Manuale per l’uso Honeywell 121371B

16 pagine 0.7 mb
Scarica

Vai alla pagina of 16

Summary
  • Honeywell 121371B - page 1

    PRODUCT DATA 68-0040-04 Immersion W ells and Compression Fittings FOR T EMPERATURE CONTROLLERS APPLICATION Immersion wells, compression fittings and element hold ers are used with Aquastat® T emperature Controllers to hold the temperature sensing bulb in the controlled medium. Immersion wells and compre ssion fittings also prevent leakage of the c ...

  • Honeywell 121371B - page 2

    IMMERSION WELLS AND COMPRESSION FITTINGS 68-0040—04 2 ORDERING INFORMATION When purchasing replacement and modernizat io n products from your TRADELINE® whol esaler or distributor , refer to the TRADELINE® Catalog or price sheets for complete ordering number . If you have additional questions, need further information, or w oul d like to commen ...

  • Honeywell 121371B - page 3

    IMMERSION WELLS A ND COMPRESSION FITTINGS 3 68-0040—04 Fig. 2. I mmersion wel l dimens ions and c omponents. INSULA TION DEPTH INSULA TION DEPTH INSULA TION DEPTH INSULA TION DEPTH INSULA TION DEPTH INSULA TION DEPTH INSULA TION DEPTH INSERTION/MAX BULB LENGTH INSERTION/MAX BULB LENGTH INSERTION/MAX BULB LENGTH INSERTION/MAX BULB LENGTH INSERTION ...

  • Honeywell 121371B - page 4

    IMMERSION WELLS AND COMPRESSION FITTINGS 68-0040—04 4 T able 1. Coppe r Immersion Wells. T able 2. St ainless Steel, Mild Steel, and Mo nel Immersion Wells. Spud in in. x 14 NPT Shell ID/ Bulb Diameter Insertion/ Max Bulb Length Insulation Depth Capillary Diameter Includes Part Number 1/2 3/8 3 1-1/2 5/64 121371 Mounting Clamp 121371A — — 123 ...

  • Honeywell 121371B - page 5

    IMMERSION WELLS A ND COMPRESSION FITTINGS 5 68-0040—04 T able 3. Capillary Compression Fittings. Material Spu d Maximum Bulb Diameter Insulation Depth C apillary Diameter Part Number Brass 1/2-14 NPT 1/2 in. 1-5/16 i n. 5/64 in. 104484A 1/8 in. 7617M 1-1/2 in. 5/64 in. 104484C 2 in. 5/64 in. 7617ABY 3/4-14 NPT 1-5/8 in. 5/64 in. 104484B 1 1/16 in ...

  • Honeywell 121371B - page 6

    IMMERSION WELLS AND COMPRESSION FITTINGS 68-0040—04 6 T able 5. Immersion Well Accessorie s . Description Appli cation Size in in. (except where noted) Part Number Mounting clamp Holds capillary in p lace on 123869A-123872A; 122554A,B; 12255A,B,D,E; and 138134B-F Immersio n Wells. 1/2 or 3/4 in. well spud; 5/64 capillary Sp r i n g c l i p Holds ...

  • Honeywell 121371B - page 7

    IMMERSION WELLS A ND COMPRESSION FITTINGS 7 68-0040—04 GENERAL INFORMATION Immersion Wells An immersion well consists of a metal tube, called the well shell, closed on one end. A well spud externally thre aded to fit standard boiler tappings is welded or brazed on the open end. See Fig. 1. The well is inserte d into the tank and the temperature s ...

  • Honeywell 121371B - page 8

    IMMERSION WELLS AND COMPRESSION FITTINGS 68-0040—04 8 threaded end of the spud can extend into the controlled medium. Consider this additional length whe n determining how far the well extends into the controlled medium. The length of the well shell starting at the end of the spud defines the insertion length. This is the active part of the well ...

  • Honeywell 121371B - page 9

    IMMERSION WELLS A ND COMPRESSION FITTINGS 9 68-0040—04 WARNING Electrical Shock Hazard or Equipment Dam age Hazard. Can cause sever injury , death or short equipme nt circuitry . Disconnect all power su pplies before installation. Most equipment manufacture rs provide a tapping for temperature controller sensin g element insertion. The tapping sh ...

  • Honeywell 121371B - page 10

    IMMERSION WELLS AND COMPRESSION FITTINGS 68-0040—04 1 0 Fig. 6. Mounting spring clip into well spud . Securing Bulb in Wells with Setscrew Wells with a spud setscrew are designed for use with controllers that have armored capi llary with a brass collar at the bulb end of the armor . The setscrew tightens against the brass collar . See Fig. 7. The ...

  • Honeywell 121371B - page 11

    IMMERSION WELLS A ND COMPRESSION FITTINGS 11 68-0040—04 Fig. 1 1. Mounting sensin g bulb and 31 12 66D Bulb Holde r in duct. NOTE: Dimensions shown in in. (mm). Duct Mounting with Capillary Compression Fitting In some duct-mount application, it is desira ble to use a compression fitting to reduce air l eakage at the sensing element location. For ...

  • Honeywell 121371B - page 12

    IMMERSION WELLS AND COMPRESSION FITTINGS 68-0040—04 1 2 Bulb Shields A bulb mounted outdoors requires protection of a bulb shield. 1. Expose the bulb to represent ative air temperature but not direct sunlight. 2. Mount it high enough so: a. Accumulated snow , leaves or other debris can- not obstruct air circulation around it. b. Children cannot r ...

  • Honeywell 121371B - page 13

    IMMERSION WELLS A ND COMPRESSION FITTINGS 13 68-0040—04 CHECKOUT When installation is complete, check it as follows: 1. Visually inspect the fittings in hydronic applications for leakage. 2. If necessary , tighten these fittings. 3. Ensure excess capillary is coiled beneath the controller case. 4. Ensure proper operation by observing the system t ...

  • Honeywell 121371B - page 14

    IMMERSION WELLS AND COMPRESSION FITTINGS 68-0040—04 1 4 T able 8. Cross Referenc e . Old Part Number Description Replacem ent Part Number Notes 121371G Immersion well. Bra ss, 1/2-14 N PT , 1-1/2 in. insulation, 6-1/2 in. insertion, includes 121371 mounting clamp. None — 121371N Immersion well. Copp er , 3/4-14 NP T , 3 in. insulation, 3 in. in ...

  • Honeywell 121371B - page 15

    IMMERSION WELLS A ND COMPRESSION FITTINGS 15 68-0040—04 ...

  • Honeywell 121371B - page 16

    Automation and Co ntrol Solutions Honeywell Internation al Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Dri ve North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com IMMERSION WELLS AND COMPRESSION FITTINGS ® U.S. Registered T rademark © 2008 Honeywell International I nc. 68-0040—04 M.S. Rev . 0 ...

Fabbricante Honeywell Categoria Plumbing Product

I documenti che otteniamo dal fabbricante del dispositivoHoneywell 121371B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Honeywell
- manuali per l’uso 121371B
- schede prodotto Honeywell
- opuscoli
- o etichette energetiche Honeywell 121371B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Honeywell 121371B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Honeywell 121371B, manuali di manutenzione, brevi manuali o manuali utente Honeywell 121371B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Honeywell 121371B.

Manuali per l’uso simili

Manuale completo del dispositivo Honeywell 121371B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Honeywell 121371B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Honeywell 121371B.

Il manuale per l’uso completo Honeywell, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Honeywell 121371B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Honeywell 121371B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Honeywell 121371B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Honeywell 121371B - che ci dovrebbe aiutare nei primi passi durante l'uso Honeywell 121371B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Honeywell 121371B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Honeywell 121371B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Honeywell 121371B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Honeywell 121371B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Honeywell 121371B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)