    Voyager 9520/40 Voyager GS9590 Eclipse 5145 Quick Start Guide VG-ECL-QS Rev C 6/12 Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Gehe zu www.honeywellaidc.com für Deutsch. Ir a www.honeywellaidc.com para español. Para Português, acesse www.honeywellaidc.com.br . Перейти на русск? ...

  • Honeywell 9520/40 - page 2

    Getting Started Turn off the computer’s power be fore connecting the scanner, then power up the computer once th e scanner is fully connected. Connecting the Scanner USB: Serial (RS232): Keyb oa rd We d g e : optional adapter cable ...

  • Honeywell 9520/40 - page 3

    Reading T echniques Recall Defaults Scan Enable Factory Defaults , then Recall Defaults to reset all standard product default settings. Interface Selections USB ³ 999998 Recall Defaults ³ 846600 Enable Factory Defaults ³ 999970 ³ 316400 USB Keyboard Emulation Load Integrated Full Speed USB IBM/OEM Defaults ³ 316460 USB Serial Emulation ...

  • Honeywell 9520/40 - page 4

    Ke yboard W edge Ke yboard Country Scan a bar code to select one of the following keyboard country templates. Refer to your Config uration Guide for additional keyboard country settings. ³ 5155143 Keyboard Wedge Emulation ³ 416210 ³ 416220 United Kingdom ³ 416230 Germany/Austria France ³ 416260 United States ³ 416200 Belgium ³ 416250 Spain ? ...

  • Honeywell 9520/40 - page 5

    AL T Mode If your bar code contains special characters from the extended ASCII chart, for example, an e with an accent grave (è), scan the ALT Mode On bar code. The data is then output with the special character(s). Note: Scan ALT mode after scan ning the appropriate Keyboard Country code. RS232 Communication Commands ³ 116217 ALT Mode On ³ 1158 ...

  • Honeywell 9520/40 - page 6

    Prefix Scan one of the following bar codes to program your scanner to add or remove a start of text character, or AIM, NCR, or Nixdorf identification characters before each bar code. ³ 116615 ³ 116605 ³ 107905 ³ 107901 STX Prefix On STX Prefix Off ³ 107915 AIM ID Prefix On AIM ID Prefix Off ³ 107911 NCR Prefix On NCR Prefix Off ³ 107907 ³ 1 ...

  • Honeywell 9520/40 - page 7

    Suffix Scan one of the following bar codes to program your scanner to add or remove a carriage return, line feed , tab, or end of text after each bar code. ³ 116613 ³ 116603 ³ 116604 CR Suffix On CR Suffix Off ³ 116612 LF Suffix On ³ 116602 LF Suffix Off ³ 116610 Tab Suffix On ³ 116600 Tab Suffix Off ³ 116614 ETX Suffix On ETX Suffix Off ...

  • Honeywell 9520/40 - page 8

    User Configurable Prefix/Suffix One or two prefix or suffix charac ters can be added and assigned for data transmission. Use one of th e codes below with a 3 code byte sequence that represents the desired character ( see ASCII Conversion Chart , end of document) for your prefix or suffix. (To add additional prefix/suffix characte rs, refer to your ...

  • Honeywell 9520/40 - page 9

    Supplements Scan one of the bar codes below to program your scanner for 2 or 5 digit bar code supplements. 977 (2 Digit) Supplement Required: Turn on this feature when a 2 digit supplement is re quired for EAN-13 codes that begin with 977. ³ 101217 2 Digit Supplements On ³ 101207 2 Digit Supplements Off ³ 101216 5 Digit Supplements On ³ 101206 ...

  • Honeywell 9520/40 - page 10

    UPC/EAN Formatting Scan Convert UPC-A to EAN-13 and a leading zero is transmitted before a UPC-A bar code to convert it to EAN-13. Scan Transmit Lead Zero on UPC-E to transmit a zero before each UPC-E bar code. Scan Transmit UPC-A Number System to transmit the UPC-A leading digit with the bar code data. To transmit just the data, without the leadin ...

  • Honeywell 9520/40 - page 11

    Expand UPC-E to 12 Digits ex pands the UPC-E code to the 12 digit, UPC-A f or mat. When Code 39 Full ASCII On is scanned, cer tain character pairs within the bar code symbol will be inter preted as a single character . F or example: $V will be decoded as the ASCII character SYN, and / C will be decoded as the ASCII character #. ³ 107515 Expand UPC ...

  • Honeywell 9520/40 - page 12

    Check Digits The following selections allow you to specify whether the check digit should be transmitted at the end of the scanned UPC-A or UPC-E data or not. CodeGate/Manual Activ ation (V oy ager 9520/40, V oy agerGS 9590) Use the following programming code s to control CodeGate button/ trigger functions. An y time CodeGate is Active , you must p ...

  • Honeywell 9520/40 - page 13

    Host Configurations Scan one of the following codes, then scan the Recall Defaults code, to program the scanner for on e of the following configurations. Miscellaneous Minimum Symbol Length specifies the minimum number of characters allowable for non-UP C/EAN bar codes. Scan the Enter/ Exit Programming bar code to begin. Scan Minimum Symbol Length ...

  • Honeywell 9520/40 - page 14

    Code Bytes ³0 ³1 ³3 ³5 ³2 ³4 ³6 ³7 ³9 ³8 ...

  • Honeywell 9520/40 - page 15

    ASCII Con version Char t Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char 0 00 NUL 26 1A SUB 52 34 4 78 4E N 104 68 h 1 01 SOH 27 1B ESC 53 35 5 79 4F O 105 69 i 2 02 STX 28 1C FS 54 36 6 80 50 P 106 6A j 3 03 ETX 29 1D GS 55 37 7 81 51 Q 107 6B k 4 04 EOT 30 1E RS 56 38 8 82 52 R 108 6C l 5 05 ENQ 31 1F US 57 39 9 83 53 S 109 6D m ...

  • Honeywell 9520/40 - page 16

    T echnical Assistance Contact information for technical support, product service, and repair can be found at www.honeywellaidc.com . Limited W arranty Refer to www.honeywellaidc.com/warranty_information for your product’s warranty information. User Documentation For localized versions of this doc ument, and to download the Configuration Guide or ...

Fabbricante Honeywell Categoria Barcode Reader

I documenti che otteniamo dal fabbricante del dispositivoHoneywell 9520/40 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Honeywell
- manuali per l’uso 9520/40
- schede prodotto Honeywell
- opuscoli
- o etichette energetiche Honeywell 9520/40
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Honeywell 9520/40.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Honeywell 9520/40, manuali di manutenzione, brevi manuali o manuali utente Honeywell 9520/40. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Honeywell 9520/40.

Manuali per l’uso simili

Manuale completo del dispositivo Honeywell 9520/40, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Honeywell 9520/40 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Honeywell 9520/40.

Il manuale per l’uso completo Honeywell, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Honeywell 9520/40 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Honeywell 9520/40, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Honeywell 9520/40 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Honeywell 9520/40 - che ci dovrebbe aiutare nei primi passi durante l'uso Honeywell 9520/40
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Honeywell 9520/40
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Honeywell 9520/40 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Honeywell 9520/40?

Utilizza il modulo sottostante

Se non hai risolto il problema con Honeywell 9520/40 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Honeywell 9520/40 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)