Manuale per l’uso RIDGID OL90150

28 pagine 1.41 mb
Scarica

Vai alla pagina of 28

Summary
  • RIDGID OL90150 - page 1

    OL90150 OPERA TOR’S MANUAL WHEELBARROW AIR COMPRESSOR T o reduce the risk of injury , the user must read and under stand the Operator’ s Manual before using this product. ! WARNING: IN614300A V 9/04 Printed in U.S.A. ...

  • RIDGID OL90150 - page 2

    T able of Contents Section P age T able of Contents . . . . . . . . . . . . . . . .2 Safety Instructions . . . . . . . . . . . . . . .3 Safety Signal Words . . . . . . . . . . . . .3 Before Using the Air Compressor . . . . . . . . . . . . . . . . . . . .3 Spraying Precautions . . . . . . . . . . . .5 Breathable Air W arning . . . . . . . . . . .5 W ...

  • RIDGID OL90150 - page 3

    Safety Instructions This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROB- LEMS. T o help recognize this informa- tion, observe the following symbols. Safety Signal W or ds Danger indicates an imminently haz- ardous situation which, if not avoided, WILL ...

  • RIDGID OL90150 - page 4

    8. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). 9. Wiring and fuses should follow electri- cal codes, current capacity , and be properly grounded. 10. Electric motors must be securely and adequately grounded. See grounding instructions and extension co ...

  • RIDGID OL90150 - page 5

    1. Do not smoke when spraying paint, insecticides, or other flammable sub- stances. 2. Use a face mask/respira- tor when spraying and spray in a well ventilated area to prevent health and fire hazards. 3. Do not direct paint or other sprayed material at the compressor . Locate compressor as far away from the spraying area as possible to minimize ov ...

  • RIDGID OL90150 - page 6

    Safety Instructions (contin ued) 6 Find and read all warning labels found on the air compressor shown below W arning Labels DK724100AV 100 0 ...

  • RIDGID OL90150 - page 7

    The A-C motor used on this compressor is a capacitor start, capacitor run non- reversible induction type, having the fol- lowing specifications. It is wired at the factory for operation on 1 10V -120V AC, 60 Hz service. V oltage 1 10-120 220-240 Amperes 15.0 7.5 Hertz (Cycles) 60 Phase Single RPM 3450 Motor Specifications and Electrical Requirement ...

  • RIDGID OL90150 - page 8

    8 The plug supplied on your tool may not fit into the outlet you are planning to use. Y our local electrical code may require slightly different power cord plug connec- tions. If these differences exist refer to and make the proper adjustments per you local code before your tool is plugged in and turned on. In the event of a malfunction or break- d ...

  • RIDGID OL90150 - page 9

    9 NOTE: The motor is prewired at the fac- tory for 120V operation. Use the follow- ing procedure to change motor voltage to 240V . 1. Unplug the power cord before making or modifying connections. 2. Remove the hitch pin. 3. T oggle the motor voltage selector switch from 120V to 240V . 4. Install the hitch pin. 5. Unscrew the pressure switch cover r ...

  • RIDGID OL90150 - page 10

    10 Thermal Overload Protector If thermal overload protector shuts motor OFF frequently look for the following causes. 1. Low voltage. 2. Wrong gauge wire. 3. Clogged air filter . 4. Lack of proper ventilation. 5. Unit is being used with an extension cord. See T roubleshooting Chart for corrective action. This compressor is equipped with an automati ...

  • RIDGID OL90150 - page 11

    11 Regulator A control that adjusts the line pressure to the proper amount needed to operate spray guns and air tools. T ank Pressure Gauge Indicates tank pressure in psi. Line Pressure Gauge Displays the current line pressures. It is regulated by the regulator knob. Cut-in/Cut-off Pressure Specific psi at which a compressor starts and stops while ...

  • RIDGID OL90150 - page 12

    12 Getting to Know Y our Air Compressor 2 Air Filter 5 T ank Drain V alve 4 Handles 1 Belt Guard 3 Dipstick 7 Air Storage T ank 6 On/Off Switch (Pressure Switch) 12 ASME Safety V alve 10 Regulator Knob 13 Air Outlet Fittings 11 T ank Pressure Gauge 9 Regulated Outlet Gauge 8 Motor V oltage Selector Switch ...

  • RIDGID OL90150 - page 13

    13 1. Belt Guard. The belt guard encloses the pulleys and drive belt. It protects the user from moving parts and directs cooling air to the compressor pump. 2. Air Filter . The air filter keeps dirt and debris from entering the compressor pump and reduces compressor noise. 3. Dipstick. The dipstick measures the oil level in the compressor pump. 4. ...

  • RIDGID OL90150 - page 14

    14 Operating Y our Air Compressor All lubricated compressor pumps dis- charge some condensed water and oil with the compressed air . Install appropri- ate water/oil removal equipment and con- trols as necessary for the intended appli- cation. Remove the dipstick and fill pump with 12 ounces of oil. Use single viscosity , ISO 100 (SAE 30), non-deter ...

  • RIDGID OL90150 - page 15

    15 1. Remove the dipstick and fill pump to the proper oil level. See Lubrication Section. 2. Open tank drain valves and turn regu- lator knob counterclockwise. 3. T urn pressure switch knob to OFF position and plug in power cord. 4. Follow this step only if using your compressor for the first time. Tu r n pressure switch knob to AUTO posi- tion and ...

  • RIDGID OL90150 - page 16

    16 Operating Y our Air Compressor (continued) 1. Read instructions: Carefully read through this operator ’s manual BEFORE OPERA TING the new air compressor . It contains information about operation and maintenance of the unit. 2. Drain tanks daily: Depressurize sys- tem prior to draining tanks. Open tank drain valves and drain moisture from tanks ...

  • RIDGID OL90150 - page 17

    17 1. Check compressor for any visible problems, especially check air filter to be sure it is clean. 2. Pull ring on safety valve and allow it to snap back to normal position. 3. Drain moisture from tanks daily . Shut compressor off. Depressurize system prior to draining tanks. Drain moisture from tanks by opening the tank drain valves underneath t ...

  • RIDGID OL90150 - page 18

    18 The tanks should be carefully inspected at a minimum of once a year . Look for cracks forming near the welds. If a crack is detected, remove pressure from tank immediately and replace. Ta n k Never attempt to repair or modi- fy a tank! W elding, drilling or any other modification will weaken the tank resulting in damage from rupture or e xplo- s ...

  • RIDGID OL90150 - page 19

    19 Operation Daily Weekly Drain T anks  Check Air Filter  Check Safety V alve  Blow Dirt From Inside Motor  Maintenance Schedule 1. When not in use, compressor should be stored in a cool dry place. 2. T anks should be drained of moisture. 3. Hose should be disconnected and hung open ends down to allow any moisture to drain. Storage 2. W ...

  • RIDGID OL90150 - page 20

    20 T roub leshooting For your o wn safety do not try and run the air compressor while troub leshooting. ! WARNING: TROUBLE PROB ABLE CA USE REMED Y Compressor will not run Motor hums but can- not run or runs slow- ly Fuses blow/circuit breaker trips repeat- edly 1. Unit is plugged into extension cord 2. No electrical power 3. Blown fuse 4. Breaker ...

  • RIDGID OL90150 - page 21

    21 TROUBLE PROB ABLE CA USE REMED Y Thermal overload protector cuts out repeatedly Air tank pressure drops when com- pressor shuts off Excessive moisture in discharge air Compressor runs continuously Compressor vibrates Air output lower than normal 1. Low voltage 2. Clogged air filter 3. Lack of proper ventila- tion/room temperature too high 4. Uni ...

  • RIDGID OL90150 - page 22

    22 TROUBLE PROB ABLE CA USE REMED Y Low discharge pres- sure 1. Air leaks 2. Leaking valves 3. Restricted air intake 4. Slipping belts 5. Blown gaskets 6. Low compression 1. Listen for escaping air . Apply soap solution to all fittings and connections. Bubbles will appear at points of leakage. T ighten or replace leaking fittings or connections 2. ...

  • RIDGID OL90150 - page 23

    23 TROUBLE PROB ABLE CA USE REMED Y Excessive belt wear Oil in the discharge air 1. Pulley out of alignment 2. Belt too loose or too tight 3. Belt slipping 4. Pulley wobbles 1. Worn piston rings 2. Compressor air intake restricted 3. Restricted breather 4. Excessive oil in compres- sor 5. Wrong oil viscosity 6. Connecting rod out of alignment 1. Re ...

  • RIDGID OL90150 - page 24

    24 Repair P arts 1 2 3 4 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 32 33 34 35 39 40 41 42 43 9 8 7 6 T o pump 37 30 31 ...

  • RIDGID OL90150 - page 25

    25 Repair P arts For Repair P arts, Call 1-800-4-RIDGID Please provide f ollowing inf ormation: -Model number -Serial number (if any) -Part description and number as shown in parts list Ref. Catalog Part No. Number Number Description Qty 1 20353 AR054700CG T ank 1 2 17853 ST158300A V Rubber Foot 4 3 18038 ST116400A V Screw 4 4 20358 ST085800A V Dra ...

  • RIDGID OL90150 - page 26

    26 Repair P arts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 23 ...

  • RIDGID OL90150 - page 27

    27 Ref. Catalog Part No. Number Number Description Qty 1 18143 VT040300AG Crankcase 1 2—  Crankcase gasket 1 3 18133 VT041700AJ Dipstick breather 1 4 18128 VT040750AG Cylinder 1 5—  Cylinder gasket 1 6 18158 VT040100AG Connecting rod 2 7 18163 VS001400A V Piston pin 2 8 18148 ST084202A V Ball bearing 2 9 18153 VT040600AJ Crankshaft Assemb ...

  • RIDGID OL90150 - page 28

    © 2004 RIDGID , INC. Part No. IN614300A V 9/04 Form No. IN614300A V Printed in U.S.A. 9/04 RIDGID AIR COMPRESSOR LIMITED THREE YEAR W ARRANTY This product is manufactured by Campbell Hausfeld. The trademark is licensed from RIDGID, Inc. All warranty communications should be directed to RIDGID air com- pressor technical service at (toll free) 1-800 ...

Fabbricante RIDGID Categoria Air Compressor

I documenti che otteniamo dal fabbricante del dispositivoRIDGID OL90150 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici RIDGID
- manuali per l’uso OL90150
- schede prodotto RIDGID
- opuscoli
- o etichette energetiche RIDGID OL90150
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso RIDGID OL90150.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione RIDGID OL90150, manuali di manutenzione, brevi manuali o manuali utente RIDGID OL90150. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto RIDGID OL90150.

Manuali per l’uso simili

Manuale completo del dispositivo RIDGID OL90150, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare RIDGID OL90150 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti RIDGID OL90150.

Il manuale per l’uso completo RIDGID, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale RIDGID OL90150 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice RIDGID OL90150, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per RIDGID OL90150 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo RIDGID OL90150 - che ci dovrebbe aiutare nei primi passi durante l'uso RIDGID OL90150
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del RIDGID OL90150
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio RIDGID OL90150 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su RIDGID OL90150?

Utilizza il modulo sottostante

Se non hai risolto il problema con RIDGID OL90150 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con RIDGID OL90150 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)