  • Axor Showerpanel - page 1

    Interaktiv Showerpanel Installation Instructions / W arranty ...

  • Axor Showerpanel - page 2

    Interaktiv Showerpanel I Interaktiv Showerpanel II Showerpanel I Showerpanel II handshower & bodyjets handshower , bodyjets, tub spout Metro 06572000 06573000 Solaris 06549XX0 06550XX0 Stratos 06564XX0 06565XX0 Interaktiv S 06893000 06894000 Proaktiv* 06964000 06971000 Product Specification Flow rate of handshower 2.5 gpm Flow rate of each body ...

  • Axor Showerpanel - page 3

    Check Package Contents Save time and aggravation. Before beginning installation, check the contents of this package. Make sure that all parts are present and in good condition. If any par t is missing or damaged, please contact Hansgrohe Customer Ser vice before proceeding. T ools Required The following tools are suggested for installing the Intera ...

  • Axor Showerpanel - page 4

    Roughing-in This unit can be installed on a flat wall or in a 90 o corner . Instructions for installation on a flat wall begin on page 5. Go to page 8 if the panel is to be installed in a corner . Ensure that you have a minimum 83” ceiling height from the standing surface. Stub out 1/2" NPT male nipples for the hot and cold water supplies at ...

  • Axor Showerpanel - page 5

    Installation -- Flat W all W rap the threads on the supply nipples with T eflon thread tape. Install the enclosed elbows so that the outlets face upwards. Measure up the wall 78 ¾”, making sure that the line is plumb. Mark the position for the top screw hole. From the position of the top screw hole, measure down 35 3/8”. Mark the position for ...

  • Axor Showerpanel - page 6

    Use the compression nuts and ferrules to connect the supply hoses on the panel to the supply elbows. Use two wrenches, as shown, to prevent the supply hoses from twisting. Attach the seals to the side covers. Install the side covers. The pins on the covers must go into the grooves on the sides of the panel. 6 ...

  • Axor Showerpanel - page 7

    Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel. T urn to page 11 to continue the installation. 7 ...

  • Axor Showerpanel - page 8

    Installation in 90 o Corner W rap the threads on the nipples with T eflon thread tape. Install the enclosed elbows so that the outlets face upwards. In the corner , measure up the wall 78 ¾”, making sure that the line is plumb. Mark the position for the top mounting bracket. From the position of the top screw hole, measure down 35 3/8”. Mark t ...

  • Axor Showerpanel - page 9

    While a helper holds the panel, attach the supply hoses to the elbows with the compression fittings. Use two wrenches, as shown in the diagram, to prevent the supply hoses from twisting. T ighten the hex head cap screw on the top mounting bracket. Install and tighten the hex head cap screw on the bottom mounting bracket through the hole in the pane ...

  • Axor Showerpanel - page 10

    Clip the side cover seals as shown in the diagram. Attach the side cover seals to the valve cover . Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel. T urn to page 11 to continue the installation. 10 ...

  • Axor Showerpanel - page 11

    Install the Handle Push the handle over the valve stem. T ighten the set screw on the bottom of the handle with a 3 mm Allen wrench. The set screw must engage the slot milled into the thermoelement. Install the Handshower Place a black rubber washer in the short hose end connector . Screw the shor t hose end connector to the handshower outlet on th ...

  • Axor Showerpanel - page 12

    Justify the Handle T urn the temperature control knob so that the indicator is next to the 100 o marking. Replace the handle. T ighten the set screw . T urn the water on to the handshower . T ur n the temperature control knob so that the water mea- sures 100 o F on a thermom- eter . T urn the water off. Remove the handle. 12 ...

  • Axor Showerpanel - page 13

    Set the High T emperature Limit Stop (optional) Loosen the set screw on the handle. Remove the handle. Remove the clip and the high temperature limit stop from the stem. Grasp the barrel on the cartridge and tur n it counter - clockwise to turn on the handshower . T urn the stem until the water coming out of the handshower is the desired maximum hi ...

  • Axor Showerpanel - page 14

    Using the Handshower The handshower has 3 spray modes -- Rainl AIR, Whirl AIR, and Balance AIR. Push the function lever until the desired spray mode is achieved. User Instructions - Showerpanel I T urn the temperature control knob clockwise to make the water cooler , counter-clockwise to make it warmer . The knob will stop at the 100 o F position. ...

  • Axor Showerpanel - page 15

    Scale Removal The Raindance Air 3-jet handshower incorporates the Rubit TM cleaning system. If scale deposits are noticed in the spray channels, turn the water on lightly and rub the spray channels with a finger or a sponge. If scale deposits are noticed on the spray face, pour about 3/4” of a commercial scale remover , such as Lime-Away TM or CL ...

  • Axor Showerpanel - page 16

    A possible cause of lost pressure, especially if the pressure decreases as the temperature increases, is debris clogging the filter screens on the thermostatic cartridge. If this occurs, the screens should be cleaned. T urn the water off at the main. Remove the handle. Hold the thermoelement steady with a 36 mm wrench. Use a 24 mm wrench to unscrew ...

  • Axor Showerpanel - page 17

    Replacement Parts 1 slider 97024000 2 hose 28276XXX 3 shelf 25969000 4 sleeve 88520XXX 5 thermostat cartridge 94282000 6 thermoelement, panel I 88533000 thermoelement, panel II 88500000 7 side cover 25974880 8 valve cover , panel I 25976880 9 valve cover , panel II 25985880 10 escutcheon 25981XXX 11 handshower Solaris 28518XX1 Stratos 28507XX1 Metr ...

  • Axor Showerpanel - page 18

    Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY THE ...

  • Axor Showerpanel - page 19

    year , with respect to Interaktiv and Retroaktiv products, and (ii) for 5 years, with respect to AXOR, ShowerPower and Pharo products. THIS W ARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT P A Y FOR: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) ...

  • Axor Showerpanel - page 20

    Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770 360-9880 • Fax 770 360 9887 www .hansgrohe-USA.com US - Installation Instructions • Part No. 90972801-03 • Revised 12/2006 ...

Fabbricante Axor Categoria Plumbing Product

I documenti che otteniamo dal fabbricante del dispositivoAxor Showerpanel possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Axor
- manuali per l’uso Showerpanel
- schede prodotto Axor
- opuscoli
- o etichette energetiche Axor Showerpanel
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Axor Showerpanel.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Axor Showerpanel, manuali di manutenzione, brevi manuali o manuali utente Axor Showerpanel. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Axor Showerpanel.

Manuali per l’uso simili

Manuale completo del dispositivo Axor Showerpanel, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Axor Showerpanel dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Axor Showerpanel.

Il manuale per l’uso completo Axor, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Axor Showerpanel - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Axor Showerpanel, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Axor Showerpanel che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Axor Showerpanel - che ci dovrebbe aiutare nei primi passi durante l'uso Axor Showerpanel
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Axor Showerpanel
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Axor Showerpanel in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Axor Showerpanel?

Utilizza il modulo sottostante

Se non hai risolto il problema con Axor Showerpanel con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Axor Showerpanel è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)