    Adam Equipment CFW SERIES (P.N. 6162, Revision A5, May 2006) Software Version: V1.04 @Adam Equipment Company 2006 ...

  • Adams CFW 150 - page 2

    @Adam Equipment Company 2006 ...

  • Adams CFW 150 - page 3

    CONTENTS 1.0 INTRODUCTION ............................................................................................................ 3 2.0 SPECIFICATIONS ......................................................................................................... 4 3.0 INSTALLATION ..................................................................... ...

  • Adams CFW 150 - page 4

    @Adam Equipment Company 2006 2 ...

  • Adams CFW 150 - page 5

    1.0 INTRODUCTION • The CFW series of scales provide an accurate, fast, versatile series of general purpose weighing scales with counting and check-weighing functions. • There are 2 series of scales- CF W scales are kilogram only scales and the CFWa scales offer changeable unit from pounds to kilograms. The scales share the same functions but sp ...

  • Adams CFW 150 - page 6

    2.0 SPECIFICA TIONS CFW SERIES Model # CFW 60 CFW 150 CFW 300 CFW 600 Maximum Capacity 60 kg 150 kg 300 kg 600kg Readability 5 g 10 g 20 g 50g Repeatability (Std Dev) 5 g 10 g 20 g 50g Linearity ± 10 g 20 g 40 g 100g Tare Range -60 kg -150 kg -300 kg -600kg Platform Size 425 mm x 525 mm 600 mm x 800 mm Overall Dimensions (w x d x h) 425 mm x 700 m ...

  • Adams CFW 150 - page 7

    Common Specifications Interface RS-232 bi-directional Interface (Optional) Stabilisation Time 2 seconds typical Operating Temperature 0°C - 40°C 32°F - 104°F Power supply 9 VDC, 800 mA from external power supply Internal re-chargeable battery (up to 70 hours operation) Calibration Automatic External Display 1 x 6 digits LCD digital display Bala ...

  • Adams CFW 150 - page 8

    3.0 INST ALLA TION 3.1 LOCATING THE SCALES • The scales should not be placed in a location that will reduce the accuracy. • Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents. • Avoid unsuitable tables. The table or floor must be rigid and not vibrate. • Avoid unstable power sources. Do not use nea ...

  • Adams CFW 150 - page 9

    3.3 SETTING UP THE SCALES • The pillar is attached to the base using a bracket that must be attached to the base frame first using the 4 bolts supplied. The pillar is secured to the bracket using 2 sets of screws. The cable from the base to the indicator module is run through the tube and taken out through the plastic support at the top. Excess c ...

  • Adams CFW 150 - page 10

    4.0 KEY DESCRIPTIONS [Zero] or Sets the zero point for all subsequent weighing. The display shows zero. A secondary function is of "Enter" key used when setting up the value for the Parameters. [Tare] or Tares the scale. Stores the weight currently on the scale as tare value, subtracts the tare value from the gross weight and shows the re ...

  • Adams CFW 150 - page 11

    A secondary function is to move the active/flashing digit to the right when setting values for the Parameters. [Func] or [F] Selects the Functions of the scale. If the scale is weighing, it will select parts counting. If it is not in weighing mode, it will return the user to weighing. A secondary function ( C ) is to act as a clear key when setting ...

  • Adams CFW 150 - page 12

    6.0 OPERA TION 6.1 ZEROING THE DISPLAY • You can press the [Zero/Enter] key at any time to set the zero point. This will usually be necessary when the platform is empty. When the zero point is obtained the display will show an indicator for zero. • The scale has an automatic re-zeroing function to account for minor drifting or accumulation of m ...

  • Adams CFW 150 - page 13

    tared a second time if another type of product was to be added to the first one. Again only the weight that is added after taring will be displayed. • When the container is removed a negat ive value will be shown. If the scale was tared just before removing the container this value is the gross weight of the container plus all products that was r ...

  • Adams CFW 150 - page 14

    • Press the [Zero/Enter] key again when the number matches the number of parts used as the sample. As more weight is added the display will show the number of parts (pcs). • Pressing the [Pcs] key will display the unit weight (g/pcs), pressing it second time will display the net weight (pcs and kg) and the third time, it will be the count again ...

  • Adams CFW 150 - page 15

    6.5 CHECK-WEIGHING Check-weighing is a procedure to cause an alarm to sound when the weight on the scale meets or exceeds values st ored in memory. The memory holds values for a high and a low limit. Either or both can be used. See PARAMETERS Section for the procedure. To set the limits, " F0 H-L " is used. After limits have been set the ...

  • Adams CFW 150 - page 16

    Checkweighing facility can be set up during Weighing or Parts Counting by entering values as Low or/and High Limits keyed in by the user. The limits are displayed in kg or pcs respectively. Checkw eighing during Weighing Checkw eighing during Parts Counting To disable the Check-Weighing function enter zero into both limits by pressing the [Func/C] ...

  • Adams CFW 150 - page 17

    • Remove the weight, allowing the scale to return to zero and put a second weight on. Press the [Print/M+] key, the display will show " ACC 2 ", then the new total and finally the value of the second weight. No. of accumulation of w eights Total w eight for 3 accumulations • Continue until all weights have been added. • To view the ...

  • Adams CFW 150 - page 18

    7.0 USER P ARAMETERS • The scale has 7 User Parameters that can be set by the user. To set these Parameters press the [Func] key. The display will show the first parameter, " F0 H-L ". • Pressing the [Tare/ Ï ] will cycle through the other parameters. • Pressing [Zero/Enter] will allow you to enter a parameter directly for setting ...

  • Adams CFW 150 - page 19

    SETTING OF USER PARAMETERS PARAMETER SUB- PARAMETER DESCRIPTION DEFAULT VALUE SEt Lo Sets a value for the Low Limit used for checkweighing. 000.000 F0 H-L SEt HI Sets a value for the High Limit for checkweighing. 000.000 to CLr Clears the Accumulation Total in the memory without printing the results. to P-C Prints the Accumulation Total in the memo ...

  • Adams CFW 150 - page 20

    F5 Prt Sets the RS-232 - P bAUd- Select from the desired baud rates. Options are 600, 1200, 2400, 4800 and 9600 P nodE - Set the printing mode to- P Prt (Print only when [Print] is pressed) P Cont (Print continuously) P Auto (Print automatically whenever there is any weight on the scale). Parity – Select from the following settings- n 8 1 - 8 dat ...

  • Adams CFW 150 - page 21

    8.0 BA TTER Y OPERA TION • The scales can be operated from the batt ery if desired. The battery life is approximately 70 hours. • When the battery needs charging a symbol on the display will turn on. The battery should be charged when the symbol is on. The scale will still operate for about 10 hours after which it will automatically switch off ...

  • Adams CFW 150 - page 22

    9.0 RS-232 INTERF ACE The CFW Series of scales can be ordered with an optional RS-232 bi-directional interface. Specifications: RS-232 output of weighing data ASCII code 4800 Baud (600-9600 selectable) 8 data bits (8 data bits no parity, 7 data bits even and odd parity selectable) No Parity Connector: 9 pin d-subminiature socket Pin 2 Input Pin 3 O ...

  • Adams CFW 150 - page 23

    When parts counting- the weight, unit w eight and count w ill be printed: GS 12.340kg GS for Gross we ight, NT for net weight and a unit of weight UW 123.4g The average piece weight computed by the scale PCS 100pcs The number of parts counted <lf> Includes 2 line feeds <lf> When recalling the Total weight stored in the accumulation memo ...

  • Adams CFW 150 - page 24

    10.0 CALIBRA TION The scale can be calibrated using the fo llowing procedure. For a more detailed method of calibrating the scale, it will be necessary to enter the secure Programming Menu. Refer to the CFW Service Manual for more information. The CFW scales calibrate using eit her metric or pound weights, depending on the weighing unit in use befo ...

  • Adams CFW 150 - page 25

    1 1.0 SER VICE SECTION To set the Service Parameters it will be necessary to enter the User Parameters as before and then use a password code while entering the programming parameter “ PROG ”. 11.1 CFW FACTORY PROGRAMMING AND CALIBRATIONS • The parameter “ PROG ” allows access to the calibration section. To enter this parameter press [Fun ...

  • Adams CFW 150 - page 26

    SETTING OF SERVICE PARAMETERS SUB- PARAMETER FUNCTIONS DESCRIPTION DEFAULT SETTING AZn 0 Auto Zero operating range. (Options: 0.5d, 1.0d, 2d, 4d) Sets the operational range of the auto zero function. 1d 0-Auto Initial Zero range at power on. (Options: 0%, 2%, 5%, 10% and 20%) Sets the range for setting a zero when power is applied. The total capaci ...

  • Adams CFW 150 - page 27

    dEC1 Selects the decimal point position (Options: 0, 0.0, 0.00, 0.000). C 0.00 InC Selects the increment size. (Options: 1, 2, 5 and 10). inC 10 CAP Sets the scale capacity. The maximum value for the scale is as specified for the scale. For example 60kg. P2 CAL CAL Starts the calibration procedure. See the details of calibration procedure in sectio ...

  • Adams CFW 150 - page 28

    12.0 ERROR CODES ERROR CODES DESCRIPTION SUGGESTIONS - -oL - - Over-range Remove weight from the scale. If the problem persists contac t your dealer or Adam Equipment for assistance. Err 1 Date Setting Error Enter date using correct format and reasonable values. Format: yy:mm:dd Err 2 Time Setting Error Enter time using correct fo rmat and reasonab ...

  • Adams CFW 150 - page 29

    13.0 REPLACEMENT P ARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact y our supplier or Adam Equipment. A partial list of such items is as follows- • Power Supply Module • Main Power cord • Replacement Battery • Stainless Steel Pan • In use cover • RS-232 option • Printer, etc. 14.0 SER VICE INFORMA TIO ...

  • Adams CFW 150 - page 30

    WARRANTY INFORMATION Adam Equipment offers Limited Wa rranty (Parts and Labour) for the components failed due to defects in ma terials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equi pment Company. The company or its authorise ...

  • Adams CFW 150 - page 31

    Manufacturer’s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards, following the provisions of the below stated directives: Electro Magnetic Compatibility Directive 89/336/EEC Low Voltage Directive 73/23/EEC Adam Equipment Co. Ltd. Bond Avenue Denbigh East Estate Milton Keynes, MK1 1S ...

  • Adams CFW 150 - page 32

    @Adam Equipment Company 2006 ADAM EQUIPMENT is an ISO 9001:2000 certified global organisation with more than 30 years experience in the producti on and sale of electronic weighing equipments. Products are sold through a world wide distributor network -supported from our com pany locations in the UK, USA, SOUTH AFRICA and CHINA. The company and thei ...

Fabbricante Adams Categoria Building Set

I documenti che otteniamo dal fabbricante del dispositivoAdams CFW 150 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Adams
- manuali per l’uso CFW 150
- schede prodotto Adams
- opuscoli
- o etichette energetiche Adams CFW 150
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Adams CFW 150.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Adams CFW 150, manuali di manutenzione, brevi manuali o manuali utente Adams CFW 150. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Adams CFW 150.

Manuali per l’uso simili

Manuale completo del dispositivo Adams CFW 150, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Adams CFW 150 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Adams CFW 150.

Il manuale per l’uso completo Adams, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Adams CFW 150 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Adams CFW 150, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Adams CFW 150 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Adams CFW 150 - che ci dovrebbe aiutare nei primi passi durante l'uso Adams CFW 150
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Adams CFW 150
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Adams CFW 150 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Adams CFW 150?

Utilizza il modulo sottostante

Se non hai risolto il problema con Adams CFW 150 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Adams CFW 150 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)