    METROLOGIC INSTRUMENTS, INC. MS7600 Horizon ™ Ser ies Installation and Us er’s Guide ...

  • Metrologic Instruments MS7620 - page 2

    ...

  • Metrologic Instruments MS7620 - page 3

    iii T ABLE OF C ONTENTS Introducti on........................................................................................................... 1 Scanner and A ccessori es ..................................................................................... 2 Before Installing Your MS 7600 .......................................................... ...

  • Metrologic Instruments MS7620 - page 4

    1 I NTRODUCTION The MS7600 Horizon ™ series is Metrologic’s next generation in -c ounter laser bar code scanner. This compact, hands-free scanner is desig ned with a dense 20-line omnidirectiona l scan pattern that helps provide fast, efficient throughput with a high first pass read rate. The MS7600 is equipped with a multit ude of standard fea ...

  • Metrologic Instruments MS7620 - page 5

    2 S CANNER AND A CCESSORIES B AS IC K IT Part # Description MS7600 Horizon ™ Series Scanner 00-02407B MetroSelect ® Programmin g Guide 00-02870B MS7600 Horizon Series Installatio n and User’s Guide 52-52511A 24” EAS cable Guides also available for download at www.metrologic.com. O PTIONAL A CCESSORIES Part # Description 46-46640 Point of Sal ...

  • Metrologic Instruments MS7620 - page 6

    3 S CANNER AND A CCESSORIES (C ONTINUED ) O PTIONAL A CCESSORIES Part # Description AC to DC Power Transformer - Regulated 5.2V@650 mA output 45-45593 120V United States 45-45591 220V – 240V Continental Europ ean 45-45592 220V – 240V United Kingdom 46-46641 Stainless Steel Trim Ring R EPLACEMENT P ARTS Part # Description Caution Window types (S ...

  • Metrologic Instruments MS7620 - page 7

    4 B EFORE I NSTALLING Y OUR MS7600 When mounting the MS7600 or replac ing the Top Plate: D O N OT Press on the window. Figure 2 Lift the Top plate straight up to remove. There is no hardware required to remove or replace the top cover. See caution on page 3. There are two installation tabs under the top cover that can be used to place the unit into ...

  • Metrologic Instruments MS7620 - page 8

    5 M OUNTIN G THE MS7600 S ERI ES There are thr ee options for moun ting y our MS 7600. Option “A” us es a she lf to support the un it. Op tion B le ts the u nit hang free in the counter t op. Option C lets the unit hang fre e in the counter top with t he use of a sta inless st eel trim ring for support. The tr im ring ( MLPN 46-46641) is an opt ...

  • Metrologic Instruments MS7620 - page 9

    6 M OUNTIN G THE MS7600 S ERI ES O PTION B: Free Hanging Support Figure 8: Package Flow (right) Figure 9: Specifications for free hanging support. Figure 10: In sta llation Tabs ...

  • Metrologic Instruments MS7620 - page 10

    7 M OUNTIN G THE MS7600 S ERI ES O PTION C: Trim Ring ( ML PN 46-46641, Addit ional Purc hase) Figure 11: Counter Top Opening for Trim Ring ( MLPN 46-46641) Figure 12: Trim Ring ( MLPN 46-46641) Installation ...

  • Metrologic Instruments MS7620 - page 11

    8 Figure 14: Keyboard Wedge Interfa ces I NSTALLATION FOR K EYBOARD W EDGE I NTERFACE 1. Turn off the ho st sys tem. 2. Disconne ct the keyboard fro m the ho st. 3. Connect th e PowerLink cable to t he 2 nd jack fro m the top of the M S7600. 4. Connect the “Y ” end of the PowerLink c able to the keyboar d and the key board port on the ho st. If ...

  • Metrologic Instruments MS7620 - page 12

    9 Figure 15: Stand-Alone Keyboard In terface I NSTALLATION FOR S TAND -A LON E K EYBOARD I NTERFACE 1. Turn off the ho st sys tem. 2. Disconne ct the keyboard fro m the ho st. 3. Connect th e PowerLink cable to t he 2 nd jack from th e top of the M S7600. 4. Connect the oth er end of the PowerLi nk cable to the keyboa rd port on the ho st. Before c ...

  • Metrologic Instruments MS7620 - page 13

    10 Figure 17: US B, In te rface I NSTALLATION FOR USB I NTERFACE 1. Turn off the ho st sys tem. 2. Determine if your appl ication requires USB Key board communic ation prot ocols or USB Point of Sale com munica tion protocols. 3. If you require USB Ke yboard communic ation prot ocols, ski p to step 4. If you require USB Po int of Sale communic atio ...

  • Metrologic Instruments MS7620 - page 14

    11 I NSTALLATION FOR USB I NTERFACE Manufacturer s Note: Plugging the scanner into the USB port of th e PC does not guara ntee tha t scanned inf ormatio n will ap pear at the PC . A softw are driver and correct configurat ion settin g are al so req uired f or proper communic ation to occur. 6. Scan the Enabl e USB Defaults bar code to conf igur e t ...

  • Metrologic Instruments MS7620 - page 15

    12 Figure 18: RS232 or Light Pen Interfa ce I NSTALLATION FOR RS232 OR L IGHT P EN I NTERFACES 1. Turn off the ho st sys tem. 2. Connect th e PowerLink cable into the 1 st jack dow n from the t op of the MS7600. 3. Connect the oth er end of the PowerLink c able to the host. Before cont inuing ver ify that the PowerLink c able is c onnecte d to the ...

  • Metrologic Instruments MS7620 - page 16

    13 I NSTALLATION FOR RS232 OR L IGHT P EN I NTERFACES Step 7, page 12 continued. For RS232 C ommunicat ion: Scan 1 st ³9 9 9 9 9 8 Recall Defaul ts Scan 2 nd ³4 1 5 5 5 4 Enable RS-232 For Light Pen C ommunic ation: Scan 1 st ³9 9 9 9 9 8 Recall Defaul ts Scan 2 nd ³4 1 5 5 2 4 Enable Li ght Pen/W and ...

  • Metrologic Instruments MS7620 - page 17

    14 Figure 19: RS232/IBM, Interface I NSTALLATION FOR IBM 46 XX I NTERFACE 1. Turn off the host system. 2. Connect the MVC cable to the 1 st jack down from the top of the MS7600. 3. Connect the other end of the MVC cable to the host. Before continuing verify that the MVC cable is connected to the appropriate interface jack on the scanner. An incorre ...

  • Metrologic Instruments MS7620 - page 18

    15 Figure 13: OCIA, Interface I NSTALLATION FOR OCIA I NTERFACE 1. Turn off the host system. 2. Connect the MVC cable to the 2 nd jack down from the top of the MS7600. 3. Connect the other end of the MVC cable to the host. Before continuing verify that the MVC cable is connected to the appropriate interface jack on the scanner. An incorrect cable c ...

  • Metrologic Instruments MS7620 - page 19

    16 I NSTALLATION OF A S ECONDARY S CANNER 1. Turn off the host system. 2. Connect the round end of the PowerLink RS232 AUX cable [ MLPN 54-5466 7A] to the RS232 jack of the secondary scanner ( see figure 20 ). 3. Connect the other end of the Po we rLink RS232 AUX cable into the 3 rd jack down from the top of the MS7600 . The following Metrologic sc ...

  • Metrologic Instruments MS7620 - page 20

    17 I NSTALLATION OF A S ECONDARY S CANNER 11. Scan the follo wing bar code to conf igure the auxiliar y port on the MS7600 to accept a Metrologic scanner as the secondary sc anner. The following bar codes do not apply when using an MS6720 as a secondary scanner. Contact a Metrolo gic representative for additional information on the MS6720. If the s ...

  • Metrologic Instruments MS7620 - page 21

    18 I NSTALLATION OF A S ECONDARY S CANNER Figure 20: Connector Orientation (Top) Secondary Scanner Setup (Bottom) ...

  • Metrologic Instruments MS7620 - page 22

    19 S CANNER P ARTS Figure 21: Scanner Parts n Output Window (Laser Ape rture) o Amber LED (Located U nder Window) p Red LED (Locat ed Under Window) q Speaker r Cable Conne ction Area s Stainless Ste el Top (M S7625 un its only) t Package Flow Indicator Arrow Head u Rubber Conne ctor Plug v EAS Deactivation A ntenna Conne ctor n s q p o r o p t u v ...

  • Metrologic Instruments MS7620 - page 23

    20 M AINTENANCE Smudges and dirt can interfere with the pr oper scanning of a bar code. Therefore, t he output window w ill need occasi onal c leaning. For the M S7600 glass w indow : 1. Spray glass cleaner onto li nt free, n on-abras ive clean ing clo th. 2. Gently w ipe the sca nner wind ow . For the M S7600 red w indow: 1. Use mild soa p and w a ...

  • Metrologic Instruments MS7620 - page 24

    21 S CANNER L ABELS Each scanner has a label on the bottom of the unit. T he label contains information such as the model number, dat e of manufacture, serial number, and caution information. An additional cauti on label is located under the top plate. The following are examples of these l abels. Figure 23: Label Locations ...

  • Metrologic Instruments MS7620 - page 25

    22 A UDIBLE I NDICATORS When the M S7600 scan ner is in operat ion, it provides au dible f eedbac k. These sounds ind icate th e statu s of the scanner. Ei ght sett ings are availabl e for the tone of the be ep (norma l, 6 alte rnate to nes and no tone) plus thr ee volume settings. T o chang e the ton e or volume , refer to t he Chang ing the Be ep ...

  • Metrologic Instruments MS7620 - page 26

    23 V ISUAL I NDICATORS There is a red LED an d amber LED on the front of the M S7600. W hen the scan ner is on, the flash ing or c onstant illuminat ion of t he LEDs indicate s the st atus of the curre nt sca n and the scan ner. Figure 24: LEDs No Red or Amber LED The LEDs w ill not be illumi nated if the sc anner is not receivin g power fro m the ...

  • Metrologic Instruments MS7620 - page 27

    24 F AILURE M ODES Figure 25: LEDs Flashing A mber and One Raz zberry Tone This ind icates the scann er has ex perien ced a laser su bsystem f ailure. R eturn the unit for r epair at an authorized servic e center. Flashing R e d and Amber and Tw o Ra z zb er r y Tones This ind icates the scann er has ex perien ced a motor failure. Return the unit f ...

  • Metrologic Instruments MS7620 - page 28

    25 C HANGING THE B EEPER T ONE & V OLUME Changing the Beeper Tone Beeper tone s may be pr ogramm ed directly or incr emental ly using t he f ollow ing bar code. T he new tone will be heard f ollow ed by a sh ort pause. T w o more new tones w ill be hear d signi fying the n ew setting has b een stor ed in m emory. T he silent (no be ep) tone is ...

  • Metrologic Instruments MS7620 - page 29

    26 P OW E R S AVE M ODES AND IR D ETECT ION The MS 7600 has five programm able p ower sav e modes . Refer to t he MetroSelect Pro gramming G uide for add itional inform ation on P ower Sav e Modes. 1. Blink Power Save Mode: Blinks the l aser OFF & O N after a progra mmed perio d of non-us e. When the scanner r ecognize s a bar code it w ill ex ...

  • Metrologic Instruments MS7620 - page 30

    27 P OW E R S AVE M ODES AND IR D ETECT ION Figure 27: IR A ctivation Area Parall el to Pa ckage Flow Specificat ions are subject t o change without notice. ...

  • Metrologic Instruments MS7620 - page 31

    28 S CAN V OLUME S PECIFICATI ONS (B ASED ON 100% UPC B AR C ODES ) Figure 28: Scan Volume in Pl ane Perpendicular to Fl ow Figure 29: Scan Volume in Pl ane Parallel to Flow Specificat ions subject to c hange without notice. ...

  • Metrologic Instruments MS7620 - page 32

    29 D EPTH OF F IELD BY M IN IM UM B AR C ODE E LEMENT W IDTH (B ASED ON 100% UPC B AR C ODES ) Figure 30: Depth of Field Perpendic ular to Flow Minimum Ba r Code Eleme nt Wi dth ABCD E mm .13 .19 .26 .33 .48 mils 5.2 7.5 10.4 13 19 Specificat ions subject to c hange without notice. ...

  • Metrologic Instruments MS7620 - page 33

    30 T ROUBLE SHOOTIN G G UIDE The follow ing guid e is for refere nce pur poses only. Co ntact a M etrologic representativ e at 1-80 0-ID-M ETRO or 1-800-436-387 6 to pres erve the li mited warranty terms. MS7600 S ERIES T ROUBLESHOOTING G UIDE SYMPTOMS POSSIBLE CAUSE(S) SOLUTION All Interfaces No LEDs, beep or motor spin. No power is b eing supplie ...

  • Metrologic Instruments MS7620 - page 34

    31 T ROUBLE SHOOTIN G G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Scanning a particular symbology that i s not enabled. UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read ha s been select ed. The unit pow ers up, but does not scan and /or beep. The sca ...

  • Metrologic Instruments MS7620 - page 35

    32 T ROUBLE SHOOTIN G G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The bar co de may have been pri nted incorrect ly. Check if it is a che ck digit/ch aracter/or bord er problem. The scanner is not configured c orrectly for this type of bar code. Check if check dig its are set properly. Scanner beeps at some bar codes a nd NOT for other ...

  • Metrologic Instruments MS7620 - page 36

    33 T ROUBLE SHOOTIN G G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Everything works ex cept for a couple o f characters. These ch aracter s may not be support ed by that country ’s key look up table. Try operating the scanner in A lt mode. RS-232 Only The unit is transmitting each charac ter. Configurati on is n ot correct. Increase t ...

  • Metrologic Instruments MS7620 - page 37

    34 T ROUBLESHOOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CA USE(S) SOLUTION Characters are being dropped. Intercharacter delay needs to be added to the transmitted output. Add some intercharacter delay to the transmitted output by using the MetroSelect ® Programming Guide ( MLPN 00-02407A-1 & -2). Aux port operation with a ny interface Troub ...

  • Metrologic Instruments MS7620 - page 38

    35 D ESIGN S PECIFICATIONS MS7600 S ERIES D ESIGN S PECIFICATIONS O PERATIONAL Light Source: VLD 650 ± 10 nm Laser Power: 1.1 mW maximum Depth of Field: 0 mm to 203.2 mm (0”- 8.0”) for 0.33 mm (13 mil) bar code Width of Scan Field: 85 mm (3.3”) @ 0 mm (0.0”); 142 mm (5.6”) @ 124 mm (4.9”) Scan Speed: 2000 scans/second Scan Pattern: 5 f ...

  • Metrologic Instruments MS7620 - page 39

    36 D ESIGN S PECIFICATIONS (C ONTINUED ) MS7600 S ERIES D ESIGN S PECIFICATIONS E LECTRICAL Input Voltage: 5.2VDC ± 0.25V Power: 2.6 W Operating Current: 500 mA Laser Off Power Save Mode = < 350 mA Standby Current: Laser/Motor Off Power Save Mode = <165 mA DC Transformers: Class II; 5.2 V @ 650 mA Laser Class: IEC 60825-1:19 93+A1:1997+A2:20 ...

  • Metrologic Instruments MS7620 - page 40

    37 RS232 D EM ONSTRAT ION P ROGRAM If an RS232 scanner is not communic ating w ith your IBM comp atible PC, key in the follow ing BASIC pr ogram to tes t that the c ommunicat ion port and scanner are w orkin g. This progr am is for demo nstratio n purpo ses only. It is only intende d to prov e that cabling is corr ect, the com p ort is w orking, an ...

  • Metrologic Instruments MS7620 - page 41

    38 A PPLICATIONS AND P ROTOCOLS The mode l number on each s canner includ es the scanner number and f actory default com munica tions p rotocol. S CANNER V ERSION I DENTIFIE R C OMMUNIC A TION P ROTOCOL ( S ) 7620 7625 13 RS232, IBM 46x x, OCIA, Aux 7620 7625 37 RS2 32, Ligh t Pen , Keyb oar d W edge, Stand-Alone Key board, USB, Aux The MS 7600 wit ...

  • Metrologic Instruments MS7620 - page 42

    39 D EFAULT S ETTINGS Many functions of t he sca nner ca n be "pro gramme d" - that is, ena bled or disabled. T he sca nner is shipped fro m the fa ctory pro grammed to a set of default cond itions. The def ault para meter of the scann er has a n asteri sk ( * ) in the charts o n the follow ing page s. If an a steris k is not in the def a ...

  • Metrologic Instruments MS7620 - page 43

    40 D EFAULT S ETTINGS (C ONTI NUED ) P A RAM ETER D E FAUL T OCIA RS-232 L IGHT P EN IBM 46XX KBW USB Bars High as Scanned 9 Spaces High as Scanned 9 DTS/SIEM ENS 9 DTS/NIXDORF * 9 NCR F 9 NCR S 9 Poll Light Pen Source 9 Beeper Tone Norm al 9999 9 9 Beep/Transm it Sequence Befor e Transm it 9999 9 9 Beeper Volum e Loudest 9999 9 9 Communication T i ...

  • Metrologic Instruments MS7620 - page 44

    41 D EFAULT S ETTINGS (C ONTI NUED ) P A RAM ETER D E FAUL T OCIA RS-232 L IG HT P EN IBM 46XX KBW USB Number of Scan B uffers 1 99 999 9 Transmit EAN-8 Check D igit * 99 99 9 Transmit EAN-13 Check D igit * 99 9 9 9 Transmit UPC-A Che ck Digit * 99 999 9 Transmit UPC-E Che ck Digit 9 999 9 Expand UP C-E 99 999 9 Convert UPC-A to EAN-13 99 9 9 9 UPC ...

  • Metrologic Instruments MS7620 - page 45

    42 D EFAULT S ETTINGS (C ONTI NUED ) P A RAM ETER D E FAUL T OCIA RS-232 L IG HT P EN IBM 46XX KBW USB UPC Suffix 99 9 Transmit AIM ID Characters 99 9 STX Pref ix 99 9 ETX Suff ix 99 9 Carriage Re turn * 99 9 Line Feed - disa bled by default in KBW * 99 9 Tab Prefix 99 9 Tab Suffix 99 9 "DE" Disable Com mand 99 "FL" Laser Enab l ...

  • Metrologic Instruments MS7620 - page 46

    43 D EFAULT S ETTINGS (C ONTI NUED ) P A RAM ETER D E FAUL T OCIA RS-232 L IGHT P EN IBM 46XX KBW USB Coupon Code 128 99 as code 39 99 9 Programm able Code Lengths 7 avail. 999 99 9 Programm able Prefix Characters 10 avail. 99 9 Suffix Characte rs 99 9 Prefixes for in dividual Code Types 99 9 Edit in g 99 9 99 9 Inter Scan-C ode Delay Programm able ...

  • Metrologic Instruments MS7620 - page 47

    44 D EFAULT S ETTINGS (C ONTINUED ) Default settings for “ Aux ” interface The secondary scann er and the MS7600 always communicate via RS 232. Data is relayed to the host via various primar y interfaces. P ARAM ET ER D EFAULT OCIA RS-232 L IGHT P EN IBM 46XX KBW USB Aux Baud Rate 38400 99 99 99 Aux parity space 99 9 999 Aux data bits 7 99 99 9 ...

  • Metrologic Instruments MS7620 - page 48

    45 S CANNER AND C ABLE T ERMINATIO NS Scanner Pinout Connections The MS7600 s canner i nterface s terminate to 10-pi n modular ja cks located on the back of the unit. T he ser ial # labe l indic ates th e model nu mber of t he sca nner. Figure 31: Scanner Interface Ports MS762x- 13 OCIA MS762x- 13 IBM 46xx Pin Function Pin Function 1 Ground 1 Groun ...

  • Metrologic Instruments MS7620 - page 49

    46 S CANNER AND C ABLE T ERMINATIO NS (C ONTINUED ) Figure 32: Scanner Interface Ports MS762x- 37 Keyboar d W edge, Stand-Ke yboard or USB MS762x- 37 RS- 232 o r Li ght Pen Pin Function Pin Function 1 Ground 1 Ground 2 USB D- 2 RS-232 T ransmit Out put 3 USB D+ 3 RS-232 Receive In put 4 PC Data 4 RTS Output 5 PC Clock 5 CTS Input 6 KB Clock 6 DTR I ...

  • Metrologic Instruments MS7620 - page 50

    47 S CANNER AND C ABLE T ERMINATIO NS (C ONTINUED ) Cable Connector Configurations (Host End) PowerLink Cable MLPN 54-54xxx* Pin Function 1 Shield Ground 2 RS-232 Transmit O utput 3 RS-232 Receive In put 4 DTR Input 5 Power/Signal Grou nd 6 Reserved 7 CTS Input 8 RTS Output 9+ 5 V D C xxx* speci fies connection to the host USB PowerL ink Cable ( ML ...

  • Metrologic Instruments MS7620 - page 51

    48 S CANNER AND C ABLE T ERMINATIO NS (C ONTINUED ) Cable Connector Configuration The Po werLink c able is term inated with a 5-pin DI N fem ale connector on one end, an d a 6-pi n mini DIN m ale on t he other. Metrolog ic will su pply an ada pter ca ble with a 5-pin DIN m ale connec tor on one end and a 6-p in mini DIN f emale c onnector on the ot ...

  • Metrologic Instruments MS7620 - page 52

    49 L IMITED W ARRANTY The MS7600 Series scanners are manufact ured by Metrologic at its Blackwood, New Jersey, U.S. A. facility. The MS7600 Series scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS7600 Series scanners are free of all defect s in material, workmanship and design ...

  • Metrologic Instruments MS7620 - page 53

    50 N OTICES This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interfer ence, and (2) this device must accept any interferen ce received, including interference that may cause undesired operation. This equipment has been tested and foun d to comply with the ...

  • Metrologic Instruments MS7620 - page 54

    51 N OTICES (C ONTINUED ) Attent ion L'emploi de commandes, réglag es ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essa yer d'entretenir lui-même le scanner ou le las er. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N& ...

  • Metrologic Instruments MS7620 - page 55

    52 P ATENTS “Patent Infor mation This M ETRO LOGIC product may be cov ered by on e or more of the f ollow ing U.S. Patents: U.S. Patent No.; 4,960,985; 5,081, 342; 5,2 16,232; 5,55 7,093; 5 ,627,35 9; 5,637, 852; 5,661,292; 5,777,315; 5,789,73 1; 6,02 9,894; 6, 209,789 ; 4,360,798; 4,369, 361; 4,3 87,297; 4,46 0,120; 4 ,496,83 1; 4,593, 186; 4,60 ...

  • Metrologic Instruments MS7620 - page 56

    53 I NDEX A Accessorie s .................................. 2 Adapter ....................................... 48 Audible ........................................ 22 Autodiscr iminates ....................... 35 B Bar Code .............................. 28, 29 Beep ..................................... 22, 40 C Cable .......... 2, 12, 19, 33-35, 45- ...

  • Metrologic Instruments MS7620 - page 57

    54 I NDEX T Termination ................................. 35 Transformers .............................. 36 Troublesh ooting ...30, 31, 32 , 33, 34 U USB ............................................ 10 V Ventilation ................................... 36 Visual .......................................... 23 Voltage .................................. ...

  • Metrologic Instruments MS7620 - page 58

    ...

  • Metrologic Instruments MS7620 - page 59

    August 2002 Printed in the USA 00 - 02870 B ...

Fabbricante Metrologic Instruments Categoria Scanner

I documenti che otteniamo dal fabbricante del dispositivoMetrologic Instruments MS7620 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Metrologic Instruments
- manuali per l’uso MS7620
- schede prodotto Metrologic Instruments
- opuscoli
- o etichette energetiche Metrologic Instruments MS7620
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Metrologic Instruments MS7620.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Metrologic Instruments MS7620, manuali di manutenzione, brevi manuali o manuali utente Metrologic Instruments MS7620. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Metrologic Instruments MS7620.

Manuale completo del dispositivo Metrologic Instruments MS7620, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Metrologic Instruments MS7620 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Metrologic Instruments MS7620.

Il manuale per l’uso completo Metrologic Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Metrologic Instruments MS7620 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Metrologic Instruments MS7620, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Metrologic Instruments MS7620 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Metrologic Instruments MS7620 - che ci dovrebbe aiutare nei primi passi durante l'uso Metrologic Instruments MS7620
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Metrologic Instruments MS7620
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Metrologic Instruments MS7620 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Metrologic Instruments MS7620?

Utilizza il modulo sottostante

Se non hai risolto il problema con Metrologic Instruments MS7620 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Metrologic Instruments MS7620 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)