Manuale per l’uso Heat Controller DMC24DB-1

29 pagine 3.64 mb
Scarica

Vai alla pagina of 29

Summary
  • Heat Controller DMC24DB-1 - page 1

    DMC24DB-1, DMH24DB-1 DMC36TB-1, DMH36TB-1 ...

  • Heat Controller DMC24DB-1 - page 2

    2 Room Air Conditioner Room Air Conditioner Installation Manual T ABLE OF CONTENTS Installation Parts Pro vided ......................................... 3 Safety Precautions ...................................................... 4 Installation of Indoor , Outdoor Unit ........................... 9 Select the best location ......................... ...

  • Heat Controller DMC24DB-1 - page 3

    Installation Manual 3 Installation P ar ts Provided Installation P ar ts Pr ovided Type "A" screws and plastic anchors Type "B" screws Holder Remote Control Installation plate Standard Type more than 70cm (27.6 inch) more than 30cm (11.8 inch) more than 30cm (11.8 inch) Air Outlet Air Intake (side, rear) Connection pipe Drain ho ...

  • Heat Controller DMC24DB-1 - page 4

    4 Room Air Conditioner Safety Precautions Safety Precautions T o pre vent the injury of the user or other people and proper ty damage, the follo wing instructions must be f ollowed. ■ Incorrect operation due to ignoring instruction will cause har m or damage. The seriousness is classified by the f ollowing indications. ■ The meanings of the sym ...

  • Heat Controller DMC24DB-1 - page 5

    Installation Manual 5 Safety Precautions ■ Operation Be sure the installation area does not deteriorate with age. • If the base collapses, the air conditioner could fall with it, causing proper ty damage, product failure , and personal injury . Install the indoor unit on the wall where the height from the floor s more than 8ft(2.4m) • There a ...

  • Heat Controller DMC24DB-1 - page 6

    6 Room Air Conditioner Saf ety Precautions Stop operation and close an y window in storm or hurricane. before the hurricane arrives. • There is risk of proper ty damage, failure of product, or electric shock. Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter , if the unit is so equipped.) • Ther ...

  • Heat Controller DMC24DB-1 - page 7

    Installation Manual 7 ■ Installation ■ Operation Do not direct airflow at room occupants. • This could damage your health. Do not use the product f or special purposes, suc h as preserving foods, works of art, etc. It is a consumer air conditioner , not a precision refrigeration system. • There is risk of damage or loss of proper ty . Do no ...

  • Heat Controller DMC24DB-1 - page 8

    8 Room Air Conditioner Saf ety Precautions Use a soft cloth to c lean. Do not use harsh detergents, solvents, etc. • There is risk of fire, electric shock or damage to the plastic par ts of the product. Do not touch the metal parts of the product when removing the air filter . They are very sharp! • There is risk of personal injur y . Do not st ...

  • Heat Controller DMC24DB-1 - page 9

    Installation of Indoor , Outdoor Unit Installation Manual 9 Installation of Indoor , Outdoor Unit Read completely , then follow step b y step. Indoor unit 1. Do not ha ve an y heat or steam near the unit. 2. Select a place where there are no obstacles in front of the unit. 3. Mak e sure that condensation drainage can be conv eniently routed aw a y ...

  • Heat Controller DMC24DB-1 - page 10

    10 Room Air Conditioner Installation of Indoor , Outdoor Unit Multi Piping T ype Piping length and elev ation 24k 30m(100ft) 15m(50ft) 3m(10ft) 7.5m(25ft) 7.5m(25ft) 36k 45m(150ft) 15m(50ft) 3m(10ft) 7.5m(25ft) 7.5m(25ft) Capacity(Btu/h) Max total length of all pipes (A+B/A+B+C) Max length of each pipe (A/B/C) Min length of each pipe (A/B/C) Max El ...

  • Heat Controller DMC24DB-1 - page 11

    Installation of Indoor , Outdoor Unit Installation Manual 11 The wall y ou select should be strong and solid enough to pre vent vibration 1. Mount the installation plate on the w all with type "A" screws . If mounting the unit on a concrete wall, use anchor bolts . • Mount the installation plate horizontally b y aligning the centerline ...

  • Heat Controller DMC24DB-1 - page 12

    12 Room Air Conditioner Flaring W or k and Connection of Piping Flaring W ork and Connection of Piping Flaring w ork Main cause f or gas leakage is due to defect in flaring work. Carry out correct flaring wor k in the f ollowing procedure. Cut the pipes and the cable. 1. Use the piping kit accessory or the pipes purchased locally . 2. Measure the d ...

  • Heat Controller DMC24DB-1 - page 13

    Flaring W or k and Connection of Piping Installation Manual 13 Check 1. Compare the flared w ork with the figure by . 2. If a flared section is def ective, cut it off and do flaring work again. Indoor 1. Prepare the indoor unit's piping and drain hose f or installation through the wall. 2. Remo ve the plastic tubing retainer(see the illustrati ...

  • Heat Controller DMC24DB-1 - page 14

    14 Room Air Conditioner Flaring W or k and Connection of Piping 4. Indoor unit installation Hook the indoor unit onto the upper por tion of the installation plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by mo ving it ...

  • Heat Controller DMC24DB-1 - page 15

    Flaring W or k and Connection of Piping Installation Manual 15 1. Route the indoor tubing and the dr ain hose to the required piping hole position. 2. Insert the piping, drain hose, and the connecting cable into the piping hole . 3. Inser t the connecting cable into the indoor unit. • Don't connect the cable to the indoor unit. • Make a sm ...

  • Heat Controller DMC24DB-1 - page 16

    16 Room Air Conditioner Flaring W or k and Connection of Piping Wrap the insulation material around the connecting portion. 1. Ov erlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there ma y be no gap . 2. Wrap the area which accommodates the rear piping housing s ...

  • Heat Controller DMC24DB-1 - page 17

    Flaring W or k and Connection of Piping Installation Manual 17 Installation Inf or mation. F or left piping. F ollow the instruction below . Good case • Press on the upper side of clamp and unf old the tubing to downw ard slowly . Bad case • F ollowing bending type from right to left ma y cause damage to the tubing. ...

  • Heat Controller DMC24DB-1 - page 18

    18 Room Air Conditioner Flaring W or k and Connection of Piping Outdoor Align the center of the pipings and sufficiently tighten the flare nut b y hand. Finally , tighten the flare nut with torque wrench until the wrench clicks . • When tightening the flare nut with torque wrench, ensure the direction f or tightening f ollows the arrow on the wre ...

  • Heat Controller DMC24DB-1 - page 19

    Connecting the Cable between Indoor Unit and Outdoor Unit Installation Manual 19 Connecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the indoor unit b y connecting the wires to the terminals on the control board individuall y according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit ...

  • Heat Controller DMC24DB-1 - page 20

    20 Room Air Conditioner Connecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the Outdoor unit. 1. Remo ve the co ver control from the unit b y loosening the screw . Connect the wires to the terminals on the control board individually as the f ollowing. 2. Secure the cab le into the control board with the strain relief clam ...

  • Heat Controller DMC24DB-1 - page 21

    Connecting the Cable between Indoor Unit and Outdoor Unit Installation Manual 21 (1) Remov e two-caps on the conduit panel. (2) Make a hole appropriate f or the passage of connection cable through on cap b y tool. (f or low voltage line) (3) P ass the connecting cable through the hole . (4) Properly connect the cable on the terminal block. (5) Fix ...

  • Heat Controller DMC24DB-1 - page 22

    22 Room Air Conditioner Connecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the indoor unit CA UTION! Provide a cir cuit breaker between the power sour ce and the outdoor unit as shown belo w . Size breaker per the Maximum Fuse or Circuit Breaker (MOC) rating on the unit rating plate. Air Conditioner Circuit Breaker Use a ...

  • Heat Controller DMC24DB-1 - page 23

    Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting Installation Manual 23 Chec king the Drainage, Forming the Pipings and Long Pipe Setting Chec king the drainage T o chec k the drainage. 1. P our a glass of water on the e v aporator . 2. Ensure the w ater flows through the drain hose of the indoor unit without any leakage and goes ...

  • Heat Controller DMC24DB-1 - page 24

    24 Room Air Conditioner Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting Forming the piping Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vin yl tape. • If y ou want to connect an additional drain hose, the end of the drain outlet should be routed ...

  • Heat Controller DMC24DB-1 - page 25

    Air Purging and Evacuation Installation Manual 25 Air Pur ging and Ev acuation Air and moisture remaining in the refrigerant system hav e undesirab le effects as indicated belo w . 1. Pressure in the system rises. 2. Oper ating current rises. 3. Cooling(or heating) efficiency drops . 4. Moisture in the refrigerant circuit ma y freeze and bloc k cap ...

  • Heat Controller DMC24DB-1 - page 26

    26 Room Air Conditioner Air Purging and Evacuation 1. Connect the charge hose end described in the preceding steps to the vacuum pump to e vacuate the tubing and indoor unit. Confirm the "Lo" knob of the manifold v alve is open. Then, r un the vacuum pump . The operation time f or e vacuation v aries with tubing length and capacity of the ...

  • Heat Controller DMC24DB-1 - page 27

    Charging Installation Manual 27 Char ging ■ Each outdoor unit is f actor y charged (nameplate charge) for the e vaporator as well as a 7.5m(25ft) line set f or each indoor line. Any time total line set is used either shorter or longer then the nominal 22.5m(75ft: for tri-zone) line set length the refrigerant charge has to be adjusted. ■ Whether ...

  • Heat Controller DMC24DB-1 - page 28

    28 Room Air Conditioner T est Running 1. Chec k that all tubing and wiring hav e been properly connected. 2. Chec k that the gas and liquid side ser vice valv es are fully open. Prepare remote control Remov e the batter y cov er by pulling it according to the arrow direction. Inser t new batteries making sure that the (+) and ( – ) of batter y ar ...

  • Heat Controller DMC24DB-1 - page 29

    P/No . : 3828A22013Z Specifications and performance data subject to change without notice. HEA T CONTROLLER, INC. 1900 WELL WOR TH A VENUE • JACKSON, MICHIGAN 49203 THE QU ALITY LEADER IN CONDITIONING AIR ...

Fabbricante Heat Controller Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoHeat Controller DMC24DB-1 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Heat Controller
- manuali per l’uso DMC24DB-1
- schede prodotto Heat Controller
- opuscoli
- o etichette energetiche Heat Controller DMC24DB-1
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Heat Controller DMC24DB-1.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Heat Controller DMC24DB-1, manuali di manutenzione, brevi manuali o manuali utente Heat Controller DMC24DB-1. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Heat Controller DMC24DB-1.

Manuale completo del dispositivo Heat Controller DMC24DB-1, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Heat Controller DMC24DB-1 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Heat Controller DMC24DB-1.

Il manuale per l’uso completo Heat Controller, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Heat Controller DMC24DB-1 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Heat Controller DMC24DB-1, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Heat Controller DMC24DB-1 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Heat Controller DMC24DB-1 - che ci dovrebbe aiutare nei primi passi durante l'uso Heat Controller DMC24DB-1
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Heat Controller DMC24DB-1
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Heat Controller DMC24DB-1 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Heat Controller DMC24DB-1?

Utilizza il modulo sottostante

Se non hai risolto il problema con Heat Controller DMC24DB-1 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Heat Controller DMC24DB-1 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)