Manuale per l’uso Porter-Cable H450CS, CH350CS, H650CS

20 pagine 1.33 mb
Scarica

Vai alla pagina of 20

Summary
  • Porter-Cable H450CS, CH350CS, H650CS - page 1

    Part No. D21269-007-0 Generators Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference. Model No. T ype Serial No. ESP AÑOL: PÁGINA 21 FRANÇAISE: P AGE 41 IMPORT ANT ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 2

    2 — ENG This product is not equipped with a spark arresting muf fler . If the pr oduct will be used around flammable materials, or on land covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then an approved spark arrester must be installed and is legally required in the state of California. It is a vi ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 3

    3 — ENG WARRANTY Porter-Cable Corporation 4825 Highway 45 North P .O. Box 2468 Jackson, TN 38302-2468 1-888-559-8550 PORTER-CABLE CORPORA TION warrants to the original pur chaser that each new electric generator and service part is free from defects in material and workmanship, and agrees to repair or replace under this warranty any defec- tive p ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 4

    4 — ENG Attempting to connect generator directly to the electrical system of any building structure. Back feeding electricity through a building’ s electrical system to the outside utility feed lines could en- danger repair persons attempting to restore service. Attempting to connect to the incoming utility service could result in electrocu- ti ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 5

    5 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. Use of worn, damaged, undersized or ungrounded extension cords. Placing generator on or against highly conductive surface, such as a steel walkway or metal roof. Improper connection of items to generator . Operation of unit when damaged, or with guards or panels ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 6

    6 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. RISK OF FIRE T ur n engine of f and allow it to cool before adding fuel to the tank. Equip area of operation with a fire extin- guisher certified to handle gasoline or fuel fires. Add fuel to tank in well ventilated area. Make sure there are no sources of igniti ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 7

    7 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. RISK OF BREA THING - INHALA TION HAZARD Operate generator in clean, dry , well ventilated area. Never operate unit in enclosed areas such as garages, basements, storage, sheds, or in any location occupied by humans or ani- mals. Keep children, pets and oth- ers ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 8

    8 — ENG READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. • Review and understand all of t he operating instructions and warnings in this manual. • Become familiar with the operation and controls of the generator . Know how to shut it off quickly . • Equip area of operation with a fire extinguisher certified to h ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 9

    9 — ENG RISK FROM LIFTING HAZARD HOW TO PREVENT IT WHA T COULD HAPPEN The generator is too heavy to be lifted by one person. Obtain assistance from others before you try to move it. Serious injury can result from attempt- ing to lift too heavy an object. Lifting a very heavy object. READ AND UNDERST AND ALL W ARNINGS BEFORE A TTEMPTING TO OPERA T ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 10

    10 — ENG Extension Cord Wire Gauge Chart Amperage *Up to 20 amp draw Up to 30 amp draw Cord Length 0 to 100 ft. 0 to 100 ft. Wire Gauge Size 12 ga. 10 ga. *NOTE: When amperage exceeds 20 amps; a 12 gauge extension cord should not be used for long distances. Extension Cords When using an appliance or tool at a considerable distance from the genera ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 11

    11 — ENG OPERA TION KNOW YOUR GENERA TOR Read this General Manual and Safety Rules before operation of your Generator . Compare the illustration in your parts manual with your generator to familiarize yourself with the location and use of various controls. Save all manuals for future references. IMPORT ANT : Exceeding the rated capacity of your g ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 12

    12 — ENG 2. Check fuel level and fill as required. Make sure generator is turned off and has been allowed time to cool down. Use clean, fresh, regular unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline. Never fill fuel tank completely . Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel e ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 13

    13 — ENG TO ST AR T THE ENGINE Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas. 1. Open the fuel shut-off valve on tank and engine. 2. Move the choke control located on the engine to "CHOKE" position. NOTE: No choke is required on warm engines. Make sure ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 14

    14 — ENG MAINTENANCE Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter , mor e often if operated in extreme dusty or dirty conditions. Note 2: Check oil after 5 hours of operation CUSTOMER RESPONSIBILITIES T ABLE MAINTENANCE T ASK Before each use X Every 25 Hours or Every Season See Note 2 X Every 50 H ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 15

    15 — ENG STORAGE If you are going to store your generator for more than 30 days, use the following information as a guide to prepare the generator for storage. Never store generator with fuel in the tank indoors or in enclosed, poorly ventilated areas, where fumes can reach an open flame, spark or pilot light as on a fur nace, water heater , clot ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 16

    16 — ENG Never exceed the rated capacity of your generator . Serious damage to the generator or appliance could result from an overload. 1. S tarting and running wattage requirements should always be calculated when matching a generators wattage capacity to the appliance or tool. 2. There are two types of electrical appliances that can be powered ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 17

    17 — ENG ST AR TING W A TT AGE REQUIREMENTS 1. Some appliances and tools will list on the motor name plate the starting and running voltage and amperage requirements. Use the following formula to convert voltage and amperage to wattage: V olts X Amp = W atts 120 volts x 10 amps = 1200 watts 2 . T o determine the approximate starting wattage requi ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 18

    18 — ENG HOUSEHOLD W A TT AGE CALCULA TOR W A TT AGE CALCULA TIONS APPLIANCE OR LOAD DEVICE* REFRIGERA TOR/ FREEZER 800 SMALL REFRIGERA TOR AIR COND.(ROOM) SUMP PUMP 1/2 HP 600 TELEVISION CAUTION !! HOT PLA TE MICROWA VE SP ACE HEA TER 2400 1000 3 2 LIGHTING 60 WA TT BULBS 75 WA TT BULBS 100 WA TT BULBS 300 WA TT BULBS ELECTRIC LOAD GRAND TOT AL ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 19

    19 — ENG TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Engine will not start No electrical output Repeated circuit breaker tripping Generator overheating No auto idle DC does not have power with the circuit breaker depressed 1. Low on fuel or oil. 2. Ignition switch in "Off" position. 3. Faulty spark plug. 4. Choke in wrong position. 5 ...

  • Porter-Cable H450CS, CH350CS, H650CS - page 20

    20 — ENG EN G IN E GA S WA T T AGE WIRI NG EN GI N E Allow the g e nerato r to ru n 5 minutes at no load f o r the eng ine a nd the g enhea d to s ta b iliz e. OP ERA T I ON M ake su r e t h e ade qu a t e siz e o f e xt e n sio n co r d i s u s e d. Re fe r t o t h e G r o u n din g Ins truc ti ons /E x t e ns i on Cord s e ct i on of the o w ne ...

Fabbricante Porter-Cable Categoria Portable Generator

I documenti che otteniamo dal fabbricante del dispositivoPorter-Cable H450CS, CH350CS, H650CS possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Porter-Cable
- manuali per l’uso H450CS, CH350CS, H650CS
- schede prodotto Porter-Cable
- opuscoli
- o etichette energetiche Porter-Cable H450CS, CH350CS, H650CS
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Porter-Cable H450CS, CH350CS, H650CS.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Porter-Cable H450CS, CH350CS, H650CS, manuali di manutenzione, brevi manuali o manuali utente Porter-Cable H450CS, CH350CS, H650CS. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Porter-Cable H450CS, CH350CS, H650CS.

Manuali per l’uso simili

Manuale completo del dispositivo Porter-Cable H450CS, CH350CS, H650CS, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Porter-Cable H450CS, CH350CS, H650CS dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Porter-Cable H450CS, CH350CS, H650CS.

Il manuale per l’uso completo Porter-Cable, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Porter-Cable H450CS, CH350CS, H650CS - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Porter-Cable H450CS, CH350CS, H650CS, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Porter-Cable H450CS, CH350CS, H650CS che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Porter-Cable H450CS, CH350CS, H650CS - che ci dovrebbe aiutare nei primi passi durante l'uso Porter-Cable H450CS, CH350CS, H650CS
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Porter-Cable H450CS, CH350CS, H650CS
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Porter-Cable H450CS, CH350CS, H650CS in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Porter-Cable H450CS, CH350CS, H650CS?

Utilizza il modulo sottostante

Se non hai risolto il problema con Porter-Cable H450CS, CH350CS, H650CS con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Porter-Cable H450CS, CH350CS, H650CS è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)