Manuale per l’uso Lincoln Electric EAGLE IM830

36 pagine 0.63 mb
Scarica

Vai alla pagina of 36

Summary
  • Lincoln Electric EAGLE IM830 - page 1

    EA GLE ™ 10,000 OPERA TOR’S MANUAL For Machines with Code Number: 11096 IM830 November, 2005 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAI ...

  • Lincoln Electric EAGLE IM830 - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric EAGLE IM830 - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric EAGLE IM830 - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric EAGLE IM830 - page 5

    Mar. ‘93 iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les ...

  • Lincoln Electric EAGLE IM830 - page 6

    Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay par ...

  • Lincoln Electric EAGLE IM830 - page 7

    vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .......................................................................................................A-1 Safety Precautions ............................. ...

  • Lincoln Electric EAGLE IM830 - page 8

    A-1 INST ALLA TION EAGLE 10,000 A-1 TECHNICAL SPECIFICA TIONS - EAGLE 10,000 (K2343-1 ) INPUT - GASOLINE ENGINE RA TED OUTPUT @ 104°F (40°C) - WELDER HEIGHT WIDTH DEPTH WEIGHT 30.3 in. 19.1 in. 42.0 in. 770 mm 485 mm 1067 mm 502 lbs. (228kg) RA TED OUTPUT @ 104°F (40°C) - GENERA TOR Welding Output DC Constant Current 210A / 25V / 100% Auxiliary ...

  • Lincoln Electric EAGLE IM830 - page 9

    A-2 INST ALLA TION EAGLE 10,000 A-2 SAFETY PRECAUTIONS MACHINE GROUNDING Because this portable engine driven welder or genera- tor creates it’s own power, it is not necessary to con- nect it’s frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.). To prevent dangerous electric shock, other equip- m ...

  • Lincoln Electric EAGLE IM830 - page 10

    3. Proper placement of the equipment on the trailer to insure stability side to side and front to back when being moved and when standing by itself while being operated or serviced. 4. Typical conditions of use, i.e., travel speed; rough- ness of surface on which the trailer will be operated; environmental conditions. 5. Conformance with federal, s ...

  • Lincoln Electric EAGLE IM830 - page 11

    A-4 INST ALLA TION EAGLE 10,000 A-4 ANGLE OF OPERA TION Internal combustion engines are designed to run in a level condition which is where the optimum perfor- mance is achieved. The maximum angle of operation for the engine is 15 degrees from horizontal in any direction. If the engine is to be operated at an angle, provisions must be made for chec ...

  • Lincoln Electric EAGLE IM830 - page 12

    A-5 INST ALLA TION EAGLE 10,000 A-5 INSTRUCTIONS ADDITIONAL SAFETY PRECAUTIONS Always operate the welder with the roof and case sides in place as this provides maximum protection from moving parts and assures proper cooling air flow. Read and understand all Safety Precautions before operating this machine. Always follow these and any other safety p ...

  • Lincoln Electric EAGLE IM830 - page 13

    A-6 INST ALLA TION EAGLE 10,000 A-6 120 V DUPLEX RECEPTACLES The 120V auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs. The current rating of any plug used with the system must be at least equal to the current load through the associated receptacle. MOTOR STAR ...

  • Lincoln Electric EAGLE IM830 - page 14

    A-7 INST ALLA TION EAGLE 10,000 A-7 TABLE lll ELECTRICAL DEVICE USE WITH THE EAGLE 10,000. Type Common Electrical Devices Possible Concerns Resistive Heaters, toasters, incandescent NONE light bulbs, electric range, hot pan, skillet, coffee maker. Capacitive TV sets, radios, microwaves, Voltage spikes or high voltage appliances with electrical cont ...

  • Lincoln Electric EAGLE IM830 - page 15

    A-8 INST ALLA TION EAGLE 10,000 A-8 STANDBY POWER CONNECTIONS The EAGLE 10,000 is suitable for temporary, standby, or emergency power using the engine manufacturer ’ s recommended maintenance schedule. The EAGLE 10,000 can be permanently installed as a standby power unit for 240V-3 wire, single phase 38 ampere service. (Connections must be made b ...

  • Lincoln Electric EAGLE IM830 - page 16

    240 Volt 60 Hz. 3-Wire Service POWER COMPANY METER 240 VOLT 120 VOLT 120 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION GND N NOTE: No. 6 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE SIZE RECOMMENDATIONS. 240 VOLT GROUNDED CONDUCTOR 40 AMP 240 VOLT DOUBLE POLE CIRCUIT BREAKER DOUBLE P ...

  • Lincoln Electric EAGLE IM830 - page 17

    WELDER CONTROLS - FUNCTION AND OPERA TION ENGINE SWITCH The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine. When placed in the “ OFF ” position, the ignition circuit is de-energized to shut down the engine. When held in the “ START ” position, the engine starter moto ...

  • Lincoln Electric EAGLE IM830 - page 18

    “ RANGE ” SWITCH Never change the “ RANGE ” Switch setting while welding. This will damage the switch. ------------------------------------------------------------------------ “ CONTROL ” DIAL Provides a fine welding current adjustment within the Range Switch settings. B-2 OPERA TION B-2 EAGLE 10,000 CAUTION KOHLER 20 H.P. COMMAND .39 G ...

  • Lincoln Electric EAGLE IM830 - page 19

    B-3 OPERA TION B-3 ST ARTING/SHUTDOWN INSTRUCTIONS STARTING THE ENGINE Be sure all Pre-Operation Maintenance has been per- formed. Also, read the Engine Owner ’ s Manual before starting for the frist time. Remove all loads connected to the AC power recepta- cles. Use the choke control as follows: KOHLER ENGINE - Always pull the choke control out ...

  • Lincoln Electric EAGLE IM830 - page 20

    ARC GOUGING The EAGLE 10,000 can be used for limited arc goug- ing. Set the Range switch to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following table: B-4 OPERA TION B-4 WELDING PROCESS For any electrodes the procedures should be kept within the rating of the machine. For electro ...

  • Lincoln Electric EAGLE IM830 - page 21

    B-5 OPERA TION B-5 EAGLE 10,000 SUMMARY OF WELDING PROCESSES CONTROL ELECTRODE CABLE IDLE WHEN NOT TO START PROCESS USED MODE WELDING WELDING STICK No AUTO Hot Touch electrode to work. Welding starts immediately and engine goes to high idle. WIRE FEED, LN-25 WITH No AUTO Cold Press gun trigger, LN-25 INTERNAL CONTACTOR contactor closes. Welding sta ...

  • Lincoln Electric EAGLE IM830 - page 22

    C-1 ACCESSORIES C-1 EAGLE 10,000 OPTIONAL EQUIPMENT (Field Installed) K957-1 HEAVY DUTY, TWO WHEEL TRAILER FOR SMALL WELDERS - For road, off-road and in-plant and yard towing. (For highway use, consult applicable federal, state and local laws regarding requirements for brakes, lights, fenders, etc.) Order K957-1 Trailer K958-1 Ball Hitch K958-2 Lun ...

  • Lincoln Electric EAGLE IM830 - page 23

    C-2 ACCESSORIES C-2 RECOMMENDED EQUIPMENT STICK K704(400 Amp) or K875(150 Amp)Accessory Kit which includes: • Electrode Holder & Cable • Work Clamp & Cable • Headshield WIRE FEED K449 LN-25 - Includes internal contactor for across the arc operation (no control cable). Provides “ cold ” electrode until gun trigger is pressed. Inclu ...

  • Lincoln Electric EAGLE IM830 - page 24

    Have qualified personnel do the maintenance work. Turn the engine off before working inside the machine. In some cases, it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the mainte- nance requiring their removal is complete. Always use the greatest care when working ...

  • Lincoln Electric EAGLE IM830 - page 25

    D-2 MAINTENANCE D-2 Use 4-stroke motor oil that meets or exceeds the requirements for API service classification SG or SH. Always check the API SERVICE label on the oil con- tainer to be sure it includes the letters SG or SH. SAE 10W-30 is recommended for general, all-tempera- ture use, -5 F to 104 F (-20 C to 40 C). See Engine Owner ’ s Manual f ...

  • Lincoln Electric EAGLE IM830 - page 26

    D-3 MAINTENANCE D-3 ENGINE ADJUSTMENTS OVERSPEED IS HAZARDOUS The maximum allowable high idle speed for this machine is 3750 RPM, no load. Do NOT tamper with governor components or setting or make any other adjustments to increase the maximum speed. Severe personal injury and damage to the machine can result if operated at speeds above maximum. --- ...

  • Lincoln Electric EAGLE IM830 - page 27

    E-1 TROUBLESHOOTING E-1 EAGLE 10,000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair pos ...

  • Lincoln Electric EAGLE IM830 - page 28

    E-2 TROUBLESHOOTING E-2 EAGLE 10,000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ( ...

  • Lincoln Electric EAGLE IM830 - page 29

    E-3 TROUBLESHOOTING E-3 EAGLE 10,000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ( ...

  • Lincoln Electric EAGLE IM830 - page 30

    STARTER CR1 STARTER SOLENOID 12 VOLT IDLER SOLENOID BATTERY AC AC B+ SWITCH REGULATOR FLYWHEEL ALTERNATO R B- HOUR METER 5E 5D 224 ENGINE COMPONENTS 224A 1 2 3 CONNECTOR PIN NU MBERS: 7 6 12 1 2 3 4 J1 N.A. B J2 SOLENOID FUEL SHUTOFF OIL PRESSURE TERMINAL BLOCK (SEE CONN.) 209A 209A 224C 210 B B GENERATOR LEAD END (NOTE CAVITY NUMBERS) LOCATING TAB ...

  • Lincoln Electric EAGLE IM830 - page 31

    F-2 DIAGRAMS F-2 EAGLE 10,000 EAGLE 1 0, 000 / L N-2 5 ACROSS T HE ARC CONNECTI ON DIAGRAM ELECTRIC SHOCK can kill Do not operate with panels open. Disconnect NEGATIVE (-) Battery lead before servicing. Do not touch electrical ly live parts. W A RNING MOVING PARTS can injure Keep guards in place. Keep away from moving parts. Only qualified per sonn ...

  • Lincoln Electric EAGLE IM830 - page 32

    F-3 DIAGRAMS F-3 EAGLE 10,000 A. A . 0 1 26.5 9 30.2 7 9.09 9.09 17.0 0 21.2 2 8.80 30.0 0 42.0 0 22.1 5 10.3 3 CE NTE R OF GR AVITY WITH O IL IN ENG INE AND FULL FU EL T ANK 9.31 CE NTE RLI NE OF SH AFT 9.59 10.1 9 OIL FILTER REM OVAL EAGLE 10,000 E A G L E 1 0 , 0 0 0 ...

  • Lincoln Electric EAGLE IM830 - page 33

    NOTES EAGLE 10,000 ...

  • Lincoln Electric EAGLE IM830 - page 34

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA E ...

  • Lincoln Electric EAGLE IM830 - page 35

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes ...

  • Lincoln Electric EAGLE IM830 - page 36

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabbricante Lincoln Electric Categoria Welder

I documenti che otteniamo dal fabbricante del dispositivoLincoln Electric EAGLE IM830 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Lincoln Electric
- manuali per l’uso EAGLE IM830
- schede prodotto Lincoln Electric
- opuscoli
- o etichette energetiche Lincoln Electric EAGLE IM830
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Lincoln Electric EAGLE IM830.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Lincoln Electric EAGLE IM830, manuali di manutenzione, brevi manuali o manuali utente Lincoln Electric EAGLE IM830. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Lincoln Electric EAGLE IM830.

Manuale completo del dispositivo Lincoln Electric EAGLE IM830, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Lincoln Electric EAGLE IM830 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Lincoln Electric EAGLE IM830.

Il manuale per l’uso completo Lincoln Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Lincoln Electric EAGLE IM830 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Lincoln Electric EAGLE IM830, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Lincoln Electric EAGLE IM830 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Lincoln Electric EAGLE IM830 - che ci dovrebbe aiutare nei primi passi durante l'uso Lincoln Electric EAGLE IM830
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Lincoln Electric EAGLE IM830
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Lincoln Electric EAGLE IM830 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Lincoln Electric EAGLE IM830?

Utilizza il modulo sottostante

Se non hai risolto il problema con Lincoln Electric EAGLE IM830 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Lincoln Electric EAGLE IM830 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)