Manuale per l’uso Mitsubishi Electronics PCA-RP-KA

22 pagine 1.21 mb
Scarica

Vai alla pagina of 22

Summary
  • Mitsubishi Electronics PCA-RP-KA - page 1

    ...

  • Mitsubishi Electronics PCA-RP-KA - page 2

    2 This symbol mark is for EU countries only . This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV , and/or to the directive 2006/66/EC Article 20 Information for end-users and Annex II. Y our MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which ...

  • Mitsubishi Electronics PCA-RP-KA - page 3

    3 ■ Indoor Unit PKA-RP·HAL PCA-RP·KA PCA-RP·HA PSA-RP·GA Fan speed 3 speeds + Auto 4 speeds + Auto 2 speeds 2 speeds Vane Auto with swing Auto with swing Manual Manual Louver Manual Manual Manual Auto with swing Filter Normal Long-life Oil Long-life Filter cleaning indication 100 hr 2,500 hr 100 hr 2,500 hr 2. Parts Names Filter Air intake Lo ...

  • Mitsubishi Electronics PCA-RP-KA - page 4

    4 ˚ F ˚ C ˚ F ˚ C ERROR CODE AFTER TIMER TIME SUN MON TUE WED THU FRI SAT ON OFF Hr AFTER FILTER FUNCTION ONLY1Hr. WEEKLY SIMPLE AUTO OFF PAR-21MAA ON/OFF FILTER CHECK OPERATION CLEAR TEST TEMP. MENU BACK DAY MONITOR/SET CLOCK ON/OFF 2. Parts Names ■ Wired Remote-Controller Note: ● “PLEASE WAIT” message This message is displayed for app ...

  • Mitsubishi Electronics PCA-RP-KA - page 5

    5 1 2 3 2. Parts Names ■ Wireless Remote-Controller ■ When using the wireless remote controller, point it towards the receiver on the indoor unit. ■ If the remote controller is operated within approximately 2 minutes after power is supplied to the indoor unit, the indoor unit may beep twice as the unit is performing the initial automatic chec ...

  • Mitsubishi Electronics PCA-RP-KA - page 6

    6 3. Screen Con fi guration <Screen Types> For details on setting the language for the remote controller display, refer to section 8. Function Selection. The initial language setting is English. ● Function Selection of remote controller: Set the functions and ranges available to the remote controller (timer functions, operating restriction ...

  • Mitsubishi Electronics PCA-RP-KA - page 7

    7 5. Operation 5.2. Mode select ■ Press the operation mode ( ) button 2 and select the opera- tion mode 2 . Cooling mode Drying mode Fan mode Heating mode <Only heat pump type> Automatic (cooling/heating) mode <Only heat pump type> Ventilation mode Only indicated on the following condition Wired remote controller used LOSSNAY connecte ...

  • Mitsubishi Electronics PCA-RP-KA - page 8

    8 5. Operation Note: ● Available directions depend on the type of unit connected. ● In the following cases, the actual air direction will differ from the direction indicated on the remote controller display. 1. While the display is showing “STAND BY” or “DEFROST”. 2. Immediately after starting heat mode (while the system is waiting for ...

  • Mitsubishi Electronics PCA-RP-KA - page 9

    9 C C TIME SUN WEEKLY 10 C TIMER SUN ON OFF WEEKLY 8 9 1 Timer Settings 1. Be sure that the weekly timer indicator is visible on the screen (at 1 ). 2. Press the Timer Menu button 2 so that “Monitor” is indicated on the screen (at 8 ). 3. Press the Timer On/Off (Set Day) button 9 as necessary to select the day you wish to view. 4. Press the or ...

  • Mitsubishi Electronics PCA-RP-KA - page 10

    10 <How to Set the Simple Timer> 6. Timer Action (On or Off) * “— —” is displayed if there is no setting. Timer Setting ON Hr AFTER SIMPLE 4. With “ON” or “OFF” showing at 3 : Press the appropriate Set Time but- ton as necessary to set the hours to ON (if “ON” is displayed) or the hours to OFF (if “OFF” is displayed) a ...

  • Mitsubishi Electronics PCA-RP-KA - page 11

    11 <Checking the Current Auto Off Timer Setting> AFTER TIMER OFF AUTO OFF Timer Setting ˚ C ˚ C AFTER OFF AUTO OFF AUTO OFF 1. Be sure that the “Auto Off” is visible on the screen (at 1 ). 2. Hold down the Timer Menu button 2 for 3 seconds so that “Monitor” is indicated on the screen (at 4 ). • The timer remaining to shutdown appe ...

  • Mitsubishi Electronics PCA-RP-KA - page 12

    12 7.1. Locking the Remote Controller Buttons (Opera- tion function limit controller) ■ If you wish, you can lock the remote controller buttons. You can use the Function Selection of remote controller to select which type of lock to use. (For information about selecting the lock type, see section 8, item [2] (1)). Speci fi cally, you can use eit ...

  • Mitsubishi Electronics PCA-RP-KA - page 13

    13 8. Function Selection Function selection of remote controller The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when needed. Item 1 Item 2 Item 3 (Setting content) 1. Change Language (“CHANGE LAN- GUAGE”) Language setting to display • Display in m ...

  • Mitsubishi Electronics PCA-RP-KA - page 14

    14 8. Function Selection OFF no1 no2 OFF ON OFF ON OFF OFF CALL- ON OFF ON OFF ˚ C ˚ F PAR-21MAA ON/OFF FILTER CHECK OPERATION CLEAR TEST TEMP . MENU BACK DAY MONITOR/SET CLOCK ON/OFF English Germany Spanish Russian Italian Chinese French Japanese Item 3 Item 2 Item 1 Hold down the button and press the button for 2 seconds. Hold down the button a ...

  • Mitsubishi Electronics PCA-RP-KA - page 15

    15 [Detailed setting] [4]-1 CHANGE LANGUAGE setting The language that appears on the dot display can be selected. • Press the [ MENU] button G to change the language. 1 English (GB), 2 German (D), 3 Spanish (E), 4 Russian (RU), 5 Italian (I), 6 Chinese (CH), 7 French (F), 8 Japanese (JP) Refer to the dot display table. [4]-2 Function limit (1) Op ...

  • Mitsubishi Electronics PCA-RP-KA - page 16

    16 8. Function Selection [Dot display tab le] Waiting f or star t-up Operation mode Cool Dr y Heat Aut o Auto(Cool) Auto(Heat) Fa n V entilation Stand by (Hot adjust) Defrost Set temperature F an speed Not use button Check (Error) T est run Self check Unit function selection Setting of ventilation CHANGE LANGUA GE Function selection Operation funct ...

  • Mitsubishi Electronics PCA-RP-KA - page 17

    17     E.O. SW 10. Care and Cleaning ON/OFF TEMP . C C FIL TER Note: • Details of emergency mode are as shown below. Operation mode COOL HEAT Set temperature 24°C 24°C Fan speed High High Air fl ow direction Horizontal Downward 4 (5) ■ Indicates that the fi lter needs cleaning. Clean the fi lter. ■ When resetting “FILTER” ...

  • Mitsubishi Electronics PCA-RP-KA - page 18

    18 10. Care and Cleaning   / 0 1 PSA-RP·GA       1 Open the intake grille. 2 Hold the knob on the fi lter then pull the fi lter up in the direction of an arrow. To replace the fi lter after cleaning, be sure to insert the fi lter far enough until it fi ts into the stopper. A Filter B Intake Grille C Knob D Stopper • ...

  • Mitsubishi Electronics PCA-RP-KA - page 19

    19 11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. ■ Clean the fi lter. (Air fl ow is reduced when the fi lter is dirty or clogged.) ■ Check the temperature adjustment and adjust the set temperature. ■ Make sure that there is plenty of space around the out ...

  • Mitsubishi Electronics PCA-RP-KA - page 20

    20 12. Speci fi cations Having trouble? Here is the solution. (Unit is operating normally.) Draining water or motor rotation sound is heard. ■ When cooling operation stops, the drain pump operates and then stops. Wait approximately 3 minutes. Noise is louder than speci fi cations. ■ The indoor operation sound level is affected by the acoustic ...

  • Mitsubishi Electronics PCA-RP-KA - page 21

    21 12. Speci fi cations Model PSA-RP71GA PSA-RP100GA PSA-RP125GA PSA-RP140GA Power source(voltage <V>/Frequency<Hz>) ~/N 230/50 Rated Input(Indoor only) <kW> 0.15/0.15 0.24/0.24 0.28/0.28 0.36/0.36 Rated Current(Indoor only) <A> 0.66/0.66 1.06/1.06 1.23/1.23 1.59/1.59 Heater <kW> ---- Dimension(Height) <mm> 1900 ...

  • Mitsubishi Electronics PCA-RP-KA - page 22

    HEAD OFFICE: T O KY O BLDG., 2-7-3, MAR UNOUCHI, CHIYOD A-KU, TOKY O 100-8310, JAP AN BG79U612H03 Printed in Japan Please be sure to put the contact address/telephone number on this manual before handing it to the customer. BG79U612H03.indd 22 BG79U612H03.indd 22 2008/12/11 9:03:08 2008/12/11 9:03:08 ...

Fabbricante Mitsubishi Electronics Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoMitsubishi Electronics PCA-RP-KA possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Mitsubishi Electronics
- manuali per l’uso PCA-RP-KA
- schede prodotto Mitsubishi Electronics
- opuscoli
- o etichette energetiche Mitsubishi Electronics PCA-RP-KA
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Mitsubishi Electronics PCA-RP-KA.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Mitsubishi Electronics PCA-RP-KA, manuali di manutenzione, brevi manuali o manuali utente Mitsubishi Electronics PCA-RP-KA. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Mitsubishi Electronics PCA-RP-KA.

Manuale completo del dispositivo Mitsubishi Electronics PCA-RP-KA, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Mitsubishi Electronics PCA-RP-KA dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Mitsubishi Electronics PCA-RP-KA.

Il manuale per l’uso completo Mitsubishi Electronics, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Mitsubishi Electronics PCA-RP-KA - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Mitsubishi Electronics PCA-RP-KA, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Mitsubishi Electronics PCA-RP-KA che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Mitsubishi Electronics PCA-RP-KA - che ci dovrebbe aiutare nei primi passi durante l'uso Mitsubishi Electronics PCA-RP-KA
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Mitsubishi Electronics PCA-RP-KA
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Mitsubishi Electronics PCA-RP-KA in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Mitsubishi Electronics PCA-RP-KA?

Utilizza il modulo sottostante

Se non hai risolto il problema con Mitsubishi Electronics PCA-RP-KA con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Mitsubishi Electronics PCA-RP-KA è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)