    TECHNIC AL GUIDE A DD - ON COILS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T PUMPS MODELS: GHD, GFD, GF A, GNA, GUA & GHA 600 - 2000 CF M 2 - 5 TO N COILS Due to continuous p roduct imp rovement, spe cifications a re subject to change without notice. V isit us on th e web at www .york.c om for the mos t up-to-date tech nica l information. A ...

  • York GFD - page 2

    036-2114 5-003 Rev. A (0403) 2 Unitary Produ cts Grou p COOLING CAP AC ITY - Coil Only * MODEL RA TED CFM ENTERING AIR ° F (WET BULB) MBH @ EVAPORATOR T EMPERATURE AND CORRESPONDING PRES SURE ° F / P SIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 UPFLOW " A" TYPE G1F A024S14(T) G1UA024S14 675 72 35.6 32.5 29.0 25.2 67 32.9 29.7 26.3 22.7 6 ...

  • York GFD - page 3

    036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 3 Notes: • G2FD coils available with a factory installed horizontal drain pan option (H). • G2FD061H24 is only available with a factory m ounted horizontal pan. (T) indicates mod els with factory installed th ermal expansion valve. COOLING CAP ACITY - COIL ONL Y * Model Coil Rated CFM Enterin ...

  • York GFD - page 4

    036-2114 5-003 Rev. A (0403) 4 Unitary Produ cts Grou p NOTE: Do not exceed minimum/maxim um CFM limits shown under Air Flow Data. APPLICA T ION LIMIT A TIO NS These un its m ust be ins talled in accordanc e with all n ational and lo cal saf ety code s. Air flow mu st be within the m inimum an d maximum lim its approve d for elec tric hea t, evapor ...

  • York GFD - page 5

    036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 5 ST A TIC PRESSURE VS. AIRFLOW (BASED ON WE T COIL) (T) Indicates models with factory installed thermal expansion valve. (T) Indicates models with factory installed thermal expansi on valve. MODEL AIRFLOW WET C OIL UPFLOW C ASED "A" T YPE G1F A024S14(T) G1UA024S14 600 0.12 800 0.21 100 ...

  • York GFD - page 6

    036-2114 5-003 Rev. A (0403) 6 Unitary Produ cts Grou p PHYSICAL DA T A MODEL APPLICA TION REFRIG . CONN. TYPES STD. ORIFICE SIZE F ACE AREA (SQ . FT .) ROWS DEEP FIN PER IN. COIL SIZE TUBE GEOMETRY TUBE DIA. FIN TYPE EXP ANSION DEVICE OPE RA TIN G WEIGHT (LBS.) UPFLOW " A" TYPE G1F A024S 14 Cooling / Heat Pump Sweat 59 2.92 2 14 (2) 12 x ...

  • York GFD - page 7

    036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 7 Note: • G2FD coils available with a factory installed horizontal drain pan option (H). • G2FD061H24 is only available with a factory m ounted horizontal pan. • G1HA Models with the (T) option f eature a factory installed t hermal expansion valve. FULL CAS ED "A" TYPE MUL TI-POS ...

  • York GFD - page 8

    036-2114 5-003 Rev. A (0403) 8 Unitary Produ cts Grou p DIMENSIONS NOTE: (T) indica tes models with fa ctory installed thermal expansion va lve. G1F A UPFLOW CASED COIL C 20-7/8 22 A B D 20-3/16 MODE L DIMENSIONS — INCHES REFRIGERANT CONNECTIONS AB C D E F G LINE SI ZE LIQUID V APOR G1F A024S14(T) 14-1/2 16 13-3/8 13-1/2 - - - 3/8 5/8 G1F A 024S1 ...

  • York GFD - page 9

    036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 9 G1UA UPFLOW CASED COIL D 20-3/16 22 A 10 C 20-7/8 B MODE L DIMENSIONS — INCHES REFRIGERANT CONNECTIONS AB C D E F G LINE SI ZE LIQUID V APOR G1UA024S14 14-1/2 14-1/2 13-3/8 13-1/2 - - - 3/8 5/8 G1UA024S17 17-1/2 14 1 6-3/8 16-1/2 - - - 3/8 5/8 G1UA030S14 14-1/2 16-5/8 13-3/8 13-1/2 - - - 3/8 ...

  • York GFD - page 10

    036-2114 5-003 Rev. A (0403) 10 Unitary Produ cts Grou p NOTE: (T) indica tes models with fa ctory installed thermal expansion va lve. G1HD HORIZONT AL D UCT COIL 1-3/ 8 7 /8 1-7 /8 3-3/ 4 1 -3 /8 2-5 /8 B A D C 5 - 5 / 8 1-3/ 4 OUTLET S AME SIZE A S IN LET (ALL F LANGES 3 / 4" T HICK ) 4 -1 /8 LIQ UI D CONN. VA P O R CONN. 3/ 4 MPT SECONDARY ...

  • York GFD - page 11

    036-21145 -003 Rev. A (0403) Unitary Pro ducts Group 11 NOTE: G2FD coi ls available with a factory in stalled horizo ntal drai n pan optio n (H). G2FD061H24 is only available with a factory m ounted horizontal pan (T) indicates mod els with factory installed th ermal expansion valve. Only a vailable on coils with factory installed horizontal drain ...

  • York GFD - page 12

    Subject to change without notice. Printed in U.S.A. 036-21145-003 Rev. A (0403) Copyright © by York International Corp. 2003. All rights reserved. Supersedes: 036-21145-002 Rev. a (0203) Uni tary 5005 N orm an Product s Y ork OK Group Drive 73069 G1NA COIL MODE LS DIMENSIONS — INCHES REFRIGERANT CONNECTIONS A BCD E F G QUICK-CONNECT LINE SIZE LI ...

Fabbricante York Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoYork GFD possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici York
- manuali per l’uso GFD
- schede prodotto York
- opuscoli
- o etichette energetiche York GFD
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso York GFD.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione York GFD, manuali di manutenzione, brevi manuali o manuali utente York GFD. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto York GFD.

Manuali per l’uso simili

Manuale completo del dispositivo York GFD, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare York GFD dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti York GFD.

Il manuale per l’uso completo York, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale York GFD - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice York GFD, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per York GFD che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo York GFD - che ci dovrebbe aiutare nei primi passi durante l'uso York GFD
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del York GFD
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio York GFD in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su York GFD?

Utilizza il modulo sottostante

Se non hai risolto il problema con York GFD con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con York GFD è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)