Manuale per l’uso Windsor D250(115V) 10070100

25 pagine 0.45 mb
Scarica

Vai alla pagina of 25

Summary
  • Windsor D250(115V) 10070100 - page 1

    Read these instructions bef ore operating the machine MOD EL: D250 (115V) 10070100 Beginning with Serial No. 1000054537 86038570 05/11/07 PRV NO. 98828 AB CARPET EXTRACTOR Operating Instru ctions (ENG ) ...

  • Windsor D250(115V) 10070100 - page 2

    TABLE OF CONTENTS D-250 86038570 05/11/07 1 Data Log/Table of Contents .................... 1 Safety Instructions ................................... 2 Grounding Instructions ............................ 3 Operations ............................................... 4 Maintenance …………………………. ..... 6-9 Troubleshooting ............. ...

  • Windsor D250(115V) 10070100 - page 3

    SAFETY INSTRUCTIONS D-250 86038570 05/11/07 2 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded ...

  • Windsor D250(115V) 10070100 - page 4

    GROUNDING INSTRUCTIONS NOTE: In Can ada, th e use o f a tem p orary adaptor i s no t p ermit te d by the C anadia n Electri cal Co de PROPER GR OUND ING (115V) Meta l Sc r e w A daptor Grounded Out let Box Fig. A Fig. B Fig. C Tab For Gr ounding S crew Grounded Outlet Grounding P in A dapto r THIS PRODUCT IS FOR COMMERCI AL USE ONLY. ELECTRICAL: Th ...

  • Windsor D250(115V) 10070100 - page 5

    OPERATIONS D-250 86038570 05/11/07 4 CARPET INSPECTION: Determine precisely what areas you a re going to clean. Note problem areas in the carpe t or tack strip. Look for loose carpet, heavily damaged a rea s, discolored stains, or grease spots that will require prespotting. Note the carpet type. Check the availability of hot water, drains, and suit ...

  • Windsor D250(115V) 10070100 - page 6

    OPERATION D-250 86038570 05/11/07 5 HEATER OPERATION The disconnect fittings o n the heater will become extremely hot during operation. Allow sufficient time to cool, or run solution through the machine with the heater turned off before disconn ecting the or performing any maintenance on the h eater. Before disconnecting the heater, ope n wand valv ...

  • Windsor D250(115V) 10070100 - page 7

    MAINTENANCE D-250 86038570 05/11/07 6 DAILY MAINTENANCE: (At the end of each working day): 1. Flush the entire system, including floor t ool, hand tool, etc., with 1 to 3 gallons of clean, hot water. 2. Vacuum out the solution tank . 3. Rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospi ...

  • Windsor D250(115V) 10070100 - page 8

    MAINTENANCE D-250 86038570 05/11/07 7 SERVICE SCHEDULE MAINTENANCE DAILY WEEKLY QUARTERLY Check machine for cord damage * Check recovery dome an d gasket for damage and cleanliness * Check hose s f or wear, bloc kag es, or damage * Check handles, swit ches, and knob s for damage * Check vac motor intake filter and clea n * Run one gallon of water t ...

  • Windsor D250(115V) 10070100 - page 9

    MAINTENANCE D-250 86038570 05/11/07 8 ONLY QUALIFIED MAINTENANCE PE RSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEME NT 1. Turn off all switches and unplug machi ne. 2. Remove recovery tank. 3. Locate the vacuum motor wires and discon nect at the connector. 4. Remove the vacuum motor. 5. Reverse process to install vacuum moto r. ...

  • Windsor D250(115V) 10070100 - page 10

    MAINTENANCE D-250 86038570 05/11/07 9 D-250 PUMP MAINTENA NCE Per manufacturer’s recommendatio ns the following main tena nce should be performed utilizi ng noted kits: 1.) 500 hours-Kit 86201080 – PRV NO. 250 -75A replaces the V-packing, wave washer, pa cking spreader a nd plunger guide. 2.) 500 hours-Kit 86201100 – PRV NO. 250 -75C replaces ...

  • Windsor D250(115V) 10070100 - page 11

    TROUBLESHOOTING D-250 86038570 05/11/07 1 0 TROUBLE SHOOTING CHAR T PROBLEM POSSIBLE CAUSE SOLUTION No power to machine Dead electrical circuit Check building circuit breaker o r fuse box. Electrical shock Faulty power cord Replace. Equipment not grounding Follow grounding instructions exa ctly. Electrical shock Receptacle not grounded Contact an e ...

  • Windsor D250(115V) 10070100 - page 12

    TECHNICAL SPECIFICATIONS D-250 86038570 05/11/07 11 TECHNICAL SPECIFICATIONS ELECTRICAL: 115 V, 60 Hz, 15 Amps per power cable ((D250 ) 230 V, 50 Hz, 15 Amps (D250IE) ELECTRIC VACUUM MOTOR (1) –2/1.25 HP, 2 stage, Waterlift –150” (381cm) SOLUTION PUMP 250 psi, adj. SOLUTION CAPACITY 17 gallons (64.3ltr) RECOVERY CAPACITY 15 gallons (56.75ltr) ...

  • Windsor D250(115V) 10070100 - page 13

    NOTES: D-250 86038570 05/11/07 12 ...

  • Windsor D250(115V) 10070100 - page 14

    RECOVERY TANK ASSEMBLY D-250 86038570 05/11/07 13 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 25 26 27 13 28 13 34 35 36 13 29 35 37 30 31 32 33 ...

  • Windsor D250(115V) 10070100 - page 15

    RECOVERY TANK ASSEMBLY D-250 86038570 05/11/07 14 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86033260 05151 1 TUBE ASM, RECOVERY TANK 2 86242230 500009 1 LABEL, WARNING 3 86002620 260-64A 1 ACCESS CO VER CLEAR 6” W/RIM 4 86275800 70546 6 SCR, 8 X 3/4 PFHT/S BLK ZINC 5 86199840 090-12A 1 FLOAT CA GE ASSY COMPLETE SLIP 6 86033330 ...

  • Windsor D250(115V) 10070100 - page 16

    CONTROL PANEL GROUP D-250 86038570 05/11/07 15 5 4 6 2 18 19 3 9 1 16 11 13 17 10 8 12 14 7 15 ...

  • Windsor D250(115V) 10070100 - page 17

    CONTROL PANEL GROUP D-250 86038570 05/11/07 16 REF PART NO. PRV NO. QTY DESCRI PTION SERIAL NO. FROM NOTES: 1 86199650 070-08 1 FAN 105 CFM AXIAL 2 86090870 61367 1 PANEL ASM, CONT. 3 SW W/HEAT 3 86276290 70621006 4 SCR, #10 X 3/4 PPHST HI-LO BLK 4 86199660 070-08A 1 FAN FINGE R GUARD 5 86273810 70018 1 SCR, 1/4-20 X 1 HHCS SS 6 86256960 72142 3 SW ...

  • Windsor D250(115V) 10070100 - page 18

    VACUUM GROUP (LOWER) D-250 86038570 05/11/07 17 4 6 5 7 3 2 10 11 1 8 9 12 ...

  • Windsor D250(115V) 10070100 - page 19

    VACUUM GROUP (LOWER) D-250 86038570 05/11/07 18 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86274980 70335 1 SCR, 10-32 X 1/2 PHTR GRN/GRND 2 86256480 70813 3 STUD, 14/20 X 3.5 SS 3 86010630 87013 3 WASHER, 1/4 ID X 5/8 OD SS 4 86201970 065-92 3 VAC SPACER 2 1/4 II STAGE 5 86003760 35166 1 GASKET, VAC MTR 6 86090980 360-24A 1 PLAT ...

  • Windsor D250(115V) 10070100 - page 20

    PUMP & HEATER GROUP (200 PSI) D-250 86038570 05/11/07 19 1 2 5 7 6 8 9 10 11 16 15 12 13 14 3 4 ...

  • Windsor D250(115V) 10070100 - page 21

    PUMP & HEATER GROUP (200 PSI) D-250 86038570 05/11/07 20 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86199640 030-16 1 ELBOW, 1/4 NPT STREET LONG 90D 2 86200260 151-50C 1 HOSE, PULSE 47.0 1/4MPT X 1/4 MPT 3 86197370 31017 1 ELBOW, 1/4 FPT X 1/4 FPT INCLUDED IN HEATER ASSEMBLY 4 86005590 56014 1 NIPPLE, 1/4 CLOSE INCLUDED IN HE ...

  • Windsor D250(115V) 10070100 - page 22

    SOLUTION TANK ASSEMBLY D-250 86038570 05/11/07 21 10 11 13 12 14 16 8 7 6 11 25 24 5 4 27 1 26 29 28 2 3 1 11 12 23 17 18 19 15 30 35 16 36 37 12 33 34 32 36 20 22 11 12 9 20 21 39 38 40 40 ...

  • Windsor D250(115V) 10070100 - page 23

    SOLUTION TANK ASSEMBLY D-250 86038570 05/11/07 22 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86201290 280-02 2 RIVET AL. 3/16 X 1/2 CLOSED 2 86201500 260-71 1 SOLUTION COVER D/B 3 86002450 22015 1 COUPLER, 1/4 OD 4 86005590 56014 1 NIPPLE, 1/4 CLOSE 5 86199580 250-35 1 D/B BPR 200 PSI 6 86200250 151-50B 1 HOSE, 42” GRY 3/8 1/4M ...

  • Windsor D250(115V) 10070100 - page 24

    SPARE PARTS D-250 86038570 05/11/07 23 SUGGESTED SPARE PARTS PART NUMBER PRV NO. DESCRIPTION SERIAL NO. FROM 86199890 100-04A FUSE 3 AMP 200 PSI 86199240 250-33A BPR REPAIR KIT PUMPTEC 86201810 130-14I THERMOSTAT W/SPADE LEADS 86201790 130-14C THERMOSTAT RESET 86201150 250-79E PUMPTEC 300/400PSI PUMP KIT 1 86201160 250-79F PUMPTEC 300PSI PUMP KIT 2 ...

  • Windsor D250(115V) 10070100 - page 25

    115V WIRING DIAGRAM D-250 86038570 05/11/07 24 ...

Fabbricante Windsor Categoria Vacuum Cleaner

I documenti che otteniamo dal fabbricante del dispositivoWindsor D250(115V) 10070100 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Windsor
- manuali per l’uso D250(115V) 10070100
- schede prodotto Windsor
- opuscoli
- o etichette energetiche Windsor D250(115V) 10070100
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Windsor D250(115V) 10070100.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Windsor D250(115V) 10070100, manuali di manutenzione, brevi manuali o manuali utente Windsor D250(115V) 10070100. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Windsor D250(115V) 10070100.

Manuale completo del dispositivo Windsor D250(115V) 10070100, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Windsor D250(115V) 10070100 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Windsor D250(115V) 10070100.

Il manuale per l’uso completo Windsor, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Windsor D250(115V) 10070100 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Windsor D250(115V) 10070100, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Windsor D250(115V) 10070100 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Windsor D250(115V) 10070100 - che ci dovrebbe aiutare nei primi passi durante l'uso Windsor D250(115V) 10070100
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Windsor D250(115V) 10070100
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Windsor D250(115V) 10070100 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Windsor D250(115V) 10070100?

Utilizza il modulo sottostante

Se non hai risolto il problema con Windsor D250(115V) 10070100 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Windsor D250(115V) 10070100 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)