Manuale per l’uso Orion PRO 120 EQ

20 pagine 0.41 mb
Scarica

Vai alla pagina of 20

Summary
  • Orion PRO 120 EQ - page 1

    INSTRUCTION MANUAL IN 189 Rev . B 04/05 Providi ng Exce ptional Consum er Opti cal Pro ducts S ince 19 75 Customer Support (800)-676-1343 E-mail: support@telescope.com Corporate Offices (831)-763-7000 P .O. Box 1815, Santa Cruz, CA 95061 Orion ® SkyV iew ™ Pr o 1 20 EQ #9867 Equatorial Refractor T elescope ...

  • Orion PRO 120 EQ - page 2

    2 Figure 1. The SkyView Pro 120 EQ. Declination lock lever (opposite side) Right Ascension lock lever (opposite side) Declination slow-motion control knob Safety thumbscrew Mounting plate securing knob Counterweight shaft Counterweights Counterweight lock knobs Objective lens Optical tube T ube rings Finder scope Finder scope bracket Eyepiece Star ...

  • Orion PRO 120 EQ - page 3

    3 T able of Contents 1. Unpacking. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2. Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4. Balancing the T elescope . . . . . . . . . . . . . . . . . 5 5. Using Y our T elescope . . . . . . . . . . . . . ...

  • Orion PRO 120 EQ - page 4

    1. Stand the tripod legs upright and spread the legs out as far as they will go. Keep the tripod legs at their shortest (fully retracted) length, for now; you can extend them to a more desirable length later , after the scope is fully assembled. 2. Place the base of the equatorial mount onto the tripod head. Orient the equatorial mount so that the ...

  • Orion PRO 120 EQ - page 5

    the mounting plate and rethread into the tube rings. Note that the side of the mounting plate with the central “groove” will be facing up. Use the small wrench to secure the tube rings to the mounting plate. 10. Loosen the black mounting plate securing knob as well as the metal safety thumbscrew on the top of the equatorial mount. Place the mou ...

  • Orion PRO 120 EQ - page 6

    6 The telescope is now balanced on both axes. When you loos- en the lock lever on one or both axes and manually point the telescope, it should move without resistance and should not drift from where you point it. 5. Using Y our T elescope Focusing the T elescope With the 25mm eyepiece inserted in the diagonal, move the telescope so the front (open) ...

  • Orion PRO 120 EQ - page 7

    achieved by focusing the finder scope on a bright star . Once the image appears sharp, retighten the locking ring behind the objective lens cell. The finder scope’s focus should not need to be adjusted again. Magnification & Eyepieces Magn ificati on, or po wer , is determ ined by th e focal l ength of the telescope and the focal length of th ...

  • Orion PRO 120 EQ - page 8

    8 knob. But first the R.A. axis of the mount must be aligned with the Earth’ s rotational (polar) axis—a process called polar alignment. Polar Alignment For Northern Hemisphere observers, approximate polar align - ment is achieved by pointing the mount’s right ascension axis at the North Star , or Polaris. It lies within 1° of the north cele ...

  • Orion PRO 120 EQ - page 9

    9 directly from your observing site, consult a compass and rotate the tripod so the telescope points north. There is a label bearing a large “N” at the base of the equatorial mount (Figure 8). It should be facing north. The equatorial mount is now polar aligned for casual observ - ing. More precise polar alignment is recommended for astro - pho ...

  • Orion PRO 120 EQ - page 10

    2. Loosen the Dec. lock lever and rotate the optical tube on the declination axis so that the tube is at a 90° to the right ascension axis (Figure 10). This is so you can view through the mount with the polar axis finder . T ighten the Dec. lock lever . 3. Remove the cap on the front of the equatorial mount (Figure 6). Focus the polar finder by ro ...

  • Orion PRO 120 EQ - page 11

    ments (there are 60 minutes in 1 hour of right ascension). The lower set of numbers apply to viewing in the Northern Hemisphere, while the numbers above them apply to viewing in the Southern Hemisphere. The Dec. setting circle is scaled in degrees, with each mark representing 2° increments. V alues of declination coordinates range from +90° to -9 ...

  • Orion PRO 120 EQ - page 12

    12 the scope in declination so it points to where you want it near the horizon. T o point the telescope directly south, the counterweight shaft should again be horizontal. Then you simply rotate the scope on the declination axis until it points in the south direction. T o point the telescope to the east or west, or in other direc - tions, you rotat ...

  • Orion PRO 120 EQ - page 13

    tion outside to cooler air (or vice-versa), a telescope needs time to cool to the outdoor temperature. The bigger the instru - ment and the larger the temperature change, the more time will be needed. Allow at least 30 minutes for your SkyView Pro 120 EQ to equilibrate. If the scope has more than a 40° temperature adjustment, allow an hour or more ...

  • Orion PRO 120 EQ - page 14

    14 Important Note: Do not look at the Sun with any optical instrument without a professionally made solar filter , or permanent eye damage could result. Also, be sure to cover the finder scope, or better yet, remove it altogeth - er . C. The Planets The pla nets don’t st ay put like the s tars, so to fin d them you should refer to Sky Calendar at ...

  • Orion PRO 120 EQ - page 15

    15 the stars you are centering in the eyepiece. Remember , the finder scope (and main telescope eyepiece, for that matter) gives an inverted image, so you must keep this in mind when starhopping from star to star . 8. Astrophotography Several dif ferent types of astrophotography can be success- fully attempted with the SkyView Pro 120 EQ. Moon Phot ...

  • Orion PRO 120 EQ - page 16

    est star within the field of view. Remove the eyepiece and insert the illuminated reticle eyepiece into the diagonal. Turn the eyepiece’s illuminator on (dimly!). Recenter the bright star (guide star) on the crosshairs of the reticle eyepiece. Check again to make sure that the object to be photographed is still centered within the camera’s fiel ...

  • Orion PRO 120 EQ - page 17

    17 es in temperature and humidity . Do not store the telescope outdoors, although storage in a garage or shed is OK. Small components like eyepieces and other accessories should be kept in a protective box or storage case. Keep the dust cover on the front of the telescope when not in use. Y our SkyView Pro 120 EQ requires very little mechanical mai ...

  • Orion PRO 120 EQ - page 18

    18 ...

  • Orion PRO 120 EQ - page 19

    19 ...

  • Orion PRO 120 EQ - page 20

    20 One-Y ear Limited W arranty This Orion SkyView Pro 120 EQ is warranted against defects in materials or workmanship for a period of one year from the date of purchase. This warranty is for the b enefit of the original retail purchaser only . During this warranty period Orion T elescopes & Binoculars will repair or replace, at Orion’s option ...

Fabbricante Orion Categoria Telescope

I documenti che otteniamo dal fabbricante del dispositivoOrion PRO 120 EQ possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Orion
- manuali per l’uso PRO 120 EQ
- schede prodotto Orion
- opuscoli
- o etichette energetiche Orion PRO 120 EQ
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Orion PRO 120 EQ.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Orion PRO 120 EQ, manuali di manutenzione, brevi manuali o manuali utente Orion PRO 120 EQ. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Orion PRO 120 EQ.

Manuali per l’uso simili

Manuale completo del dispositivo Orion PRO 120 EQ, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Orion PRO 120 EQ dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Orion PRO 120 EQ.

Il manuale per l’uso completo Orion, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Orion PRO 120 EQ - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Orion PRO 120 EQ, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Orion PRO 120 EQ che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Orion PRO 120 EQ - che ci dovrebbe aiutare nei primi passi durante l'uso Orion PRO 120 EQ
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Orion PRO 120 EQ
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Orion PRO 120 EQ in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Orion PRO 120 EQ?

Utilizza il modulo sottostante

Se non hai risolto il problema con Orion PRO 120 EQ con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Orion PRO 120 EQ è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)