  • Friedrich CP08A10 - page 1

    Room Air Conditioner Ser vice and P ar ts Man ual ZQ08/10;CP08/10/12 (06/05) Z Q 08 B 1 0 Z Q 10 B 1 0 C P 08 A 1 0 C P 10 A 1 0 C P 1 2 A 1 0 ...

  • Friedrich CP08A10 - page 2

    —2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ................................2 1.2 INSULATION RESISTANCE TEST .................2 1.3 SPECIFICATIONS ...........................................3 1.4 FEATURES......................................................4 1.5 CONTROL LOCATIONS .................................4 2. DISASSEMBL Y INSTR UCTIONS 2.1 ...

  • Friedrich CP08A10 - page 3

    7, 800 10, 000 7, 800 1 2 , 0 0 0 80 0 1 , 02 0 7 3 0 1 , 1 1 0 7 . 6 9 . 2 6 . 6 1 0 . 2 9 . 7 1 0 . 8 2 6 . 7 ( D B ) * 1 9 . 4 ( W B ) * * 3 5 ( D B ) * 2 3 . 9 ( W B ) ** 3 0 0 g( 1 0 . 6o z ) 5 2 0 g( 1 8 . 3o z ) 5 2 5 g( 1 8 . 5o z ) 5 1 0 g( 1 8 . 0o z ) 2 R O W 1 1 S T A C K S 3 R O W 1 1 S T A C K S 2 R O W 1 0 S T A C K S 3 R O W 1 2 S T ...

  • Friedrich CP08A10 - page 4

    — 4 — 1.4 FEA TURES • Designed for COOLING ONLY. • Powerful and whispering cooling. • Slide-in and slide-out chassis for the simple installation and service. • Low air-intake, top cooled-air discharge. 1.5 CONTR OL LOCA TIONS • THERMOSTAT (Fig A) Thermostat will automatically control the temperature of the discharge air. For a cooler ...

  • Friedrich CP08A10 - page 5

    — 5 — Precaution: The Remote Control unit will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Control unit and the air conditioner. POWER BUTTON To turn the air conditioner ON. To turn the air conditioner OFF, push the button again . This button takes priority ...

  • Friedrich CP08A10 - page 6

    — 6 — 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Open the lnlet grille downward and remove the air filter. 2. Remove the screw which fastens the front grille.(See Figure 1) 3. Pull the front grille from the right side. 4. Remove the front grille.(There are 4 hooks.) 5. Re-install the components by referring to the removal procedure, above. 2. ...

  • Friedrich CP08A10 - page 7

    — 7 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE AND TURBO F AN 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the control box. (Refer to section 2.1.3) 4. Remove the 4 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the air guide upper. 7. Rem ...

  • Friedrich CP08A10 - page 8

    — 8 — 2.2.3 SHROUD 1. Remove the fan. (Refer to section 2.2.2) 2. Remove the shroud. (See Figure 8) 3. Re-install the components by referring to the removal procedure, above. 2.3 ELECTRICAL P AR TS 2.3.1 O VERLO AD PRO TECT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the nut which fastens the terminal cover. 3. Remove the termi ...

  • Friedrich CP08A10 - page 9

    — 9 — 2.3.3 CAP A CIT OR 1. Remove the control box. (Refer to section 2.1.3) 2. Open the top cover from the control box. (See Figure 11) 3. Pull out the capacitor from the control box. 4. Disconnect all the leads of capacitor terminals. 5. Re-install the components by referring to the removal procedure, above. 2.3.4 PO WER CORD 1. Remove the co ...

  • Friedrich CP08A10 - page 10

    — 10 — 2.3.5 MO T OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the turbo fan. (Refer to section 2.2.1) 3. Remove the fan. (Refer to section 2.2.2) 4. Remove the 4 screws which fasten the motor to the air guide. (See Figure 13) 5. Remove the motor. 6. Re-install the components by referring to the removal procedure, above.(See Fig ...

  • Friedrich CP08A10 - page 11

    — 11 — — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM . Remove the valve when finished. 2. After discharging the u ...

  • Friedrich CP08A10 - page 12

    — 12 — Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin ch- off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SIDE) SEE INSETS BELOW ...

  • Friedrich CP08A10 - page 13

    DEFROST HEAT COOL INDOOR DESIRED ENERGY SAVER AIR PURYFIER AUTO RESTART FAN FAN DRY 354(13 / ") 29 490(19 / ) 3 8" 29(1 / ) 5 32" 18( / ) 23 32" 126.5(4 / ) 31 32" 32 510 20 3 32 — 1 3 — 3 . T R OUBLESHO O TING GUIDE 3 .1 OUTSIDE DIMENSIONS unit: mm(in c h) DEFROST HEAT COOL INDOOR DESIRED ENERGY SAVER AIR PURYFIER AUTO ...

  • Friedrich CP08A10 - page 14

    — 1 4 — 3 .2 PIPING SYSTEM Figure 17 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle. MOTOR COMPRESSOR OIL (LIQUID REFRIGERANT) CAPILLARY TUBE OUTSIDE COOLING AIR FOR REF ...

  • Friedrich CP08A10 - page 15

    — 1 5 — 3 .3 T R OUBLESHO O TING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit runs but poor cooling. Ineffective Cooling Chec ...

  • Friedrich CP08A10 - page 16

    — 16 — Fails to Start Check circuit breaker and fuse. Gas leakage of feeler bulb of thermostat Check control switch. Fan only fails to start. Improper wiring. Defect of fan motor capacitor . Irregular motor resistance ( ). Irregular motor insulation ( ). Replacement of fan motor . Regular but fails to start. Replacement of compressor (locking o ...

  • Friedrich CP08A10 - page 17

    — 17 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if defective. Connect wire. Refer to wiring diagram for terminal identification. R ...

  • Friedrich CP08A10 - page 18

    — 18 — COMPLAINT CAUSE REMEDY Check the position of knob . If not at the coldest setting, advance the knob to this setting and restart unit. Check continuity of the thermostat. Replace thermostat if circuit is open. Check the capacitor. Replace if not within ±10% of manufacturers rating. Replace if shorted, open, or damaged. Check the compress ...

  • Friedrich CP08A10 - page 19

    MOTOR ASSY CAPACITOR COMPRESSOR OVERLOAD PROTECTOR DC PCB ASSEMBLY AC PCB ASSEMBLY THERMISTOR THERMOSTAT ROTARY SWITCH 1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1 S S S S S S S S S LOCATION NO. DESCRIPTION RE- MARKS Q'TY PER SET 4 . SCHEM A TIC DI A GRAM — 19 — MOTO R COMP . CAP ACIT OR DC PCB ASSEMBL Y THERMISTOR AC PCB ASSEMBL Y WIRING DIAGRAM 3 ...

  • Friedrich CP08A10 - page 20

    5. EXPLODED VIEW — 2 0— 130910 149980 346811 359012 W48602 349001 352390-2 352390-1 W0CZZ 135500 147581 147582-2 559011 349480 352113 352113 W48602 148000 354210 152302 264110 249950 149410 266003 269310 130410 550140 35211A 554160 567502 135312 135313 554031 352115 552111 268714 W0CZZ 135500 249950 263230 268712 238310 264110 237200 731373 267 ...

  • Friedrich CP08A10 - page 21

    — 2 1 — 6. REPL A CEMENT P A R TS LIST R: Service Parts N: Non Service Parts Z Q 08 B 1 0 Z Q 10 B 1 0 C P 08 A 1 0 C P 10 A 1 0 C P 1 2 A 1 0 Loc No FRIEDRICH Description 130410 67302924 BASE ASSEMBLY,SINGLE 130910 67303711 CABINET ASSEMBLY,SINGLE 135312 67306014 GRILLE ASSEMBLY,FRONT(SINGLE) 135313 67306109 GRILLE,INLET 135500 67300311 COVER ...

  • Friedrich CP08A10 - page 22

    — 2 2 — Loc No FRIEDRICH Description 130410 67302913 BASE ASSEMBLY,SINGLE 130910 67303711 CABINET ASSEMBLY,SINGLE 135312 67306014 GRILLE ASSEMBLY,FRONT(SINGLE) 135313 67306109 GRILLE,INLET 135500 67300311 COVER 147581 67306207 LOUVER,HORIZONTAL 147582-1 67306260 LOUVER,VERTICAL 147582-2 67306261 LOUVER,VERTICAL 148000 67303909 BRACE 149410 6730 ...

  • Friedrich CP08A10 - page 23

    — 2 3 — Loc No FRIEDRICH Description 130410 67302913 BASE ASSEMBLY,SINGLE 130910 67303711 CABINET ASSEMBLY,SINGLE 135312 67306014 GRILLE ASSEMBLY,FRONT(SINGLE) 135313 67306109 GRILLE,INLET 135500 67300310 COVER 147581 67306207 LOUVER,HORIZONTAL 147582-1 67306260 LOUVER,VERTICAL 147582-2 67306261 LOUVER,VERTICAL 148000 67303909 BRACE 149980 6730 ...

  • Friedrich CP08A10 - page 24

    — 2 4 — Loc No FRIEDRICH Description 130410 67302923 BASE ASSEMBLY,SINGLE 130910 67303710 CABINET ASSEMBLY,SINGLE 135312 67306013 GRILLE ASSEMBLY,FRONT(SINGLE) 135313 67306108 GRILLE,INLET 135500 67300310 COVER 147581 67306206 LOUVER,HORIZONTAL 147582-1 67306258 LOUVER,VERTICAL 147582-2 67306259 LOUVER,VERTICAL 148000 67303908 BRACE 149980 6730 ...

  • Friedrich CP08A10 - page 25

    — 2 5 — Loc No FRIEDRICH Description 130410 67302922 BASE ASSEMBLY,SINGLE 130910 67303710 CABINET ASSEMBLY,SINGLE 135312 67306013 GRILLE ASSEMBLY,FRONT(SINGLE) 135313 67306108 GRILLE,INLET 135500 67300310 COVER 147581 67306206 LOUVER,HORIZONTAL 147582-1 67306258 LOUVER,VERTICAL 147582-2 67306259 LOUVER,VERTICAL 148000 67303908 BRACE 149980 6730 ...

  • Friedrich CP08A10 - page 26

    — 2 6 — MEMO ...

  • Friedrich CP08A10 - page 27

    — 2 7 — MEMO ...

  • Friedrich CP08A10 - page 28

    Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com Use F actor y Cer tified P ar ts... ...

Fabbricante Friedrich Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoFriedrich CP08A10 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Friedrich
- manuali per l’uso CP08A10
- schede prodotto Friedrich
- opuscoli
- o etichette energetiche Friedrich CP08A10
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Friedrich CP08A10.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Friedrich CP08A10, manuali di manutenzione, brevi manuali o manuali utente Friedrich CP08A10. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Friedrich CP08A10.

Manuali per l’uso simili

Manuale completo del dispositivo Friedrich CP08A10, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Friedrich CP08A10 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Friedrich CP08A10.

Il manuale per l’uso completo Friedrich, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Friedrich CP08A10 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Friedrich CP08A10, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Friedrich CP08A10 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Friedrich CP08A10 - che ci dovrebbe aiutare nei primi passi durante l'uso Friedrich CP08A10
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Friedrich CP08A10
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Friedrich CP08A10 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Friedrich CP08A10?

Utilizza il modulo sottostante

Se non hai risolto il problema con Friedrich CP08A10 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Friedrich CP08A10 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)