    14” HEA VY DUTY CUT -OFF SA W Model 91938 SET UP AND OPERA TING INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2004 by Harbor Freight T ools ® . All rights reserved. No portion of this manual or any artw ...

  • Chicago Electric 91938 - page 2

    Page 2 For technical questions, please call 1-800-444-3353. SKU 91938 CONTENTS IMPORT ANT SAFETY INFORMA TION ................................. 3 GENERAL T OOL SAFETY W ARNINGS . 3 GROUNDING INSTRUCTIONS .......... 5 1 10-120 V~ GROUNDED TOOLS: TOOLS WITH THREE PRONG PLUGS ....................... 5 CUT -OFF SA W SAFETY W ARNINGS .... 5 SPECIFICA TI ...

  • Chicago Electric 91938 - page 3

    Page 3 For technical questions, please call 1-800-444-3353. SKU 91938 SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product ha ...

  • Chicago Electric 91938 - page 4

    Page 4 For technical questions, please call 1-800-444-3353. SKU 91938 USE RIGHT TOOL. Don’t force tool or 8. attachment to do a job for which it was not designed. RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS (120 VOL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25’ 50’ 100’ 150’ 0 – 6 18 16 16 14 6.1 – 10 18 16 14 ...

  • Chicago Electric 91938 - page 5

    Page 5 For technical questions, please call 1-800-444-3353. SKU 91938 GROUNDING INSTRUCTIONS TO PREVENT ELECTRIC SHOCK AND DEA TH FROM INCORRECT GROUNDING WIRE CONNECTION READ AND FOLLOW THESE INSTRUCTIONS: 1 10-120 V~ Grounded T ools: T ools with Three Prong Plugs In the event of a malfunction or 1. breakdown, grounding provides a path of least re ...

  • Chicago Electric 91938 - page 6

    Page 6 For technical questions, please call 1-800-444-3353. SKU 91938 The Swing Guard (53) should be 2. retracted manually only for special cuts such as “Pocket Cuts) and “Compound Cuts.” Raise the Swing Guard (53) only enough to begin the cut. As soon as the Cut-Off Wheel enters the material, the Swing Guard (53) must be released. For all ot ...

  • Chicago Electric 91938 - page 7

    Page 7 For technical questions, please call 1-800-444-3353. SKU 91938 pacemaker interference or pacemaker failure. W ARNING: Some dust created by power 23. sanding, sawing, grinding, drilling, and other construction activities, contains chemicals known [to the State of California] to cause cancer , birth defects or other reproductive harm. Some exa ...

  • Chicago Electric 91938 - page 8

    Page 8 For technical questions, please call 1-800-444-3353. SKU 91938 SPECIFICA TIONS Electrical Input 120 V~ / 60 Hz / 2 HP Motor No Load Speed 3500 RPM Max. Accessory Diameter 14” Recommended Cut-Off Wheel T ypes 14” Cut-Off Wheel for Metal (SKU 44814, included) 14” Cut-Off Wheel for Masonry (SKU 44815) Cutting Capacity 4-1/4” Quick Relea ...

  • Chicago Electric 91938 - page 9

    Page 9 For technical questions, please call 1-800-444-3353. SKU 91938 OPERA TING INSTRUCTIONS Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. T ool Set Up TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: Release the T rig ...

  • Chicago Electric 91938 - page 10

    Page 10 For technical questions, please call 1-800-444-3353. SKU 91938 LOOSEN THE BOL T (1 12) 7. and make sure that the Swing Guard (53) moves freely back into place before operation. Depth Adjustment FIGURE 3 Lock Ball (25) Depth Adjustment Bolt (16) T o adjust the depth, turn the Depth Adjustment Bolt (16) shown in FIGURE 3 . W ork Piece and Wor ...

  • Chicago Electric 91938 - page 11

    Page 1 1 For technical questions, please call 1-800-444-3353. SKU 91938 FIGURE 5 Bolts (41 & 44) Angle Scale (35) Upper T wo Screw Holes b. T o cut at various angles (up to 45 degrees), adjust the Angle Scale (35) by loosening the two Bolts (41 & 44) as shown in FIGURE 5 . Adjust the Angle Scale to the desired setting and then tighten the B ...

  • Chicago Electric 91938 - page 12

    Page 12 For technical questions, please call 1-800-444-3353. SKU 91938 MAINTENANCE AND SER VICING  Proceduresnotspecically explained in this manual must beperformedonlybyaqualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: Release the T rigger , unplug the tool from its electrical outlet a ...

  • Chicago Electric 91938 - page 13

    Page 13 For technical questions, please call 1-800-444-3353. SKU 91938 T roubleshooting Problem Possible Causes Likely Solutions T ool will not start. Cord not connected. 1. No power at outlet. 2. T ool’s thermal reset breaker 3. tripped (if equipped). Internal damage or wear . 4. (Carbon brushes or switch, for example.) Check that cord is plugge ...

  • Chicago Electric 91938 - page 14

    Page 14 For technical questions, please call 1-800-444-3353. SKU 91938 Part Description 1 Bolt M6x14 2 Lock Nut 3 Dust Cover 4 Bolt M5x12 5 Lock Nut M6 6 Nut M10 7 Nut M10 8 Binding Ring 9 W asher 10 Nut M8 11 Bolt 4-M6x24 12 Rubber Foot 13 Base 14 Bracket 15 Nut M8 16 Depth Adjustment Bolt 17 Screw 18 Lock Nut M6 19 Bolt 2-M5x10 21 Lock Down Pin 2 ...

  • Chicago Electric 91938 - page 15

    Page 15 For technical questions, please call 1-800-444-3353. SKU 91938 ASSEMBL Y DIAGRAM Hex Key (1 1 1a) - not shown. REV 10a, 10b 1 12 ...

  • Chicago Electric 91938 - page 16

    Page 16 For technical questions, please call 1-800-444-3353. SKU 91938 LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days fro ...

Fabbricante Chicago Electric Categoria Saw

I documenti che otteniamo dal fabbricante del dispositivoChicago Electric 91938 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Chicago Electric
- manuali per l’uso 91938
- schede prodotto Chicago Electric
- opuscoli
- o etichette energetiche Chicago Electric 91938
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Chicago Electric 91938.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Chicago Electric 91938, manuali di manutenzione, brevi manuali o manuali utente Chicago Electric 91938. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Chicago Electric 91938.

Manuali per l’uso simili

Manuale completo del dispositivo Chicago Electric 91938, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Chicago Electric 91938 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Chicago Electric 91938.

Il manuale per l’uso completo Chicago Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Chicago Electric 91938 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Chicago Electric 91938, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Chicago Electric 91938 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Chicago Electric 91938 - che ci dovrebbe aiutare nei primi passi durante l'uso Chicago Electric 91938
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Chicago Electric 91938
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Chicago Electric 91938 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Chicago Electric 91938?

Utilizza il modulo sottostante

Se non hai risolto il problema con Chicago Electric 91938 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Chicago Electric 91938 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)