    Part No. D20814-004 Oilfr ee Compr essors Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference. Model No. T ype Serial No. ESP AÑOL: PÁGINA 19 FRANÇAISE: P AGE 37 IM ...

  • Porter-Cable CPF6020 - page 2

    2-ENG CAUTION indicates a potentially hazar dous situation which, if not avoided, may result in minor or moderate injury . This manual contains information that is important for you to know and understand. This infor - mation relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS . T o help you recognize this information, we use the sy ...

  • Porter-Cable CPF6020 - page 3

    3-ENG RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONT ACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SP ARK. IF ELECTRICAL SP ARKS FROM COMPRESSOR COME INTO CONT ACT WITH FLAMMABLE V APORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEA TING AND COULD CAUSE FIRE. UNA TT ...

  • Porter-Cable CPF6020 - page 4

    4-ENG RISK FROM FL YING OBJECTS IMPORT ANT SAFETY INSTRUCTIONS (cont’d) THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT , CHIPS, LOOSE P ARTICLES AND SMALL OBJECTS A T HIGH SPEED , RESUL TING IN PROPERTY DAMAGE OR PERSONAL INJUR Y . AL WA YS WEAR ANSI Z87.1 APPROVED SAFETY GLASSES WITH SIDE SHIELDS WHEN ...

  • Porter-Cable CPF6020 - page 5

    5-ENG RISK FROM MOVING P ARTS RISK OF BURNS RISK OF F ALLING IMPORT ANT SAFETY INSTRUCTIONS (cont’d) WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT MOVING P ARTS SUCH AS THE PULLEY , FL YWHEEL, AND BEL T CAN CAUSE SERIOUS INJUR Y IF THEY COME INTO CONT ACT WITH YOU OR YOUR CLOTHING. A TTEM ...

  • Porter-Cable CPF6020 - page 6

    6-ENG CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressure. ASME: American Society of Mechanical Engineers; made, tested, inspected, and register ed to meet the standards of ASME. California Code: Unit may comply with Califor nia Cod ...

  • Porter-Cable CPF6020 - page 7

    7-ENG DESCRIPTION OF OPERA TION Drain V alve (not shown): The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Motor Thermal Overload Protector (not shown): The electric motor has an automatic thermal overload protector . If the motor overheats for any r eason, the thermal overload protect ...

  • Porter-Cable CPF6020 - page 8

    8-ENG INST ALLA TION Installing Handles, Wheel, and Rubber Foot (Fig. 2) THE WHEELS AND HANDLE DO NOT PROVIDE ADEQUA TE CLEARANCE, ST ABILITY OR SUPPORT FOR PULLING THE UNIT UP AND DOWN ST AIRS OR STEPS. THE UNIT MUST BE LIFTED, OR PUSHED UP A RAMP . 1. Submer ge handle grip (A) into warm soapy water to make installation easier . Remove handle grip ...

  • Porter-Cable CPF6020 - page 9

    9-ENG Location of the Air Compr essor Locate the air compressor in a clean, dry , and well-ventilated area. The air filter must be kept clear of obstructions which could r educe air flow to the air compr essor . The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air . ...

  • Porter-Cable CPF6020 - page 10

    10-ENG GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK! In the event of a short circuit, gr ounding reduces the risk of shock by providing an escape wire for the electric current. This air compr essor must be properly gr ounded. If these gr ounding instructions are not completely understood, or if in doubt as to whether the compr essor is properly ...

  • Porter-Cable CPF6020 - page 11

    11-ENG BREAK-IN PROCEDURES Serious damage may result if the following break-in instructions ar e not closely followed. This pr ocedure is r equir ed befor e the air compressor is put into service. (before the hose is installed), the check valve is r eplaced, or a complete compressor pump is replaced. The pr ocedure: 1. Make sur e the pressure switc ...

  • Porter-Cable CPF6020 - page 12

    12-ENG SERVICE INSTRUCTIONS Air Filter - Inspection and R Air Filter - Inspection and R Air Filter - Inspection and R Air Filter - Inspection and R Air Filter - Inspection and R eplacement eplacement eplacement eplacement eplacement Keep the air filter clean at all times. Do not operate the compressor with the air filter removed. A dirty air filter ...

  • Porter-Cable CPF6020 - page 13

    13-ENG 5. Unscr ew the check valve using a socket wrench. 6. Check that the valve disc moves freely inside the check valve and that the spring holds the disc in the upper , closed position. The check valve may be cleaned with a strong solvent. 7. Apply sealant to the check valve threads. Reinstall the check valve. 8. Replace the pressure r elease t ...

  • Porter-Cable CPF6020 - page 14

    14-ENG CAUSE PERFORMING REP AIRS MA Y EXPOSE VOL T AGE SOURCES, MOVING P ARTS OR COMPRESSED AIR SOURCES. PERSONAL INJUR Y MA Y OCCUR. PRIOR TO A TTEMPTING ANY REP AIRS, UNPLUG THE AIR COMPRESSOR AND BLEED OFF ALL AIR T ANK AIR PRESSURE. PROBLEM CORRECTION TROUBLESHOOTING GUIDE Excessive tank pressure - safety valve pops off. Pressure switch does no ...

  • Porter-Cable CPF6020 - page 15

    15-ENG CAUSE PROBLEM CORRECTION Motor will not run or restart. Motor overload pr otection switch has tripped. T ank pressure exceeds pr essure switch “cut-in” pr essure. W rong gauge wire or length of extension cor d. Check valve stuck open. Loose electrical connections. Possible malfunctioning motor or starting capacitor . Paint spray on inter ...

  • Porter-Cable CPF6020 - page 16

    16-ENG Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Possible defect in safety valve. Air leak from safety valve. CAUSE PROBLEM CORRECTION Knocking Noise. Malfunctioning check valve. Remove and clean, or replace. Compressor is not supplying enough air to operate accessories. Prolonged excessive use o ...

  • Porter-Cable CPF6020 - page 17

    17-ENG ACCESSORIES Accessories can be found at the stor e from which the unit was purchased or at a local hardware store. PLUMBING COMPONENTS CONNECTORS Connects components that have similar NPT threads; Male or Female. 360 O SWIVEL CONNECTOR Eliminates hose twist and improves tool handling. ADAPTERS Combines components that have different NPT thre ...

  • Porter-Cable CPF6020 - page 18

    18-ENG LIMITED WARRANTY POR TER-CABLE CORPORA TION warrants to the original purchaser that each new air compressor and service part is free fr om defects in material and workmanship and agrees to repair or replace under this warranty any defective pr oduct or part as follows fr om the original date of purchase. 5 YEARS – Limited warranty on 2-sta ...

Fabbricante Porter-Cable Categoria Air Compressor

I documenti che otteniamo dal fabbricante del dispositivoPorter-Cable CPF6020 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Porter-Cable
- manuali per l’uso CPF6020
- schede prodotto Porter-Cable
- opuscoli
- o etichette energetiche Porter-Cable CPF6020
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Porter-Cable CPF6020.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Porter-Cable CPF6020, manuali di manutenzione, brevi manuali o manuali utente Porter-Cable CPF6020. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Porter-Cable CPF6020.

Manuali per l’uso simili

Manuale completo del dispositivo Porter-Cable CPF6020, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Porter-Cable CPF6020 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Porter-Cable CPF6020.

Il manuale per l’uso completo Porter-Cable, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Porter-Cable CPF6020 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Porter-Cable CPF6020, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Porter-Cable CPF6020 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Porter-Cable CPF6020 - che ci dovrebbe aiutare nei primi passi durante l'uso Porter-Cable CPF6020
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Porter-Cable CPF6020
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Porter-Cable CPF6020 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Porter-Cable CPF6020?

Utilizza il modulo sottostante

Se non hai risolto il problema con Porter-Cable CPF6020 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Porter-Cable CPF6020 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)