Manuale per l’uso Kowa RB-525-B04

40 pagine 0.38 mb
Scarica

Vai alla pagina of 40

Summary
  • Kowa RB-525-B04 - page 1

    RB-525-B04 Operations Manual Auto Refkeratometer ...

  • Kowa RB-525-B04 - page 2

    RB-525-B04 1 INTRODUCTION This manual co ntains inform ation on correct handli ng and op erational proced ures as well as safety consideration pert inent to KW -2000 Before carrying out measurement and/or adjustm ent, re ad the instruct ions thoroughly so that ef fective operation is ensure d. As this consti tutes an im portant reference and us er ...

  • Kowa RB-525-B04 - page 3

    RB-525-B04 2 CAUTION  Always take great care when op erating KW-2000. Malfunction or damage to the i nstrument coul d occur .  Cut the power im mediately if m alfunction occ urs during operatio n. Damage to the equipm ent or personal injury will result. Consult y our dealer , if repair work needs to be carried out.  At no tim e attempt to ...

  • Kowa RB-525-B04 - page 4

    RB-525-B04 3 Contents Introduction ............................................................................................................................. 1 Safety Consideration ............................................................................................................... 1 Contents ........................................... ...

  • Kowa RB-525-B04 - page 5

    RB-525-B04 4 Accessories Model eye: 1 (with a contact lens holder) Power cord: 1 (2.5m) Printer paper rol e: 3 (width 57mm) T wo packed and one installed into the body Fuse: 2 (T2A 250V) Pack of chin rest line rs: 1 (1,000 sheet s) Chine rest liner pin: 2 Dustproof cover: 1 Operations manual: 1 Use accessories specifie d by us to avoid any malfu nc ...

  • Kowa RB-525-B04 - page 6

    RB-525-B04 5 1. Parts Identification Head rest Eye mar k Chin re s t View w i ndow External interf ace co nnector External monitor ou tput terminal Power plug conn ector Fuse holder Power sw it c h Joys ti ck Measure ment st art sw it ch Rating p late Printer LCD monitor Bod y Base Anti-sliding lock IOL switch Measurement mode selection switch Menu ...

  • Kowa RB-525-B04 - page 7

    RB-525-B04 6 2. Conveyance and Handling Procedure When transporting the instrume nt, make sur e that the body has been secur ely locked. Center the body on to the base so that their edge s are aligned. Push dow n the lock while turni ng right until both body and base are firmly fixed to each oth er . 3. Installation Environment 1) Do not exp ose th ...

  • Kowa RB-525-B04 - page 8

    RB-525-B04 7 4. Safeguard Summary 1. KW-2000 is a precisi on optical instr ument. Always handle wi th care and a void dropping i t accidentally . 2. Ensure that the ins trument is properly grounded when connected to the power source. 3. Do not touch the optical parts with fingers an d be sure to avoid dust, as th eir measuring acc uracy could be ad ...

  • Kowa RB-525-B04 - page 9

    RB-525-B04 8 5. Preparation 5.1 Setting (1) Set a roll of printer paper in the printer . Refer to ' 1 1.1 Reloadin g Printer Paper ' for the procedure. (2) Set and fix the chin rest liners wi th the chin rest liner pins on the c hin rest. Refer to the figure on the right.  Always use the chin rest liners following ab ove.  For sanit ...

  • Kowa RB-525-B04 - page 10

    RB-525-B04 9 5.2 Applying P o we r (1) Confirm that the power is 'OFF' ( ). (2) Insert the power c ord into the instrument' s power plug connector . Then in sert the plug int o a general-purpose outlet. (3) T urn the power switch 'ON' ( ). I O POW ER T 2A 250V I O POW ER T 2A 250V Always make sure that the cable is grounded ...

  • Kowa RB-525-B04 - page 11

    RB-525-B04 10 5.3 Standby When the power is turned on, the s creen as shown below appears on the LCD m onitor, which is re ady to take measurem ents. Increm ent o f me asurem ent values V er tex distan ce Cylindrical mark Eye sel ectio n indicatio n Refrac tion data displa y area Reticle m ark Minim um pupil diamet er meas urable Kerat om etr y dat ...

  • Kowa RB-525-B04 - page 12

    RB-525-B04 11 5.4 Switch Fu n c ti o n Operating switc hes below a L CD monitor corres pond to the ic ons display ed on the b ottom of the scree n. For normal measurem ent, each icon functions as bel ow . Measurement start switch : starts the m easure ment. Menu switc h Measure ment m ode select ion switch Print sw itch IOL switc h Powe r indica to ...

  • Kowa RB-525-B04 - page 13

    RB-525-B04 12 6. Measurement 6.1 Measurem e n t Flow (1) Rotate an anti-sliding lo ck clo ckwis e to release it. (2) Have the exam inee place his/her chi n on the chin rest and his/her forehead ag ainst th e head rest . Then, have him/her see a tar get. (3) Check from the side and adjust the chin rest so that t he examinee' s eye level is in l ...

  • Kowa RB-525-B04 - page 14

    RB-525-B04 13 6.2 Alignmen t (1) Operate a joystick t o bring a ce nter of the subject eye onto a reticle mark. When the subject eye is focused on, a kerato ring appears. (2) Keeping the reticl e mark in the center of the subject eye, try to focus the subject eye, and t hen, an alignm ent mark ( ) will appear . Then, operate the joystick to bri ng ...

  • Kowa RB-525-B04 - page 15

    RB-525-B04 14 6.3 Measurem e n t Results R1 7 . 8 5 R2 7 . 7 4 A9 0 S- 4 . 7 5 C- 0 . 2 5 A9 0 A9 0 PD= 6 7 NP D = 2 ( 63 0 ) 12 K er. Re f. 0. 25 ( 1 ) ( 1 ) R R / K MEN U Pupil l a ry Dist an ce K er at om et ry me as ur eme n t r esul t Ax is An g l e N ear p u pil l ar y dist an ce R ad iu s of Cu rv at ur e( mi n mu m ) R e f r ac t ive m e ...

  • Kowa RB-525-B04 - page 16

    RB-525-B04 15 6.4 Print Out Normally y ou can print out th e m easurem ent result by pressing PR INT switch after the m easurement. (The icon of PRINT switch in the m onitor turns into bl ue during printi ng.) A maxim um of ten data is recor ded for each eye and the most reliab le among them is indicated as an optimum value. The optimum value is in ...

  • Kowa RB-525-B04 - page 17

    RB-525-B04 16 6.5 Kerato-Pe r i pheral Measurement KW-2000 incorporat es a function to measure not on ly a cent er but also periph eries of a cornea. (1) Press a measurement m ode selection switch to switch over to P .K. mode. P .K. measurem ent screen will appear and a 'measurement gui ding mark' which i ndicates the measurement posi tio ...

  • Kowa RB-525-B04 - page 18

    RB-525-B04 17 (3) Measure the corneal periphery . Have the examinee look at the fixati on tar get that is illuminating. A m easure ment position in the gui ding mark is indicated in blue. C arry out alignment and press the measurement switch. When the m easurement is completed, t he guiding m ark changes blue to light b lue and th e next m easureme ...

  • Kowa RB-525-B04 - page 19

    RB-525-B04 18 6.6 IOL Meas u r ement KW-2000 has the fu nction to m easure the IOL (intraocular lens) implanted eye. When measuring the IOL implante d ey e, press IOL swit ch on the front panel of the body to ac tivate the function. At this time, the icon for IOL switch as well as S, C, and A on the LCD monitor t urns to purple . No. 00001 NAME 200 ...

  • Kowa RB-525-B04 - page 20

    RB-525-B04 19 6.7 Menu Scr e e n Setting Standard measurem ent mode is preset to be ready to use. Howev er , you can easily a lter the setting if necessary . T o enter the menu screen, press a menu switc h below the LCD monitor . 【 Menu Screen 】 ST ART MANUAL AUTO3   AU TO5 REF NORMAL QUICK( 3) STE P 0.25 0. 12 VD( mm) 0 10 12 13. 5 15 CYL ? ...

  • Kowa RB-525-B04 - page 21

    RB-525-B04 20 6.7.1 Each Item Description 【 The First Screen 】  ST ART Selects how to start m easurement. Refer to ' 6.8 Auto Start Function ' for detail. MANUAL: Measurement is taken every time the m easure ment switch is pressed. AUTO 3 : Measurement is automatically star ted when the m easurement requirements are m et. Three mea ...

  • Kowa RB-525-B04 - page 22

    RB-525-B04 21  DA T A SCREEN Measurement results stored in m e mory ar e display ed on the screen. Refer to ' 6.8 Data Screen Function ' for detail. O N : All measurement results are displ ayed on the screen. OFF : No measurement results are dis played on the screen.  W-D(cm) Sets near work distance. W hen measurem ent is taken with ...

  • Kowa RB-525-B04 - page 23

    RB-525-B04 22  OPTION Selects and sets o ptional functi ons. Refer to ' 6.7.2 Optional Function ' for detail. MESSAGE: shifts to the screen for register ing message. N o . : shifts tot he screen for setting ex aminee's num ber . RS232C : shifts to the screen to set RS232C transmission param eters.  DA TE FORM Selects display fo ...

  • Kowa RB-525-B04 - page 24

    RB-525-B04 23 6.7.2 Optional Functions W h e n y o u s e l e c t t h e f u n c t i o n y o u w i s h t o s e t i n ' OPTION ' of Menu screen, yo u can enter each option screen. 【 Each Option Screen and Description 】 I. Message Input Function When this function, yo u can print out regis tered messages in the range of 22 ch aracters/lin ...

  • Kowa RB-525-B04 - page 25

    RB-525-B04 24 II. No. Function Y ou can set or change the exam inee's number , and sel ect whether the num ber is displayed on the screen and whether the n umber is printed ou t. When you select this m enu, the screen below will appear and functio n of each switch will change as followin g. Move the cur sor to selec t the item you w ish to cha ...

  • Kowa RB-525-B04 - page 26

    RB-525-B04 25 III. RS232C Setting Function W ith this function , you can send the m easurement data to an external computer t hrough an interface. The data is sent using ASCII CODE. When you select this m enu, the screen on the left will appear and f unction of each switch will c hange as shown. 【 Each Item Description 】 1. BAUDRA TE : selectio ...

  • Kowa RB-525-B04 - page 27

    RB-525-B04 26 (1) Move the cursor to the item you wish to set/ change with switch and execute with switch. (2) When the setting is completed, pr ess switch to go ba ck to the m enu screen. 【 Connection method 】  Connection D-Sub25pin D-Sub9pin TXD 2 2 RXD RXD 3 3 TXD DSR 6 4 DTR SG (GND) 7 5 SG (GND) DTR 20 6 DSR ※ If you have any inquirie ...

  • Kowa RB-525-B04 - page 28

    RB-525-B04 27 6.8 Auto Star t F u nction KW-2000 incorporat es Auto Start Function. This function st arts measuring aut omatically when a lignment m eets the measurement requirement, a nd also prints out autom atically when the measurement of b oth eyes com pletes. (1) When you wish to measure with auto start function, select ' AUT O3 ' o ...

  • Kowa RB-525-B04 - page 29

    RB-525-B04 28 (6) After both eyes are measured, t he arrow will disappear and the measurem ent result will be automatically printed out. (7) If you wish to conti nue to measure with auto start function , realignment is necessary . When you wish to cancel auto st art f unction, change the setting of 'ST ART' back to 'MANUAL' in t ...

  • Kowa RB-525-B04 - page 30

    RB-525-B04 29 6.9 Data Scre e n F unction Data screen function allows you to check measur em ent results saved in the m emory on the screen. (1) Select ' ON ' in ' DA T A SCREEN ' of the Menu screen. (2) After the measurement, press switch, and the data screen will app ear as shown on the left. (3) Displaying the da ta on the sc ...

  • Kowa RB-525-B04 - page 31

    RB-525-B04 30 6.10 Power Sa v i ng Function Power saving function will st art operating when swit ch operation is suspended with the power on. (The switchover tim e (in minute) can be selected at ' SA VE ' on the mode selection screen. ) T o return to the measurement mode, press any switch (any switch on the front panel or the measurem en ...

  • Kowa RB-525-B04 - page 32

    RB-525-B04 31 7. Tips for Effective Measurement (1) Do not allow externa l light to dire ctly penetrate t he room. (2) Fluctuation of va lues during measurem ent may occur if the examinee looks s omething other t han the target. Ur ge the examinee to concentrate on t he tar get set in front. (3) T alk to the exam inee in a relaxe d and friendly m a ...

  • Kowa RB-525-B04 - page 33

    RB-525-B04 32 8. Error Messages KW-2000 autom atically evaluates measurement co ndition or result and indicates error m essages if it is invalid. Error messages als o appear when abnorm ality is detected in its operational system . When any error m essage appears, always check the sy stem with a supplied model eye. If it appe ars when no abnorm ali ...

  • Kowa RB-525-B04 - page 34

    RB-525-B04 33 9. Contact Lens: Base Curve Measurement Y ou can measure a base c urve of a hard c ontact lens wit h KW-2000. T o do so, attach a contact l ens onto a contac t lens holder of t he model eye as following. (1) Put a small am ount of water on a concave side of th e contact lens holder . (2) Place the contact le ns so that its co nvex sid ...

  • Kowa RB-525-B04 - page 35

    RB-525-B04 34 10. T roubleshooting If there are any m alfunction found, refer to the table below to take appr opriate measures. CAUTION Never disassemble, modify or repair the instrum ent. Personal injury may result from elect ric shock. Symptom Causes and Measures The monitor and power indicator are not turned on. • The power cord m ay be not pr ...

  • Kowa RB-525-B04 - page 36

    RB-525-B04 35 11. Storage and Maintenance 11.1 Reloading P ri n ter Paper 1) Remove a printer cover a nd take a printer paper shaft out. 2) Lift a printer cutter p art and pull up a head-up lever . 3) Set a roll of printer paper , paying attention to direction of the paper rolled up. 4) Insert the loose end o f the paper behind a rubber rolle r . P ...

  • Kowa RB-525-B04 - page 37

    RB-525-B04 36 11.2 Fuse Rep l a cement CAUTION When replacing a fuse, unplug the power cord from the unit before removing the fuse holder . Y ou may be in danger of electric sh ock if you remove the fuse holder without unpluggi ng the po wer cord. When a fuse is blow n, remove a fuse h older at the side of a main uni t for replacem ent. Pushing the ...

  • Kowa RB-525-B04 - page 38

    RB-525-B04 37 11.4 Confirma t i on of Measurement Accuracy It is extremely im portant to chec k operation an d accuracy of the instrument using a supplie d model eye. W e recommend you to check accuracy periodi cal ly . When the measurem ent result of the model eye falls anyw here within the tolerance lis ted below , measurement should be considere ...

  • Kowa RB-525-B04 - page 39

    RB-525-B04 38 12. Specifications Sphere (S) -25 ∼ +25D (step: 0.12/0. 25D) Cylinder (C) 0 ∼± 10D (step: 0.12/0.25D) Refractive Measurem ent Range Axis (A) 0 ∼ 180º (step: 1°) Sphere between − 10 ∼+ 10D : ± 0.25D beyond ± 1 0 : ± 0.5D Measurement Accuracy Cylinder ± 0.25D Radius of Corneal Curvature 5.0 ∼ 10.0mm (step: 0.01mm) C ...

  • Kowa RB-525-B04 - page 40

    RB-525-B04 Prepared: 2002. 12. 4 Printed on recycled paper . Life Science Division No.4-14, 3-chome, Nihonbashi-Honc ho, Chuo-ku, T okyo 103-843 3, Japan Phone: 81(3) 3279-7312 Facsimile: 81(3) 3245-1 109 20001 So. V ermont Ave. T orrance, CA 90502, U.S.A. Phone: 1(310) 327-1913 Facsimile: 1(310) 327-4177 Immermannstrasse 65A 40210 Dusseldorf F .R. ...

Fabbricante Kowa Categoria Telescope

I documenti che otteniamo dal fabbricante del dispositivoKowa RB-525-B04 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Kowa
- manuali per l’uso RB-525-B04
- schede prodotto Kowa
- opuscoli
- o etichette energetiche Kowa RB-525-B04
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Kowa RB-525-B04.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Kowa RB-525-B04, manuali di manutenzione, brevi manuali o manuali utente Kowa RB-525-B04. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Kowa RB-525-B04.

Manuali per l’uso simili

Manuale completo del dispositivo Kowa RB-525-B04, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Kowa RB-525-B04 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Kowa RB-525-B04.

Il manuale per l’uso completo Kowa, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Kowa RB-525-B04 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Kowa RB-525-B04, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Kowa RB-525-B04 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Kowa RB-525-B04 - che ci dovrebbe aiutare nei primi passi durante l'uso Kowa RB-525-B04
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Kowa RB-525-B04
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Kowa RB-525-B04 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Kowa RB-525-B04?

Utilizza il modulo sottostante

Se non hai risolto il problema con Kowa RB-525-B04 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Kowa RB-525-B04 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)