  • Bunn CDBC-MV - page 1

    OPERA TING & SER VICE MANU AL CDBC-DV , CDBCF-DV CDBC-DV , CDBCF APS-DV CDBCF LPTC-DV CDBC-MV , CDBCF-MV CDBC-MV , CDBCF APS-MV B U N N M A N U F A C T U R E D B Y B U N N - O - M A T I C C O R P O R A T I O N S P R I N G F I E L D , I L L I N O I S , U . S . A . M O D E L S / N V O L T S A . C . A M P W A T T S P H A S E W I R E H E R T Z C O ...

  • Bunn CDBC-MV - page 2

    Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for 120V 15 amp, 120V 20 amp (MV models only), 120/208V 20 amp or 120/240V 20 amp. The brewer may have a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf. BUNN-O-MATIC COM ...

  • Bunn CDBC-MV - page 3

    Page 3 #00658.0000 #00831.0000 #29710.0000 (MV models only) THREE WARMER BREWERS Optional Field Wiring 120 V , 17.0 A, 2050 W 1PH, 2-Wire, 60HZ or 120/208-240 V , 13.6-15.3 A, 2640-3430 W 1PH, 3-Wire, 60HZ #29710.0002 (MV models only) TWO WARMER BREWERS Optional Field Wiring 120 V , 18.0 A, 2150 W 1PH, 2-Wire, 60HZ or 120/208-240 V , 14.4-16.2 A, 2 ...

  • Bunn CDBC-MV - page 4

    Page 4 USER NOTICES (CONT .) #29710.0005 (DV models only) CDBCF-DV BREWERS Optional Field Wiring 120 V , 15.0 A, 1800 W 1PH, 2-Wire, 60HZ Optional Field Wiring 120/208-240 V , 15.6-17.5 A, 2980-3850 W 1PH, 3-Wire, 60HZ Optional Field Wiring 120/208-240 V , 13.0-15.0 A, 2680-3550 W 1PH, 3-Wire, 60HZ #29710.0008 (DV models only) CDBC LPTC-DV BREWERS ...

  • Bunn CDBC-MV - page 5

    Page 5 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Requires 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. 1425W VERSION 3180W VERSION Requires 3-wire, grounded service rated 120/240 volts ac, 20 amp, single phase, 60 Hz. ELECTRICAL HOOK-UP CAU ...

  • Bunn CDBC-MV - page 6

    Page 6 29707 112801 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Requires 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. Requires 2-wire, grounded service rated 120 volts ac, 20 amp, single phase, 60 Hz. ELECTRICAL HOOK-UP CAUTION – Improper e ...

  • Bunn CDBC-MV - page 7

    Page 7 INITIAL SET -UP 1. Insert an empty funnel into the funnel rails. 2. Place a decanter with a small amount of water under the funnel. 3. Connect the brewer to the power source. 4. Press the "ON/OFF" switch (indicator glowing). 5. Water will flow into the tank and stop when the tank is filled to its capacity. 6. Wait approximately twe ...

  • Bunn CDBC-MV - page 8

    Page 8 OPERA TING CONTROLS ON/OFF SWITCH Pressing the "ON/OFF" switch (indicator glowing) supplies power to the brew station warmer, enables the brew circuit, and energizes the tank refill circuit. Pressing the switch again (indicator not glowing) stops tank refilling and brewing and de-energizes the brew station warmer. Stopping a brew c ...

  • Bunn CDBC-MV - page 9

    Page 9 ADJUSTMENTS & OPTIONAL SETTINGS HIDDEN SWITCH Setting Brew Temperature The brewer is factory set to brew at 200 ° F (95 ° C). To change this setting, press and hold the "HIDDEN" switch beneath the "®". The word "TEMP" above the "ON/OFF" switch will glow to correspond with the temporary function ...

  • Bunn CDBC-MV - page 10

    Page 10 3. Press and hold the brew start button until you hear the brew solenoid click on-and-off three times (approximately 5 seconds). Release the button. 4. Allow the cycle to continue until the desired amount of water is dispensed and then turn "OFF" the brewer. The brewer is now set to dispense this amount of water for each subsequen ...

  • Bunn CDBC-MV - page 11

    Page 11 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only b ...

  • Bunn CDBC-MV - page 12

    Page 12 Will not fill or refill PROBABLE CAUSE REMEDY PROBLEM 1. Power off to brewer 2. Water shut off 3. Display flashing 4. ON/OFF Switch 5. Lime build up on Probe 6. Refill Valve or Control Board Press warmer switches on control panel to determine if power is ON. Make sure water is ON. Brewer has shut down due to mal- function (See Diagnostic Ch ...

  • Bunn CDBC-MV - page 13

    Page 13 TROUBLESHOOTING (cont.) Fill or refill does not shut "OFF" (ON/ OFF Switch "ON") Fill or refill does not shut "OFF" (ON/ OFF Switch "OFF") PROBABLE CAUSE REMEDY PROBLEM 1. Lime build up on probe 2. Water Level Probe Sensing Sys- tem 3. Refill valve or control board 1. Refill valve or control board Rem ...

  • Bunn CDBC-MV - page 14

    Page 14 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY HEATING CIRCUIT 1. Display flashing 2. Water not touching temperature probe 3. Water Level Probe Sensing Sys- tem 4. Temperature Probe 5. Limit Thermostat Brewer has shut down due to mal- function (See Diagnostic Chart in manual, Page 20, or under top lid). Remove temperature probe and g ...

  • Bunn CDBC-MV - page 15

    Page 15 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Water does not heat to proper tem- perature (cont.) IMPORTANT: Make sure no tem- perature tests are taken before the ready light is "ON". Tank tempera- ture must be stabilized before read- ings are taken. 6. Tank Heater 7. Fuse Holder & Fuse (MV models only) 8. Thermal Fuse ...

  • Bunn CDBC-MV - page 16

    Page 16 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming (cont.) Brewer is making unusual noises 1. Lime build up on temperature probe, tank or tank heater 2. Temperature Probe 3. Control Board 1. Plumbing lines 2. Water supply 3. Lime build up Inspect probe and tank assembly for excessive lime deposits. Delime a ...

  • Bunn CDBC-MV - page 17

    Page 17 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT Brew cycle will not start 1. Display flashing 2. No water 3. No power or incorrect voltage to the brewer 4. ON/OFF switch not in the "ON" position 5. Low water temperature (Brew lockout is enabled) 6. Water not touching refill probe inside tank 7. Switch panel B ...

  • Bunn CDBC-MV - page 18

    Page 18 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) If the switch panel is operating prop- erly, proceed as follows. Attach a voltmeter to the terminals of the dispense solenoid. Connect the brewer to the power source. Turn on the brewer and press the BREW switch. Voltage should be present at the solenoid terminals ...

  • Bunn CDBC-MV - page 19

    Page 19 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) Dripping from sprayhead Weak beverage 1. Lime build up 2. Dispense valve 1. Sprayhead 2. Water temperature 3. Filter type 4. Coffee grind 5. Funnel loading Inspect the tank assembly for ex- cessive lime deposits. Delime as required. Remove the dispense valve and c ...

  • Bunn CDBC-MV - page 20

    Page 20 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) Dry coffee grounds remain in the funnel Low beverage serving temperature 1. Sprayhead 2. Funnel loading 1. Warmer Make sure sprayhead is present and holes are clear and unobstructed. There should be six separate streams of water coming out of the sprayhead. The BU ...

  • Bunn CDBC-MV - page 21

    Page 21 Intermittent flashing of the bank of temperature indicators, indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to investigating the fault. FLASHES CAUSE THINGS TO CHECK 1 Dry Plug - In Fault - Water Pressure (Is water shut "OFF"?) Sheath of temperature probe dry for 10 minutes ...

  • Bunn CDBC-MV - page 22

    Page 22 C A U T IO N : W A R M E R S A N D S U R F A C E S A R E H O T C A U T I O N D IS C A R D D E C A N T E R IF : ! BUNN M A N U F A C T U R E D B Y B U N N - O - M A T I C C O R P O R A T I O N S P R I N G F I E L D , I L L IN O I S , U . S . A . M O D E L S /N V O L T S A .C . A M P W A T T S P H A S E W I R E H E R T Z C O V E R E D U N D E ...

  • Bunn CDBC-MV - page 23

    Page 23 SERVICE (cont.) CONTROL BOARD Location: The Control Board is located inside the top cover behind the front end cap. Test Procedures: The test procedures for the control board will vary depending upon the problems experienced by the brewer. Refer to the Troubleshooting guide beginning on page 10. The troubleshooting guide is divided into thr ...

  • Bunn CDBC-MV - page 24

    Page 24 SERVICE (cont.) SWITCH PANEL Location: The Switch Panel is located in the front of the hood. Test Procedures: The test procedures for the switch panel and the control board will vary depending upon the problems experienced by the brewer. Refer to the Troubleshoot- ing guide beginning on page 10. The troubleshooting guide is divided into thr ...

  • Bunn CDBC-MV - page 25

    Page 25 SERVICE (cont.) DISPENSE VALVE Location: The dispense valve is located inside the top cover behind the front end cap. Test Procedures: 1. Disconnect the brewer from the power source. 2. Check the water level in the tank to confirm that it is within 1/2" from the top of the tank. 3. Connect the brewer to the power source. If the brewer ...

  • Bunn CDBC-MV - page 26

    Page 26 C A U T IO N : W ARME RS AN D SU RFACES ARE HO T ...

  • Bunn CDBC-MV - page 27

    Page 27 All models Removal and Replacement: 1. Remove the top cover or top warmer housing and front access panel as previously described. 2. Disconnect the vent hose from the top of the tank by pulling the elbow fitting from the grommet in the top of the tank lid. 3. Drain water from the tank. 4. Disconnect the water supply tube to the dispense val ...

  • Bunn CDBC-MV - page 28

    Page 28 29707 012502 11. Disconnect the two white wires from the tank warmer blanket. 12. Disconnect the black, white and blue wires from the tank heater terminals. DV models only, dis- connect the brown and red wires from tank heater terminals. 13. Remove the four #8-32 nuts securing the tank to the mounting brackets and remove the tank as- sembly ...

  • Bunn CDBC-MV - page 29

    Page 29 C A U T I O N : WARMERS AND SURFACES ARE HOT ...

  • Bunn CDBC-MV - page 30

    Page 30 SERVICE (cont.) REFILL VALVE Location: The refill valve is located inside the trunk on the lower center part of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the white and white/blue wires from the refill valve. Set the "ON/OFF" switch in the "ON" upper position. 3. ...

  • Bunn CDBC-MV - page 31

    Page 31 C A U T I O N D I S C A R D D E C A N T E R IF : ! Location: The warmer element(s) is located under the warmer plate. Test Procedures: 1. Disconnect the brewer from the power source. 2. With a voltmeter, check voltage across the two wires at the warmer element with the "ON/OFF" switch in the "ON" position. Connect the br ...

  • Bunn CDBC-MV - page 32

    Page 32 C A U T IO N : W ARMERS AND SU RFACES ARE HOT ...

  • Bunn CDBC-MV - page 33

    Page 33 ...

  • Bunn CDBC-MV - page 34

    Page 34 P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR. SOL SCHEMATIC WIRING DIAGRAM CDBC DV 29685.0002D 05/02 ©2001 BUNN-O-MATIC CORPORATION P2 P1 P1 FRONT WARMER P3 BRN/BLK VIO WHI REAR WARMER L1 BLU-14 BLU-14 "KEEP WARM" HEATER BREW STATION WARMER (CONTROLLED BY ON/OFF SW) LIMIT THERMOSTAT BRN/BLK VIO P2 P3 WHI/RED WHI/R ...

  • Bunn CDBC-MV - page 35

    Page 35 SOL SCHEMATIC WIRING DIAGRAM CDBC APS-DV CDBCF APS/TC/LPTC-DV 29685.0003E 08/03 ©2001 BUNN-O-MATIC CORPORATION L1 BLU-14 BLU-14 "KEEP WARM" HEATER LIMIT THERMOSTAT WHI WHI WHI WHI WHI SOL REFILL DISPENSE J1-1 J1-2 J1-1 J1-5 J1-10 C O N T R O L P C B O A R D COM N.O. BLK BLK BLK-14 BLK-14 BLK-14 BLK WHI/GRN WHI/GRN WHI/BLU WHI/BLU ...

  • Bunn CDBC-MV - page 36

    Page 36 P1, P2, & P3 ARE PINS OF A POLARIZED THREE-PIN CONNECTOR. SOL SCHEMATIC WIRING DIAGRAM CDBC MV 29685.0000A 4/99 ©1999 BUNN-O-MATIC CORPORATION P2 P1 P1 FRONT WARMER P3 BRN/BLK VIO WHI REAR WARMER L1 BLU-14 BLU-14 "KEEP WARM" HEATER BREW STATION WARMER (CONTROLLED BY ON/OFF SW) LIMIT THERMOSTAT BRN/BLK VIO P2 P3 WHI/RED WHI/RE ...

  • Bunn CDBC-MV - page 37

    Page 37 SOL SCHEMATIC WIRING DIAGRAM CDBC - APS MV 29685.0001A 4/99 ©1999 BUNN-O-MATIC CORPORATION L1 GRN BLU-14 BLU-14 "KEEP WARM" HEATER WHI WHI WHI LIMIT THERMOSTAT WHI WHI WHI SOL REFILL DISPENSE J1-1 J1-2 J1-1 J1-5 J1-10 C O N T R O L P C B O A R D COM N.O. BLK BLK BLK BLK-14 BLK WHI/GRN WHI/GRN WHI/BLU WHI/BLU COUNTER (OPTIONAL) 12 ...

Fabbricante Bunn Categoria Coffeemaker

I documenti che otteniamo dal fabbricante del dispositivoBunn CDBC-MV possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bunn
- manuali per l’uso CDBC-MV
- schede prodotto Bunn
- opuscoli
- o etichette energetiche Bunn CDBC-MV
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bunn CDBC-MV.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bunn CDBC-MV, manuali di manutenzione, brevi manuali o manuali utente Bunn CDBC-MV. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bunn CDBC-MV.

Manuali per l’uso simili

Manuale completo del dispositivo Bunn CDBC-MV, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bunn CDBC-MV dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bunn CDBC-MV.

Il manuale per l’uso completo Bunn, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bunn CDBC-MV - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bunn CDBC-MV, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bunn CDBC-MV che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bunn CDBC-MV - che ci dovrebbe aiutare nei primi passi durante l'uso Bunn CDBC-MV
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bunn CDBC-MV
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bunn CDBC-MV in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bunn CDBC-MV?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bunn CDBC-MV con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bunn CDBC-MV è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)