    USER GUIDE NI sbRIO-960 x Single-Board RI O OEM Devices This document provides dimensions, pi nouts, connectivity information , and specifications for the National Instruments sbRIO-9601 and sbRIO-9602. The devices are referred to inclusively in this document as the sbRIO-960 x . Caution National Instruments makes no prod uct safety , electromagnet ...

  • National Instruments NI sbRIO-960x - page 2

    NI sbRIO-960x 2 ni.com What Y ou Need to Get Started This section lists the software and ha rdware you need to st art programming the sbRIO-960 x . Software Requirements You need a development compu ter with the following soft ware installed on it. Go to ni.com/info and enter the info code rdsoftw areversion for information about soft ware version ...

  • National Instruments NI sbRIO-960x - page 3

    © National Instruments Corporatio n 3 NI sbRIO- 960x Dimensions This section contains dimensional drawings of the sbRIO devices. For three-dimensional models, go to ni.com/singleboard and look on the Resource tab for the sbRIO device you are using. Note The plated mounting holes are all conn ected to P1, the ground lug. Connect P1 or one of the pl ...

  • National Instruments NI sbRIO-960x - page 4

    NI sbRIO-960x 4 ni.com The following f ig ure sho ws the dimensions of the sbRIO-960 x . Figure 2. sbRIO-960 x Dimensions in Inches (Millimeters) .651 (16.54) 8.200 (208.28) 3.650 (92.71) .000 (0) .000 (0) .775 (19.69) 4.100 (104.14) 7.295 (185.29) 2.237 (56.81) 5.147 (130.72) 8.076 (205.13) 3.691 (93.75) .550 (13.97) .275 (6.99) 2.440 (61.98) 3.52 ...

  • National Instruments NI sbRIO-960x - page 5

    © National Instruments Corporatio n 5 NI sbRIO- 960x Y ou can install up to three board-only C Series I/O modules on the sbRIO-960 x . The following figure sho ws t he dimensions of the sb-RIO-960 x with th ree board-only C Series I/O modules instal led. Figure 3. sbRIO-960 x with C Series Modules, Dime nsions in Inch es (Millimeters) Note T o mai ...

  • National Instruments NI sbRIO-960x - page 6

    NI sbRIO-960x 6 ni.com I/O and Other Connectors on the sbRIO Device The following figure shows the locations of parts on the sbRIO device. Figur e 4. sbRIO-960 x Parts Locator Diagra m 1 J11, Connector for C S e ries Module 2P 5 , 3 . 3 V Digital I/O 3 J10, Connector for C S e ries Module 4P 4 , 3 . 3 V Digital I/O 5 J9 , Connector for C S eries Mo ...

  • National Instruments NI sbRIO-960x - page 7

    © National Instruments Corporatio n 7 NI sbRIO- 960x The following table lists and describes the connectors on sbRIO de vices and lists the part number and manufact urer of each connector . Refer to the manufacturer for information about using and matching these connectors. Table 1. sbRIO Connector Descriptions Connector Description Part Number an ...

  • National Instruments NI sbRIO-960x - page 8

    NI sbRIO-960x 8 ni.com The following f igures sho w the pinouts of the I/O connectors on t he sbRIO devices. Figure 5. Pinout of I/O Connector P2, 3.3 V Digital I/O P or t5/DIOCTL P or t5/DIO9 5V D GND 5V D GND D GND D GND D GND D GND P or t6/DIOCTL D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND P or t5/DI ...

  • National Instruments NI sbRIO-960x - page 9

    © National Instruments Corporatio n 9 NI sbRIO- 960x Figure 6. Pinout of I/O Connector P3, 3.3 V Digital I/O P or t7/DIO4 D GND D GND D GND D GND P or t8/DIOCTL D GND D GND D GND D GND D GND D GND D GND D GND D GND P or t9/DIOCTL D GND D GND D GND D GND D GND 5V D GND 5V D GND D GND P or t7/DIO6 P or t7/DIO7 P or t8/DIO9 P or t8/DIO0 P or t8/DIO1 ...

  • National Instruments NI sbRIO-960x - page 10

    NI sbRIO-960x 10 ni.com Figure 7. Pinout of I/O Connector P4, 3.3 V Digital I/O P or t0/DIOCTL P or t0/DIO9 5V D GND 5V D GND D GND D GND D GND D GND P or t1/DIOCTL D GND D GND D GND D GND D GND D GND D GND D GND D GND P or t2/DIOCTL D GND D GND D GND D GND D GND P or t0/DIO1 P or t0/DIO2 P or t0/DIO4 P or t0/DIO5 P or t0/DIO6 P or t0/DIO7 P or t0/ ...

  • National Instruments NI sbRIO-960x - page 11

    © National Instruments Corporation 11 N I sbRIO-960x Figure 8. Pinout of I/O Connector P5, 3.3 V Digital I/O The follo wing fi gure and t able sho w the signals on J1, the RS-2 32 serial port. Figure 9. J1, RS-232 Serial Port P or t7/DIOCTL P or t7/DIO9 D GND D GND D GND P or t3/DIOCTL D GND D GND D GND D GND D GND D GND D GND D GND D GND P or t4/ ...

  • National Instruments NI sbRIO-960x - page 12

    NI sbRIO-960x 12 ni.com Connecting the sbRIO Device to a Network Use a standard Category 5 (CAT-5) or be tter Ethernet cable to connect the RJ-45 Ethernet port t o an Ethernet network. Caution T o pre vent data loss and to maintain the integrity of your Ethernet installat ion, do not use a cable longer than 100 m. If you need to build your own cabl ...

  • National Instruments NI sbRIO-960x - page 13

    © National Instruments Corporation 13 N I sbRIO-960x Powering the sbRIO Device The sbRIO device requires a power su pply connected to J3. The supply voltage and current must meet the specifications in the Power Requirements section of this document, but the actual power requirement depends on how the device is physically configured , programmed, a ...

  • National Instruments NI sbRIO-960x - page 14

    NI sbRIO-960x 14 ni.com Boot Options Table 3 lists the reset options availab le on sbRIO devices. These options determine how the FPGA behaves when the device is reset in va rious conditions. Note If you want a VI to run when loaded to the F PGA, complete the following steps. 1. Right-click the FPGA T arget item in the Project Explorer windo w in L ...

  • National Instruments NI sbRIO-960x - page 15

    © National Instruments Corporation 15 N I sbRIO-960x Configuring DIP Switches Figure 10. DI P Switches All of the DIP switches are in the OF F (up) position when the sbRIO de vice is shipped from National Instruments. SAFE MODE Switch The position of the SAFE MODE swit ch determines whether the embedded LabVIEW Real-Time engine launches at startup ...

  • National Instruments NI sbRIO-960x - page 16

    NI sbRIO-960x 16 ni.com • One stop bit • No flow control Keep this switch in the OFF position during normal operation. If CONSOLE OUT is enabled, LabVIEW R T cannot communicate wit h the serial port. IP RESET Switch Push the IP RESET swit ch to the ON position and reboot the sbRIO device to reset the IP address to 0.0 .0.0 . If the device is on ...

  • National Instruments NI sbRIO-960x - page 17

    © National Instruments Corporation 17 N I sbRIO-960x Using the Reset Button Pressing the Reset button reboots the processor. The FPGA continues to run unless you select the Autoload VI on D evice Reboot boot option. Refer to the Boot Optio ns section for more information. Understanding LED Indications Figure 11. sbRIO-960 x LEDs FPGA LED You can u ...

  • National Instruments NI sbRIO-960x - page 18

    NI sbRIO-960x 18 ni.com Resetting the Network Configuration of the sbRIO Device If the sbRIO device is not able to communicate with the network, you can use the IP RESET switch to manuall y restore the device to the factory network settings. When you restore the device to the facto ry network settings, the IP address, subnet mask , DNS address, gat ...

  • National Instruments NI sbRIO-960x - page 19

    © National Instruments Corporation 19 N I sbRIO-960x The network settings are restored. Y ou can reconfigure the settings in MAX from a computer on the sa me subnet. Refer to the Measur ement & Automation Explorer Help for m ore information about configuring the device. Note If the de vice is restored to the fact ory network settings, the Lab ...

  • National Instruments NI sbRIO-960x - page 20

    NI sbRIO-960x 20 ni.com During overvoltage conditi ons, high current flows through R1 and into the protection diodes. High current causes internal heatin g in the posistor, which increases the resistance and limits the current. Refer to the Specifications section for curr ent-limiting an d resistance values. Drive Strength The sbRIO devices were te ...

  • National Instruments NI sbRIO-960x - page 21

    © National Instruments Corporation 21 N I sbRIO-960x The OEM user is responsible for determining cabling requirements and ensuring that current limits are not exceeded. Specifications The following specifications are typical for the range – 20 to 55 °C unless otherwise noted. Network Network interface .................... .............. . 10Bas ...

  • National Instruments NI sbRIO-960x - page 22

    NI sbRIO-960x 22 ni.com 3.3 V Digital I/O Number of DIO channels ......... .............. .110 Maximum tested curren t per channel ..... 3 mA Maximum total current, al l lines .............33 0 mA Maximum tested DIO frequency ............10 MHz Input logic lev els Input high vo ltage, V IH ................... .2.0 V min; 5.25 V max Input low vol ta ...

  • National Instruments NI sbRIO-960x - page 23

    © National Instruments Corporation 23 N I sbRIO-960x Resistance-temperature char acteristics, typical curve Re s i s t a nce-T emper a t u re Ch a r a cteri s tic s T ypic a l C u rv e Re s i s t a nce Ch a nge (R/R25) Te m p e r a t u re (°C) – 40 – 20 0 20 40 60 80 100 120 140 160 1000 100 10 1 0.1 Gr a ph-1 ...

  • National Instruments NI sbRIO-960x - page 24

    NI sbRIO-960x 24 ni.com Power Requirements The sbRIO device requires a power su pply connected to connector J3. Refer to Figure 4 for the location of J3. Refer to the Powering the sbRIO Device section for information about connecti ng the power supply. Power supply voltage range ........... ......... 19–30 VDC 1 Power supply current limit ....... ...

  • National Instruments NI sbRIO-960x - page 25

    © National Instruments Corporation 25 N I sbRIO-960x Example power requirement calculations For an sbRIO-9602 with three inst alled board-only C Series modules, 20 mA total current through 3.3 V DIO pins, and 1 A of current through 5 V output, calculate the total power requirement as follo ws: P int = 6.0 W P CSer = 3.30 W P DIO = 0.08 W P 5V = 5. ...

  • National Instruments NI sbRIO-960x - page 26

    NI sbRIO-960x 26 ni.com For additional en vironmental information, refer to the NI and the Environment W eb page at ni.com/environment . This page contains the en vir onmental regulations and directives with which NI complies, as well as other en vironment al information not included in this docum ent. W aste Electrical and Electronic Equipment (WE ...

  • National Instruments NI sbRIO-960x - page 27

    © National Instruments Corporation 27 N I sbRIO-960x Cabling Table 5 shows the standard Ethernet cable wiring connectio ns for both normal and crossover cables. Figure 13. Ethernet Connector Pinout Table 5. Ethernet Cable Wiring Connections Pin Connector 1 Connector 2 (Normal) Connector 2 (Crossover) 1 white/orange white/orange white/green 2 orang ...

  • National Instruments NI sbRIO-960x - page 28

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more information abou t National Instruments trademarks. Other product and compan y names mentioned herein are t rademarks or trade names of their respective companie s . For patents covering Nati ...

Fabbricante National Instruments Categoria Computer Hardware

I documenti che otteniamo dal fabbricante del dispositivoNational Instruments NI sbRIO-960x possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici National Instruments
- manuali per l’uso NI sbRIO-960x
- schede prodotto National Instruments
- opuscoli
- o etichette energetiche National Instruments NI sbRIO-960x
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso National Instruments NI sbRIO-960x.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione National Instruments NI sbRIO-960x, manuali di manutenzione, brevi manuali o manuali utente National Instruments NI sbRIO-960x. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto National Instruments NI sbRIO-960x.

Manuale completo del dispositivo National Instruments NI sbRIO-960x, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare National Instruments NI sbRIO-960x dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti National Instruments NI sbRIO-960x.

Il manuale per l’uso completo National Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale National Instruments NI sbRIO-960x - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice National Instruments NI sbRIO-960x, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per National Instruments NI sbRIO-960x che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo National Instruments NI sbRIO-960x - che ci dovrebbe aiutare nei primi passi durante l'uso National Instruments NI sbRIO-960x
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del National Instruments NI sbRIO-960x
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio National Instruments NI sbRIO-960x in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su National Instruments NI sbRIO-960x?

Utilizza il modulo sottostante

Se non hai risolto il problema con National Instruments NI sbRIO-960x con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con National Instruments NI sbRIO-960x è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)