrical junction box is required if using a blower or remote. • Plug the cord ...

  • Quadra-Fire QVI-25FB-S - page 19

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 19 Figure 9.4 Fan Wiring Diagram JUNCTION BOX VARIABLE SPEED CONTROL TEMPERATURE SENSOR SWITCH WHT GRN BLK BLK 110-120 VAC BLOWER BLOWER RECEPTACLE BLK BLK BLK BLK WHT GROUND WHT BLK BLK BLK REMOTE RECEPTACLE INSERT STUD THROUGH HOLE AND SECURE WITH WING NUT WING NUT TEMP SWITCH BRACKET FAN T ...

  • Quadra-Fire QVI-25FB-S - page 20

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 20 A. Mantel Projections Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround. 1 0 10 Fin ishing Figure 10 .1 Clearances to Mantels or other Comb ...

  • Quadra-Fire QVI-25FB-S - page 21

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 21 Figure 1 1.1 Placement of Embers BURNER P AN EMBER PLACEMENT 1 1 11 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath i ...

  • Quadra-Fire QVI-25FB-S - page 22

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 22 E. Positioning the Logs Log Set Assembly: LOGS-2031 2031-700 4 5 6 1 3 2 FIREBOX LEDGE LOG PLACEMENT INSTRUCTIONS Log Placement CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG #1 FIREBOX LEDGE FIREBOX FIREBOX LEDGE LOG #1 (SRV2032-701): Place log #1 on the fi ...

  • Quadra-Fire QVI-25FB-S - page 23

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 23 LOG #3 (SRV2032-703): Position log #3 by locating its slot over the tab on right front of the burner such that left end of log contacts log tab near the center of the burner . LOG #2 (SRV2032-702): Position log #2 by locating its slot over the tabs on left front of the burner . 2 2 3 3 LOG ...

  • Quadra-Fire QVI-25FB-S - page 24

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 24 Figure 1 1.2 Glass Assembly F . Glass Assembly Removing Glass Assembly There are two glass latches on the left side of glass as- sembly and two glass latches on the right side. • T o release glass assembly , pull latch forward and allow to retract away from glass assembly . • Remove gl ...

  • Quadra-Fire QVI-25FB-S - page 25

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 25 Fire Risk. Explosion Risk. Gas may build up while lighting pilot. • Remove glass assembly before lighting pilot. • Replace glass assembly after lighting pilot. A. Before Lighting Appliance This appliance has a Standing Pilot Ignition. Before operating this appliance have a qualified te ...

  • Quadra-Fire QVI-25FB-S - page 26

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 26 B. Lighting Appliance Standing Pilot Ignition 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. Do not force. 5. Close cont ...

  • Quadra-Fire QVI-25FB-S - page 27

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 27 C. Check Pilot Flame Appearance Pilot fl ame must contact the thermocouple and thermopile for reliable appliance operation. • Pilot fl ame should be as shown in Figure 12.1. D. After Appliance is Lit Initial Break-in Procedure When you light the appliance, you may notice that it pro- d ...

  • Quadra-Fire QVI-25FB-S - page 28

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 28 E. Frequently Asked Questions Fire Risk. High T emperatures. Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air . • Do NOT place combustible items on top of or in front of appliance. • Keep furniture, draperies away from appliance. Smok ...

  • Quadra-Fire QVI-25FB-S - page 29

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 29 A. Standing Pilot Ignition System 1 3 13 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service person in the diagnosi ...

  • Quadra-Fire QVI-25FB-S - page 30

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 30 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals. The millivolt meter should read greater than 125 ...

  • Quadra-Fire QVI-25FB-S - page 31

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 31 1 4 14 Maintaining and Ser vicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each heating season. Annual inspection by qua ...

  • Quadra-Fire QVI-25FB-S - page 32

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 32 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary . 3. V erify no obstructions to air fl ow through the ...

  • Quadra-Fire QVI-25FB-S - page 33

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 33 Figure 15.1 Appliance Dimensions A 14-7/16 in. 377 mm C E 5-9/16 in. 1-1/16 in. G GAS INLET (GAS BALL V AL VE NOT SHOWN) H F D 3-5/8 in. REF 92 mm 3-7/16 in. 87 mm 1-1/16 in. 27 mm T wo 2-13/16 in. 71 mm B 4-3/8 in. 111 mm 1-9/16 in. 40 mm 1 5 15 Reference Materials A. Appliance Dimension ...

  • Quadra-Fire QVI-25FB-S - page 34

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 34 B. V ent Kits Components Direct V ent Flex Liner Kits (see Figure 15.2) LINK-DV -30B or (LINK-DV -30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter . LINK-DV4-30B or (LINK-DV4-30): Masonry 3 inch fl ex liner kit. ...

  • Quadra-Fire QVI-25FB-S - page 35

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 35 Service Parts Diagram QVI-25FB-S R Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ C. Service Parts List Part number list on following page. Log Set Assembly 4 2 1 3 5 6 7 8 9 10 11 12 13 14 15 16 ...

  • Quadra-Fire QVI-25FB-S - page 36

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 36 QVI-25FB-S Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION SE ...

  • Quadra-Fire QVI-25FB-S - page 37

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 37 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION SERIAL # P ART NUMBER 1 Pil ...

  • Quadra-Fire QVI-25FB-S - page 38

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 38 D. Limited Lifetime W arranty LIMITED LIFETIME W ARRANTY The Hearth & Home T echnologies limited Lifetime W arranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them. These items i ...

  • Quadra-Fire QVI-25FB-S - page 39

    Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 39 Quadra-Fire, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .quadra fi re.com E. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your nearest Quadra-Fire dealer , please vis ...

Fabbricante Quadra-Fire Categoria Indoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoQuadra-Fire QVI-25FB-S possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Quadra-Fire
- manuali per l’uso QVI-25FB-S
- schede prodotto Quadra-Fire
- opuscoli
- o etichette energetiche Quadra-Fire QVI-25FB-S
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Quadra-Fire QVI-25FB-S.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Quadra-Fire QVI-25FB-S, manuali di manutenzione, brevi manuali o manuali utente Quadra-Fire QVI-25FB-S. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Quadra-Fire QVI-25FB-S.

Manuali per l’uso simili

Manuale completo del dispositivo Quadra-Fire QVI-25FB-S, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Quadra-Fire QVI-25FB-S dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Quadra-Fire QVI-25FB-S.

Il manuale per l’uso completo Quadra-Fire, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Quadra-Fire QVI-25FB-S - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Quadra-Fire QVI-25FB-S, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Quadra-Fire QVI-25FB-S che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Quadra-Fire QVI-25FB-S - che ci dovrebbe aiutare nei primi passi durante l'uso Quadra-Fire QVI-25FB-S
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Quadra-Fire QVI-25FB-S
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Quadra-Fire QVI-25FB-S in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Quadra-Fire QVI-25FB-S?

Utilizza il modulo sottostante

Se non hai risolto il problema con Quadra-Fire QVI-25FB-S con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Quadra-Fire QVI-25FB-S è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)