Manuale per l’uso U-Line CLR60

36 pagine 0.31 mb
Scarica

Vai alla pagina of 36

Summary
  • U-Line CLR60 - page 1

    R R R C P .O. Box 245040 Milwaukee, WI 53224-9540 Phone 414.354.0300 F AX 414.354.7905 CLR60 CLEAR ICE MACHINE Printed in U.S.A. P/N 41952 User’ User’ s Manual s Manual ...

  • U-Line CLR60 - page 2

    U-LINE CORPORA TION LIMITED W ARRANTY U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase; and warrants the sealed system (consisting of the compressor , the condenser , the evaporator , the hot gas bypass valve, the dryer and the connecting tubing) ...

  • U-Line CLR60 - page 3

    INTRODUCTION Congratulations on your purchase of a U-Line CLR 60 Ice Maker . A pio- neer in the field for more than 35 years, U-Line is the world’ s number one manufacturer of built-in, under-counter ice making and specialty refrigeration products. U-Line dedicates 100% of its research and development to these products. The result: U-Line leads t ...

  • U-Line CLR60 - page 4

    If you do not return your W arranty Registration Card, U-Line will use the date of sale to the U-Line distributor as the first date of warranty for your new ice maker . Please also record the purchase date or your U-Line unit and your dealer’ s name, address and telephone number . Model Number: ________________________________________ Serial Numb ...

  • U-Line CLR60 - page 5

    SAFETY PRECAUTIONS Do not attempt to install or operate your unit until you have read the safety precautions in this section. Safety items throughout this manu- al are labeled with W arning or Caution. Wa r ning means that failure to follow this safety statement may result in extensive product damage, serious personal injury or death. Caution means ...

  • U-Line CLR60 - page 6

    4 User’s Manual • Never install the unit behind closed doors. Be sure front grille is free of obstruction. Obstr ucting free air flow can cause the unit to malfunction, and may void the warran- ty . • Use only genuine U-Line replacement parts. Imitation parts can reduce ice rate, cause water to over flow from the ice maker , cause flooding, d ...

  • U-Line CLR60 - page 7

    5 DRAIN INST ALLATION PLEASE READ all instructions completely before attempting to install or operate the unit. All Ice Makers require a con- nection to the water supply and improper hook-up can r esult in substantial property damage! All water and drain connections MUST BE made by a licensed/qualified plumb- ing contractor . Failure to follow reco ...

  • U-Line CLR60 - page 8

    To prevent accidental electr ocution, make certain that the floor surfaces surr ounding the unit are dry whenever power is removed from, or applied to the unit. 1. Make cer tain the unit is not plugged into an electrical outlet. 2. Using a screwdriver , carefully push the power cord grommet through the hole in the back panel. 3. Using a screwdriver ...

  • U-Line CLR60 - page 9

    5. Place a suitable container beneath the pump’ s discharge tube. (The bucket must be able to hold a minimum of one gallon.) Back panel serves as a guard. DO NOT put your hands inside the ice maker cabinet or attempt to touch any com- ponents except the discharge tube during testing. Failure to follow this warning could result in serious personal ...

  • U-Line CLR60 - page 10

    • Overall maximum outside dimensions of 8-3/4" wide x 5-3/4" deep x 7-3/4" high. • Minimum flow rate of 15 gallons per hour at 10 feet of lift. • It must have a sealed sump which does not allow water leakage in the case of a power outage, restricted drain or pump failure. • It must have a check valve in the discharge line to ...

  • U-Line CLR60 - page 11

    6. Install a 1/4 inch copper water line (not supplied with unit) from the nearest COLD water pipe. When connecting the water supply , follow these guidelines: • Review the local plumbing codes before you install the unit. • In most instances, the cold water supply will come from the basement through a hole in the floor . • The water pressure ...

  • U-Line CLR60 - page 12

    • Install a shut-off valve in the 1/4 inch supply line. • Connect sufficient tubing to the unit to allow the unit to be moved for cleaning and ser- vicing. However , make cer- tain that the tubing is not pinched or damaged during installation. • U-Line specifies the use of copper tubing for installation. Position the unit to allow free air fl ...

  • U-Line CLR60 - page 13

    4. Locate the compression fit- ting and ferrule packed in the unit. Slide the compression fitting and ferrule over the 1/4 inch water supply line. Do not use thread sealing compound or tape. Using two wrenches, tighten the compression fitting on the supply line (see Figure 6). Figure 6 5. Carefully bend the water sup- ply line into position and con ...

  • U-Line CLR60 - page 14

    NOTE After completing the installation, turn on the water and r echeck water and drain connection for leaks. Apply addi- tional tightening if needed. Do NOT use thread sealing com- pound or tape. NOTE Route the water supply line through the clip on the sidewall of the unit in such a way as to prevent the line from com- ing in contact with any inter ...

  • U-Line CLR60 - page 15

    3. Check the levelness after each adjustment and repeat the previous steps until the unit is level. GRILLE INST ALLATION 1. With a standard blade screwdriver (or 1/4" nutdriver), remove the screw needed to attach the grille (see Figure 12). 2. Carefully remove the grille, which is packaged inside of the unit. A small screw hole is located towa ...

  • U-Line CLR60 - page 16

    3. Place the two hook-hinges (locat- ed on the rear bottom side of the grille) on the front lip of the unit base. Swing the grille up into posi- tion, aligning the grille and cabinet screw holes (see Figure 13). 4. Inser t the screw , being careful not to over tighten. 14 User’s Manual UL109 UL207 Figure 13 Figure 15 REVERSING THE DOOR Depending ...

  • U-Line CLR60 - page 17

    5. Install hinge on opposite side, bottom of cabinet (see Figure 18). Replace nut on back side where installed. Align hinge outer edge with cabinet before tightening screws. 3. Lift the door off the bottom hinge. 4. Remove bottom hinge from cabinet (2 screws) (see Figure 16). Remove screws on opposite side of cabinet (see Figure 17). Note that ther ...

  • U-Line CLR60 - page 18

    8. Remove pivot screw from top hinge, inver t screw and reinstall pivot screw in top hinge (see Figure 20). 9. Remove three plastic plugs in hinge holes, top of cabinet, opposite side. Be careful not to scratch cabinet (see Figure 21). 10. Inver t and install upper hinge on door . 16 User’s Manual HINGE RIGHT SIDE DOOR SWING LEFT SIDE DOOR SWING ...

  • U-Line CLR60 - page 19

    13. Replace three plastic plugs removed in step 8 into holes on top of unit. Replace screws in holes in bottom of unit, opposite side. 14. Reinspect door seal and alignment. Adjust if needed. 15. Reinstall grille (1 screw). ALIGNING THE DOOR For proper door alignment: 1. Loosen top and bottom hinge screws (see Figure 15). 2. Align door squarely wit ...

  • U-Line CLR60 - page 20

    Figure 23 UL131 Custom Door Panel Dimensions Model A B CLR 60 28-5/32" 13-15/16" CLR 60SS 29-13/32" 13-15/16" SS - Stainless steel units Install the inser t as follows: Insert edges may be SHARP! Use care when installing. ! WARNING ! 18 User’s Manual B A Figure 24 UL132 1. Remove top hinge screw pin (large Phillips head, see F ...

  • U-Line CLR60 - page 21

    7. Holding door gasket out of the way , replace handle on door making sure it is seated prop- erly on inser t and that screw holes line up. 8. Install two small screws removed in step 3. Be careful no to over tighten these screws. This could strip the plastic. 9. Star ting at the center and working outward, push door gasket into place on door . 10. ...

  • U-Line CLR60 - page 22

    INITIAL ST AR T-UP Once installation and leveling is complete, the unit is ready for initial star t-up and operation. 1. Plug the appliance cord into a 115V polarized and grounded elec- trical outlet. 2. Open the water supply valve in the main water source. 3. Put the cycle selector switch in the ICE position (press the switch to the right). The wa ...

  • U-Line CLR60 - page 23

    21 UL227 C L N O F F I C E Figure 27 NORMAL OPERATION The ice maker is designed to make clear ice from most water sources on a consistent basis. W ater is constantly circulated over the evapo- rator assembly . As the water freezes, gravity causes any sediment to drop into the water trough and not become imbedded in the ice. This gives a clearer ice ...

  • U-Line CLR60 - page 24

    ADJUSTING ICE THICKNESS The ice thickness control is set to automatically maintain an ice bridge of 0.16-0.32 cm (1/16- 1/8 inch) thick. A dimple in each cube is normal (see Figure 28). If an adjustment is needed, per- form the following steps: Do not touch electrical wires. Disconnect power to the ice maker before making any ice thickness adjustme ...

  • U-Line CLR60 - page 25

    NOTE Ice thickness adjustment dial should be turned only one increment at a time. Allow unit to stabilize for 24 hours before making further adjustments. 4. T urn ice thickness adjustment dial clockwise for a thicker ice bridge or counterclockwise for a thinner ice bridge. 5. Reinstall front access panel. 6. Reconnect power . CARE AND CLEANING EXTE ...

  • U-Line CLR60 - page 26

    24 User’s Manual UL005A Figure 30 UL204C Figure 31 INLET SCREEN CLEANING The solenoid valve inlet screen must be cleaned at least once each year as follows: 1. Shut of f the water at the water supply valve. 2. Remove front access panel to expose water solenoid valve. 3. Remove the entire hose con- nector from the solenoid valve. 4. Use a tooth br ...

  • U-Line CLR60 - page 27

    Use only U-Line Ice Machine Cleaner (part number 41978). It is a violation of Federal law to use this solution in a man- ner inconsistent with its labeling. Use of any other cleaner can ruin the finish of the evaporator and will void the war- ranty . Read and understand all labels printed on the pack- age before use. Ice machine cleaner is used to ...

  • U-Line CLR60 - page 28

    7. When water begins to flow over the evaporator (approxi- mately 3 minutes), add one package of U-Line Ice Machine cleaner to the water reser voir . 8. Reinstall inside front cover . 9. When the self-cleaning process stops (approximate- ly 45 minutes) it may be desirable to clean the stor- age bin at this time (see INTERIOR STORAGE BIN CLEANING ). ...

  • U-Line CLR60 - page 29

    STORAGE, V ACATION AND MOVING If the unit is to be stored, moved or not used for extended periods, it will be necessar y to drain the system of water . Electrical Shock Hazard. Disconnect power before servicing. Befor e operating replace all panels. Failure to do so can result in death or electrical shock. 1. Disconnect power from the unit. 2. Remo ...

  • U-Line CLR60 - page 30

    TROUBLESHOOTING BEFORE CALLING FOR SERVICE If the unit appears to be malfunctioning, read through NORMAL OPER- A TION first. If the problem persists, check the TROUBLESHOOTING GUIDE. Locate the problem in the guide and refer to the cause and its remedy before calling for ser vice. The problem could be something ver y simple which can be solved with ...

  • U-Line CLR60 - page 31

    Problem Possible Cause Remedy Unit runs but Inadequate airflow at Remove items blocking produces ver y the front of the unit airflow little ice Ice thickness Adjust ice thickness. (continued) adjustment dial See ADJUSTING ICE improperly set THICKNESS Ice is slow to Ice-making system Run unit through release or does is dir ty automatic clean cycle. ...

  • U-Line CLR60 - page 32

    Problem Possible Cause Remedy W ater leaking Supply line leaking Check to see that water from under the inlet line is attached to unit inlet valve properly . See CONNECTING THE WA TER SUPPL Y Fill tube leaking Check connection at water valve outlet Bin drain leaking Check integrity of bin drain hose and clamp Ice storage bin Obstructed drain Check ...

  • U-Line CLR60 - page 33

    31 Notes ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ _________________ ...

  • U-Line CLR60 - page 34

    Notes ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ____________________ ...

  • U-Line CLR60 - page 35

    ...

  • U-Line CLR60 - page 36

    R R R C P .O. Box 245040 Milwaukee, WI 53224-9540 Phone 414.354.0300 F AX 414.354.7905 CLR60 CLEAR ICE MACHINE Printed in U.S.A. P/N 41952 User’ User’ s Manual s Manual ...

Fabbricante U-Line Categoria Ice Maker

I documenti che otteniamo dal fabbricante del dispositivoU-Line CLR60 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici U-Line
- manuali per l’uso CLR60
- schede prodotto U-Line
- opuscoli
- o etichette energetiche U-Line CLR60
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso U-Line CLR60.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione U-Line CLR60, manuali di manutenzione, brevi manuali o manuali utente U-Line CLR60. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto U-Line CLR60.

Manuali per l’uso simili

Manuale completo del dispositivo U-Line CLR60, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare U-Line CLR60 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti U-Line CLR60.

Il manuale per l’uso completo U-Line, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale U-Line CLR60 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice U-Line CLR60, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per U-Line CLR60 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo U-Line CLR60 - che ci dovrebbe aiutare nei primi passi durante l'uso U-Line CLR60
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del U-Line CLR60
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio U-Line CLR60 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su U-Line CLR60?

Utilizza il modulo sottostante

Se non hai risolto il problema con U-Line CLR60 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con U-Line CLR60 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)