Manuale per l’uso Maytag HRN11275P

48 pagine 0.91 mb
Scarica

Vai alla pagina of 48

Summary
  • Maytag HRN11275P - page 1

    1 www.maytagwaterheaters.com PRINTED IN THE U.S.A. 0505 P ART NO. 66001897 18 468 3-0 01 FOR POT ABLE W A TER HEA TING ONL Y NOT SUIT ABLE FOR SP ACE HEA TING NOT FOR USE IN MANUF ACTURED (MOBILE) HOMES Model Numbers For Y our Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS W A TER HEA TER. POWER VENT GAS W A TER HEA TER USER’S GUIDE Series T ...

  • Maytag HRN11275P - page 2

    2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely import ant in the installation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety ...

  • Maytag HRN11275P - page 3

    3 SAFETY PRECAUTIONS ...

  • Maytag HRN11275P - page 4

    4 T ABLE OF CONTENTS SAFE INST ALLA TION, USE AND SER VICE ............................................................................................. .......................................... 2 SAFETY PRECAUTIONS ..................................................................................................................................... ...

  • Maytag HRN11275P - page 5

    5 T ANK RECOVERY DIMENSIONS CAP ACITY TYPE R ATE GALS. VENT PIPE DIAMETER I N INCHES (mm) IN GALS O F B T U PER HOUR INCHES INCHES HEIGHT TOP OF MODEL NUMBER (LITERS) G A S R A T E @ 90°F RISE (mm) (mm) DRAFT HOOD HRN1 1240P 4 0 (151) N A TURAL 40,000 46.0 3" (76)** 20" (508) 71 1/2" (1,816) *HRN31240P 4 0 (151) N A TURAL 40,000 46. ...

  • Maytag HRN11275P - page 6

    6 ACCESSORIES AND TOOLS NEEDED Accessories T o simplify the installation Maytag has available the installation p art s shown below . Y ou may or may not need all of these accessories depending on your type of installation. Call Mayt ag Customer Service at 1-800-788-8899 for an authorized installer . EXP ANSION T ANKS FOR THERMAL EXP ANSION CONDITIO ...

  • Maytag HRN11275P - page 7

    7 INSTRUCTIONS FOR INST ALLA TION 1. Turn “OFF” the gas supply to the water heater . If the main gas line Shut-off valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 1 and 2. 2. Turn “OFF” the water sup ...

  • Maytag HRN11275P - page 8

    8 TYPICAL INST ALLA TION GET T O KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe B Blower C Anode D Hot Water Outlet E Standard Pipe Fittings F Gas Supply G Manual Gas Shut-off V alve H Ground Joint Union * INST ALL IN ACCORDANCE WITH LOCAL CODES. * DRIP LEG AS REQUIRED BY LOCAL CODES. FIGURE 7. I Drip Leg (Sediment T rap) J Inner Door K Outer ...

  • Maytag HRN11275P - page 9

    9 FIGURE 8. This appliance has been design certified as complying with American National Standard/CSA Standard for water heaters and is considered suitable for: Water (Potable) Heating: All models are considered suitable for water (potable) heating. HOTTER W A TER CAN SCALD: W ater heaters are intended to produce hot water . Water heated to a tempe ...

  • Maytag HRN11275P - page 10

    10 Fact s to Consider About the Location Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Whe ...

  • Maytag HRN11275P - page 11

    11 INST ALLA TIONS IN AREAS WHERE FLAMMABLE LIQUIDS (V APORS) ARE LIKEL Y T O BE PRESENT OR STORED (GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable liquids (such as gasoline, solvents, propane [LP or butane, etc.] and other substances such as adhesives, etc.) emit flammable vapors which can be ignited by a gas water heater ’s pilot light or ...

  • Maytag HRN11275P - page 12

    12 • 12” minimum from the ground, 9” ceiling overhangs, see Figure 1 1. FIGURE 11. • The Power V ent outlet terminal shall terminate at least 36” above any forced air inlet into the building located within 10 feet, see Figure 12. • The Power V ent outlet terminal shall terminate at least 4 feet below , 4 feet horizontally from or 1 foot ...

  • Maytag HRN11275P - page 13

    13 FIGURE 16. Insulation Blankets Insulation blankets available to the general public for external use on gas water heaters are not necessary with Maytag products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Y our Maytag water heater meets or exceeds the National Appliance Energy Co ...

  • Maytag HRN11275P - page 14

    14 B. ALL AIR FROM OUTDOORS: (See Figures 18, 19 and 20) The confined space shall be provided with two permanent openings, one commencing within 12 inches (30 cm) of the top and one commencing within 12 inches (30 cm) from the bottom of the enclosure. The openings shall communicate directly , or by ducts, with the outdoors or spaces (crawl or attic ...

  • Maytag HRN11275P - page 15

    15 Figure 22 shows the typical attachment of the water piping to the water heater . The water heater is equipped with 3/4” NPT water connections for 40,000 Btuh models and 1 inch water connections for 70,000 and 75,000 Btuh models. NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet conne ...

  • Maytag HRN11275P - page 16

    16 Secure all insulation using tape. FIGURE 23. T emperature-Pressure Relief V alve This heater is provided with a properly certified combination temperature - pressure relief valve by the manufacturer . The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment of mater ...

  • Maytag HRN11275P - page 17

    17 The temperature-pressure relief valve must be manually operated at least once a year . Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be ex ...

  • Maytag HRN11275P - page 18

    18 USE WITHOUT POWER CORD If power cord cannot be used, then follow these wiring instructions. • Provide a way to easily shut off the electric power when working on the water heater . This could be with a circuit breaker or fuse block in the entrance box or a separate disconnect switch. • Install and connect a circuit directly from the main fus ...

  • Maytag HRN11275P - page 19

    19 V enting T o insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be utilized. Do not install other gas appliances on the same vent with this water heater as this will adversely affect the operation on the water heater . The combustion and ventilation air flow must not be obstructed. The power vent water heat ...

  • Maytag HRN11275P - page 20

    20 75 GALLON 70,000 AND 75,000 BTU/HR MODELS ONL Y - OPTIONAL 4” VENT PIPING 4” PVC, ABS or CPVC Schedule 40 vent piping: • A wire screen to fit a 4” PCV , ABS or CPVC Schedule 40 - 45 o vent cap is supplied with the water heater . • A 4” PVC, ABS or CPVC Schedule 40 - 45 o vent cap (must be supplied locally). • A 3” PVC, ABS or CPV ...

  • Maytag HRN11275P - page 21

    21 • The water heater requires its own (separate) venting system. • 2” and 3” PVC, ABS or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all 40 and 50 gallon 40,000 BTU/HR models. • It cannot be connected to existing vent piping or chimney . • It must terminate horizontally to the outdoors. NOTE: Se ...

  • Maytag HRN11275P - page 22

    22 40 AND 50 GALLON 40,000 BTU/HR MODELS See Chart below for maximum length. FIGURE 39. • The total vertical and horizontal vent run cannot exceed the maximum length with the number of 90 o elbows as specified in the following tables. If more are required the venting distance must be reduced 5 feet for every 90 o elbow . 75 GALLON 70,000 AND 75,0 ...

  • Maytag HRN11275P - page 23

    23 75 GALLON 70,000 AND 75,000 BTU/HR MODELS ONL Y 3” DIA. VENT NUMBER OF MAX. LENGTH (FT .) 9 0 ELBOWS*(Inside bldg.) 60 1 55 2 50 3 45 4 40 5 35 6 75 GALLON 70,000 AND 75,000 BTU/HR MODELS ONL Y - OPTIONAL 4” VENT PIPING 4” DIA. VENT NUMBER OF MAX. LENGTH (FT .) 90 o ELBOWS*(Inside bldg.) 100 1 95 2 90 3 85 4 80 5 75 6 ALL 40 AND 50 GALLON ...

  • Maytag HRN11275P - page 24

    24 FIGURE 42. The 3” )or optional 2” or 4”) PVC, ABS or CPVC Schedule 40 vent pipe can be run from the water heater through the wall or from the wall to the water heater , whichever is most convenient. The vent pipe must extend a minimum of 1 1/2” through the exterior wall. Extending the vent cap as far as possible from the surface of the e ...

  • Maytag HRN11275P - page 25

    25 • 4” and 3” PVC, ABS or CPVC Schedule 40 piping and fittings are acceptable materials for vent system on all 75 gallon 70,000 and 75,000 BTU/HR models and must be supplied locally . FIGURE 46. ALL 40 AND 50 GALLON 40,000 BTU/HR MODELS - OPTIONAL 2” VENT PIPING 2” PVC, ABS or CPVC Schedule 40 vent piping: • A wire screen to fit 2” P ...

  • Maytag HRN11275P - page 26

    26 ALL 40 AND 50 GALLON 40,000 BTH/HR MODELS ONL Y - OPTIONAL 2” VENT PIPING 2” DIA. VENT NUMBER OF MAX. LENGTH (FT .) 9 0 o ELBOWS* 50 1 45 2 40 3 35 4 30 5 25 6 * T wo 45 o elbows are equivalent to one 90 o elbow. One 90 o elbow equals 5 feet of equivalent vent length. Gas Piping Make sure the gas supplied is the same type listed on the model ...

  • Maytag HRN11275P - page 27

    27 • Contaminants in gas lines can cause fire or explosion. • Clean all gas piping before installation. • Install drip leg in accordance with NFP A 54. Sediment T rap s Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pi ...

  • Maytag HRN11275P - page 28

    28 OPERA TING INSTRUCTIONS This water heater is equipped with an electronically operated venting system and electronic control. For the burner to come on, the water heater thermostat must call for heat. Then the system will begin sequencing, each section proving itself before gas is allowed to flow to the burner . BEFORE THE W A TER HEA TER WILL OP ...

  • Maytag HRN11275P - page 29

    29 Operating Propane gas is heavier than air . Should there be a leak in the system, the gas will settle near the ground. Basements, crawl spaces, skirted areas under manufactured (mobile) homes (even when ventilated), closets and areas below ground level will serve as pockets for the accumulated gas in the area. Search for odor of gas by sniffing ...

  • Maytag HRN11275P - page 30

    30 are also available. Consult Maytag Customer Service (1-800-788-8899) . Follow manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the T emperature Regulation section in this manual, see Figure 52. Never allow small children to use a hot water tap, or to draw their own bath wat ...

  • Maytag HRN11275P - page 31

    31 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. • If you cannot reach your gas supplier , call the fire department. C . Use only your hand to push in or turn the gas control button. Never use tools. If the c ...

  • Maytag HRN11275P - page 32

    32 SERVICE AND MAINTENANCE • Flue gases may escape if vent pipe is not connected. • Be alert for obstructed, sooted or deteriorated vent system to avoid serious injury or death. • Do not store corrosive chemicals in vicinity of water heater . • Chemical corrosion of flue and vent system can cause serious injury or death T ank (Sediment) Cle ...

  • Maytag HRN11275P - page 33

    33 L.P . Gas Control V alve & Burner Assembly Replacement Information For Prop ane (L.P .) Models Only Y our water heater is equipped with a Propane (L.P .) gas control valve and a main burner assembly with left hand threads for the following fittings and their connections. • The connection between the manifold and the gas control valve (A an ...

  • Maytag HRN11275P - page 34

    34 NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain. • CLOSE the drain valve. • Follow instructions in the Filling The Water heater section. • Follow the lighting instructions in the Operation section ...

  • Maytag HRN11275P - page 35

    35 Start Up Conditions Condensation Whenever the water heater is filled with cold water , some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensation. This usually happens when: • A new water heater is filled with cold water for the first time. • Burning gas produces water vap ...

  • Maytag HRN11275P - page 36

    36 hot water lines. Contact Maytag Customer Service at 1-800-788-8899 for further information concerning an Anode Replacement Kit and this Chlorination T reatment. If the smelly water persists after the anode replacement and chlorination treatment, we can only suggest that chlorination or aeration of the water supply be considered to eliminate the ...

  • Maytag HRN11275P - page 37

    37 Leakage Checkpoints Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water . Never use this water heater unless it is completely filled with water . T o prevent damage to the tank, the t ank must be filled with w ...

  • Maytag HRN11275P - page 38

    38 This troubleshooting guide has been supplied for use by qualified service personnel who have a complete understanding of both electricity and gas. Label all wiring before disconnecting any wiring; to ensure correct reconnection. Failure to follow this instruction could caus e improper and possible dangerous operation, resulting in DEA TH, SERIOU ...

  • Maytag HRN11275P - page 39

    39 PROBLEM SOLUTION An open earth ground circuit to the 1. Check that the earth ground connection is ignition system. properly connected. 2. Check that the ground conductor on the water heater is properly connected. Wiring error or a high resistance to 1. Check for proper connection of line earth ground. neutral and hot wires. 2. Check that the wat ...

  • Maytag HRN11275P - page 40

    40 These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at 1-800-788-8899 for assistance. Problem Cause Solution Blower will not run. A) “ON/OFF” control switch turned off Turn switch to the “ON” position. B) Blower unplugged. Plug blower back into 1 15 VAC outlet. C) N ...

  • Maytag HRN11275P - page 41

    41 MODEL NO’S HRN1 1240P 40 Gallon Natural Gas HRN31240P 4 0 Gallon Natural Gas HRP1 1240P 40 Gallon Prop ane Gas (L.P .) HRP31240P 4 0 Gallon Propane Gas (L.P .) * Not Shown. Now that you have purchased this gas water heater , should a need ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an autho ...

  • Maytag HRN11275P - page 42

    42 MA YT AG GAS W A TER HEA TERS REP AIR P ARTS LIST Now that you have purchased this gas water heater , should a need ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an authorized servicer . Be sure to provide all pertinent facts when you call or visit. THIS IS A REP AIR P ARTS LIST , NOT A P ACKIN ...

  • Maytag HRN11275P - page 43

    43 MA YT AG GAS W A TER HEA TERS REP AIR P ARTS LIST MODEL NO’S HRN1 1275P 75 Gallon Natural Gas HRN31275P 7 5 Gallon Natural Gas HRP1 1275P 75 Gallon Propane Gas (L.P .) HRP31275P 75 Gallon Propane Gas (L.P .) Now that you have purchased this gas water heater , should a need ever exist for repair parts or service, simply call Maytag Customer Ser ...

  • Maytag HRN11275P - page 44

    44 66001010 9002404 6600101 1 9001609 66001012 9001608 66001013 ETC2X 66001014 ETC5X 66001015 9002401 66001020 9000734 66001021 9001584 66001025 0230120 66001027 900241 1 66001029 9000281 66001030 9002444 66001034 9002445 66001035 0230141 66001041 0230224 66001046 0230124 66001047 0230123 66001052 9002059 66001068 9001453 66001 105 9002769 66001 14 ...

  • Maytag HRN11275P - page 45

    45 NOTES ...

  • Maytag HRN11275P - page 46

    46 NOTES ...

  • Maytag HRN11275P - page 47

    47 NOTES ...

  • Maytag HRN11275P - page 48

    48 FULL ONE YEAR W ARRANTY For one year from the date of original retail purchase, any part which fails in normal home use will be repaired or replaced free of charge. If a leak occurs in the tank, a new water heater of the closest capacity and quality then available, will be replaced free of charge. The warranty of the replacement is the balance o ...

Fabbricante Maytag Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoMaytag HRN11275P possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Maytag
- manuali per l’uso HRN11275P
- schede prodotto Maytag
- opuscoli
- o etichette energetiche Maytag HRN11275P
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Maytag HRN11275P.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Maytag HRN11275P, manuali di manutenzione, brevi manuali o manuali utente Maytag HRN11275P. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Maytag HRN11275P.

Manuali per l’uso simili

Manuale completo del dispositivo Maytag HRN11275P, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Maytag HRN11275P dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Maytag HRN11275P.

Il manuale per l’uso completo Maytag, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Maytag HRN11275P - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Maytag HRN11275P, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Maytag HRN11275P che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Maytag HRN11275P - che ci dovrebbe aiutare nei primi passi durante l'uso Maytag HRN11275P
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Maytag HRN11275P
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Maytag HRN11275P in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Maytag HRN11275P?

Utilizza il modulo sottostante

Se non hai risolto il problema con Maytag HRN11275P con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Maytag HRN11275P è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)