Summary
  • HP ProLiant BL685c G5 - page 1

    Performance characterization of HP ProLiant BL685c G5 with Quad-Core AMD Optero n processors (2.3 GHz) in a 64-bit HP Server Based Computing environment Executive summary ............................................................................................................................... 3 Audience ........................................ ...

  • HP ProLiant BL685c G5 - page 2

    Appendix C – SBC solution sizing ....................................................................................................... 21 Online sizer tool ............................................................................................................................ 21 For more information ......................................... ...

  • HP ProLiant BL685c G5 - page 3

    Executive summary Important: This document describes a perfor mance characterization performed utilizing the HP 64-bit test harness, which incorporates a Microsoft® Office 2003 workload. Test results cannot be compared directly wit h the results of tests performed using the 32-bit Office XP- or Office 2003-based h arness. The HP ProLiant BL685c G5 ...

  • HP ProLiant BL685c G5 - page 4

    Figure 1 . HP ProLiant BL685c G5 server blade AMD Opteron processors The HP ProLiant BL685c G5 server blade supports up to four Quad-Core AMD Opteron 8300 Series processors. This native quad-core proc essor delivers the following benefits: • Outstanding performance The Quad-Core Opteron processor is designed fo r optimal multi-threaded applicatio ...

  • HP ProLiant BL685c G5 - page 5

    • Investment protection By leveraging AMD’s Common Co re Strategy and Same Socket Technology, Quad-Core Opteron processors can minimiz e changes to the custom er’s software and data center infrastructure, protecting IT investments and simplifying management. AMD Dual Dynamic Power Management Dual Dynamic Power Management fu nctionality allows ...

  • HP ProLiant BL685c G5 - page 6

    Test methodology HP continues to upgrade existing HP ProLiant server s and introduce new servers to meet particular business needs. To help customers select th e appropriate server for their particular HP SBC environment, HP publishes this and other perfor mance characterizations so that you can compare individual server performance and scalability ...

  • HP ProLiant BL685c G5 - page 7

    Test tools To facilitate the placement and management of simulated loads on an HP SBC server, HP used Terminal Services Scalability Planning Tools (TSSca ling), a suite of tools developed by Microsoft to help organizations with Microsoft Windows® Se rver 2003 Terminal Server capacity planning. Table 1 describes these tools. Table 1 . Comp onent s ...

  • HP ProLiant BL685c G5 - page 8

    Table 3 outlines the activities performed by each user class uti lizing Office 2003 products. Table 3 . Activities incorporated into the test scripts for each user clas s Activity description Heavy Us er Medium User Light User Access Open a database, apply a filter, search through records, add records, and delete records. X Excel Open, print and sa ...

  • HP ProLiant BL685c G5 - page 9

    Note: When running canary scripts, HP c onsiders user response times to become unacceptable when they increase markedly over a baseline measurement. Test topology Figure 2 illustrates the HP SBC test environment. Figure 2 . The tested environment Note: Test environments such as that sho wn in Figure 2 are available to customers at HP Solution Cente ...

  • HP ProLiant BL685c G5 - page 10

    Configurations Table 4 summarizes the configuration s of servers and clients us ed in the test environment. Table 4 . System configurations Server Configuration 4P HP ProLiant BL685c G5 server blade with: • Opteron Processor Model 8356 (2.3 GHz) – 512 KB L2 cache per core; 2 MB L3 cache • 32 GB RAM • Integrated Smart Array E200i controller ...

  • HP ProLiant BL685c G5 - page 11

    Table 4 . System configurations (continued) Server Configuration Variety of Intel Pentium®-based Compaq Evo workstations (600 MHz – 2.533 GHz), each with: • At least 256 MB of memory • 1024 x 768/16-bit color depth • 100 Mbps NIC Client Windows 2000 Professional or Windows XP HP SBC server summary Table 5 summarizes the configuration o f t ...

  • HP ProLiant BL685c G5 - page 12

    Table 5. System summary for the HP ProLiant BL685c G5 server blad e (continued) Component Description Total physical memory 32,765.62 MB Available physical memory 30.78 GB Total virtual memory 79.06 GB Available virtual memory 78.78 GB Page file space 48.00 GB Page file C:pagefile.sys Performance test results This section outlines the te st result ...

  • HP ProLiant BL685c G5 - page 13

    Perfmon values HP ran a series of performance tests u sing scri pts based on the Heavy, Medium, and Light User profiles. Figure 3 shows the test res ults for Heavy Users. Figure 3 . % Processor Time values for Heavy Users – showing that 301 Heavy Us ers were supported when processor utilization reached 80% Figure 3 shows the optimal number of H e ...

  • HP ProLiant BL685c G5 - page 14

    Canary times Figure 4 shows sample results for the HP ProLiant BL685c G5 server blade running a typical canary script. Individual user response times are shown in blue , with a yellow line depicting average response times. HP analyzed this figure to determine when re sponse times began to increase markedly and consistently over a baseline level, in ...

  • HP ProLiant BL685c G5 - page 15

    Test analysis summary Figure 5 summarizes the optimal numbe rs of users supported by the HP ProLiant BL685c G5 s erver blade. Figure 5 . Optimal numbers of user s supported in the 64-bit test harness For Heavy and Medium Users, HP characterized the scalability of the HP ProLiant BL685c G5 server blade through the numbers of users supported when CPU ...

  • HP ProLiant BL685c G5 - page 16

    Appendix A – HP BladeSystem Out of the box, HP BladeSystem removes constraint s imposed by conventional IT infrastructures, unifying server, storage, networking, power, and mana gement capabilities in a change-ready, energy-thrifty, and cost-effective sy stem. HP BladeSy stem helps customer s of all sizes – from large enterprises to small and m ...

  • HP ProLiant BL685c G5 - page 17

    Management • HP Onboard Administrator provides comp lete control of the infrastruct ure • Interactive HP Insight Display allows easy setup and configuration from the front of the rack • HP Insight Control Environment for HP BladeSystem automates deployment, pr ovisioning, server and performance management, and patch and vulnerabi lity managem ...

  • HP ProLiant BL685c G5 - page 18

    Performance • Up to eight c-Class server blades • Up to three I/O fabrics • Multi-terabit mid-plane to support cu rrent and futu re I/O connection s • N+N and N+1 power redundancy for maximum configuration flexibility • Choice of AC (with support for low-line or high-line power) or DC power supplies Management • HP Onboard Administrator ...

  • HP ProLiant BL685c G5 - page 19

    Appendix B – Using Microsoft Windows Server 2003 x64 Editions Microsoft offers a new generati on of high-performance platfo rms for 64-bit applications with continued support for 32-bit applications and existing deployment and management tools – all on the same platform. These new operating sy stems provid e an evolutionary path to 64-bit techn ...

  • HP ProLiant BL685c G5 - page 20

    More information For more information on the impact of 64-bit Wi ndows Server 2003 x64 Editions in an HP SBC environment, refer to the HP white paper , “Scalability and performance of HP ProLiant s ervers on 64- bit Microsoft Windows Server 2003 in a n HP SBC environment.” To learn about 64-bit computing in an HP SBC environment, refer to the H ...

  • HP ProLiant BL685c G5 - page 21

    Appendix C – SBC solution sizing As with any laboratory benchmark, the performanc e metrics quoted in this performance brief are idealized. In a production environment, these me trics may be impacted by a variety of factors, including the following: • Overhead Agents and services (virus sca nning, backup and restore, provisio ning, security, ma ...

  • HP ProLiant BL685c G5 - page 22

    Figure C-1 . The HP SBC sizer’s welcome s creen Based on information provided by the customer, the sizer can provide a quick, consistent mechanism for identifying the “best-fit” server for a parti cular HP SBC environment and generate a Bill of Materials (BOM) for that server. 22 ...

  • HP ProLiant BL685c G5 - page 23

    For more information HP ProLiant BL685c G5 server blade http://www.hp.com/servers/bl685c HP BladeSystem c-Class server blades http://www.hp.com/servers/cclass HP ActiveAnswers for Serv er Based Computing http://www.hp.com/solutions/activeanswers/hpsbc HP ProLiant Essentials Rapid Deployment Pack (RDP) http://www.hp.com/go/rdp Consolidated HP SBC on ...

Fabbricante HP Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoHP ProLiant BL685c G5 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici HP
- manuali per l’uso ProLiant BL685c G5
- schede prodotto HP
- opuscoli
- o etichette energetiche HP ProLiant BL685c G5
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso HP ProLiant BL685c G5.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione HP ProLiant BL685c G5, manuali di manutenzione, brevi manuali o manuali utente HP ProLiant BL685c G5. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto HP ProLiant BL685c G5.

Manuali per l’uso simili

Manuale completo del dispositivo HP ProLiant BL685c G5, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare HP ProLiant BL685c G5 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti HP ProLiant BL685c G5.

Il manuale per l’uso completo HP, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale HP ProLiant BL685c G5 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice HP ProLiant BL685c G5, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per HP ProLiant BL685c G5 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo HP ProLiant BL685c G5 - che ci dovrebbe aiutare nei primi passi durante l'uso HP ProLiant BL685c G5
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del HP ProLiant BL685c G5
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio HP ProLiant BL685c G5 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su HP ProLiant BL685c G5?

Utilizza il modulo sottostante

Se non hai risolto il problema con HP ProLiant BL685c G5 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con HP ProLiant BL685c G5 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)