Manuale per l’uso Dimplex DFI2309

16 pagine 0.34 mb
Scarica

Vai alla pagina of 16

Summary
  • Dimplex DFI2309 - page 1

    PARTS AND SERVICE MANUAL FOR THE 23” INSERT FIREPLACE MODEL NUMBER: DFI2309 ...

  • Dimplex DFI2309 - page 2

    TABLE OF CONTENTS O P E R A T I O N P A G E 1 PARTS DRAWING PAGE 3 P A R T S L I S T P A G E 4 WIRING DIAGRAM PAGE 5 LIGHT BULB REPLACEMENT PAGE 6 MAIN ON/OFF SWITCH REPLACEMENT PAGE 8 LOW HEAT ON/OFF SWITCH REPLACEMENT PAGE 9 HIGH HEAT ON/OFF SWITCH REPLACEMENT PAGE 10 FLAME MOTOR/FLAME ROD REPLACEMENT PAGE 11 HEATER ASSEMBLY REPLACEMENT PAGE 12 L ...

  • Dimplex DFI2309 - page 3

    1 DFI2309 OPERATION MAIN ON/OFF FLAME ON/OFF SWITCH The ON/OFF switch supplies power to all unit functions. When this switch is in the ON position the flame effect operates without heat. LOW HEAT SWITCH The LOW HEAT ON/OFF SWITCH supplies power to the heat er fan and the heater element. When the switch is in the ON position the heater operates on L ...

  • Dimplex DFI2309 - page 4

    2 DFI2309 REMOTE CONTROL The remote control has a range of approxim ately 50ft. (15.25m) it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with one of 243 i ndependent frequencies to prevent interference with other units. The frequency designation is indicate d on the back of the t ...

  • Dimplex DFI2309 - page 5

    3 DFI2309 10 9 6 4 11 1 2 3 7 8 5 12 ...

  • Dimplex DFI2309 - page 6

    4 DFI2309 REPLACEMENT PARTS 23” FIREPLACE INSERT REPLACEMENT PART REPLACEMENT PART NO. 1. MAIN ON/OFF SWITCH 2800090100RP* 2. LOW HEAT ON/OFF SWITCH 2800090100RP* 3. HIGH HEAT ON/O FF SWITCH 2800090100RP* 4. CORDSET 4100090101RP 5. HEATER ASSEMBLY 2200490300RP 6. CUTOUT 2300270200RP 7. MIRROR 5900350100RP 8. LOGSET 0438200200RP 9. FLICKER MOTOR 2 ...

  • Dimplex DFI2309 - page 7

    5 DFI2309 WIRING DIAGRAM ...

  • Dimplex DFI2309 - page 8

    6 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. Light bulbs need to be replaced when you notice a dark section o ...

  • Dimplex DFI2309 - page 9

    7 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. BULB REQUIREMENTS Quantity 2 clear chandelier or candelabra bulb ...

  • Dimplex DFI2309 - page 10

    8 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE MAIN ON/OFF SWITCH 1. Remove the trim and firebox fro ...

  • Dimplex DFI2309 - page 11

    9 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE LOW HEAT ON/OFF SWITCH 1. Remove the trim and firebox ...

  • Dimplex DFI2309 - page 12

    10 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HIGH HEAT ON/OFF SWITCH 1. Remove the trim and fireb ...

  • Dimplex DFI2309 - page 13

    11 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE FLAME MOTOR/FLAME ROD 1. Remove the trim and firebox ...

  • Dimplex DFI2309 - page 14

    12 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATER ASSEMBLY 1. Remove the trim and firebox from ...

  • Dimplex DFI2309 - page 15

    13 DFI2309 If unit was operating prior to servicing allo w at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE LIGHT HARNESS 1. Remove the trim and firebox from m ...

  • Dimplex DFI2309 - page 16

    14 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE POWER CORD 1. Remove the trim and firebox from mante ...

Fabbricante Dimplex Categoria Indoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoDimplex DFI2309 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Dimplex
- manuali per l’uso DFI2309
- schede prodotto Dimplex
- opuscoli
- o etichette energetiche Dimplex DFI2309
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Dimplex DFI2309.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Dimplex DFI2309, manuali di manutenzione, brevi manuali o manuali utente Dimplex DFI2309. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Dimplex DFI2309.

Manuali per l’uso simili

Manuale completo del dispositivo Dimplex DFI2309, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Dimplex DFI2309 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Dimplex DFI2309.

Il manuale per l’uso completo Dimplex, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Dimplex DFI2309 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Dimplex DFI2309, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Dimplex DFI2309 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Dimplex DFI2309 - che ci dovrebbe aiutare nei primi passi durante l'uso Dimplex DFI2309
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Dimplex DFI2309
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Dimplex DFI2309 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Dimplex DFI2309?

Utilizza il modulo sottostante

Se non hai risolto il problema con Dimplex DFI2309 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Dimplex DFI2309 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)