Manuale per l’uso National Instruments NI 9853

28 pagine 0.33 mb
Scarica

Vai alla pagina of 28

Summary
  • National Instruments NI 9853 - page 1

    OPERATING INSTRUCTIONS NI 9853 2-Port, High-Speed CAN Module ...

  • National Instruments NI 9853 - page 2

    NI 9853 Operating Instructions 2 ni.com These operating instructions desc ribe ho w to use the Natio nal Instruments (NI) 9853 module. F o r information about installing, configuring, and programming your system, refer to your system documentation. The NI 9853 module requires the NI 9853 software to be installed. The latest version of the NI 985 3 ...

  • National Instruments NI 9853 - page 3

    © National Instruments Corp. 3 NI 9853 Operating Instructions Safety Guidelines fo r Hazardous Loca tions The NI 9853 is suitable for use in Cl ass I, Division 2, Groups A, B, C, D, T4 hazardous locations; Clas s I, Zone 2, AEx nA II T4 and Ex nA II T4 hazardous locations ; and nonhazardous locations only . Follo w these guidelines if you ar e ins ...

  • National Instruments NI 9853 - page 4

    NI 9853 Operating Instructions 4 ni.com Caution For Zone 2 applications, install a protection device between the CAN signals and the NI 9853 CAN pins. The de vice must pre v ent the CAN Port-to-COM voltage from e xceeding 55 V if there is a transient ov ervoltage condition. Special Conditions fo r Safe Use in Europe This equipment has been evalua t ...

  • National Instruments NI 9853 - page 5

    © National Instruments Corp. 5 NI 9853 Operating Instructions one or both of the COM pins. Each port also has an o ptional shield pin, SHLD, that can be connect ed to a shielded CAN cable. Connecting SHLD may impro ve signa l integrity and EMC performance in a noisy en vironment. CAN0 of the NI 9853 is internally po wered, and therefore requires n ...

  • National Instruments NI 9853 - page 6

    NI 9853 Operating Instructions 6 ni.com Table 1. Pin Assignments for CAN0 Connector Pin Signal 1 No Connection (NC) 2 CAN_L 3 COM 4 NC 5 SHLD 6 COM 7 CAN_H 8 NC 9 NC 6 7 8 9 1 2 3 4 5 ...

  • National Instruments NI 9853 - page 7

    © National Instruments Corp. 7 NI 9853 Operating Instructions Table 2. Pin Assignments for CAN1 Connector Pin Signal 1 No Connection (NC) 2 CAN_L 3 COM 4 NC 5 SHLD 6 COM 7 CAN_H 8 NC 9 V SUP 6 7 8 9 1 2 3 4 5 ...

  • National Instruments NI 9853 - page 8

    NI 9853 Operating Instructions 8 ni.com CAN Bus T opology and T e rmination A CAN bus consists of two or more CAN nodes cabled together . The CAN_H and CAN_L pins of each node are connected to the main CAN bus cable through a short con nection kno wn as a “stub . ” The pair of signal wires, CAN_H and CAN_L constitutes a transmission line. If th ...

  • National Instruments NI 9853 - page 9

    © National Instruments Corp. 9 NI 9853 Operating Instructions Figure 1. CAN Bus T opology and T ermination Resistor Locati ons CAN Node CAN Node CAN Node R t R t CAN Node CAN_H CAN_L CAN_H CAN_L CAN_H CAN_L CAN_H CAN_L Bus Cable Length Stub Length ...

  • National Instruments NI 9853 - page 10

    NI 9853 Operating Instructions 10 ni.com Connecting a CAN Bus to the NI 9853 Each port of the NI 9853 can be connected to any location on a CAN bus. Figure 2 shows one exam ple of the con nection of CAN0 of the NI 9853 directly to one C AN node, and CAN1 directly to another CAN node. CAN1 requires an external power sup ply on the CAN bus. ...

  • National Instruments NI 9853 - page 11

    © National Instruments Corp. 11 NI 9853 Operating Instructions Figure 2. Connecting Both Ports of th e NI 9853 to CAN Buses CAN1 CAN Device CAN0 NI 9853 R t CAN Cable (With Optional Shield) (SHLD) CAN_H CAN_L V sup COM R t (SHLD) CAN_H CAN_L V sup COM CAN Device R t CAN Cable (With Optional Shield) (SHLD) CAN_H CAN_L V sup COM R t (SHLD) CAN_H CAN ...

  • National Instruments NI 9853 - page 12

    NI 9853 Operating Instructions 12 ni.com Cabling Requirements for NI 9853 This section deals wi th cabling specif icatio ns, termination resistors, cable lengths, and the number of CAN nodes that can exist in a system. Cable Specifications Cables should meet th e physical medium re quirements specified in ISO 11898, sho wn in T able 3. Beld en cabl ...

  • National Instruments NI 9853 - page 13

    © National Instruments Corp. 13 NI 9853 Operating Instructions T ermination Resistors The termination resistors (R t ) should match the nominal impedance of the CAN cable, and therefore comply wit h the v alues in T able 4. Cable Lengths The allo wabl e cable length is af fected by the chara cteristics of the cabling and the desired bit transmis s ...

  • National Instruments NI 9853 - page 14

    NI 9853 Operating Instructions 14 ni.com Number of CAN Nodes The maximum number of nodes depends on the electrical characteristics of the nodes on the ne twor k. If all of the nodes meet the requirements of ISO 11898, at least 30 nodes may be connected to the bus. Higher numbers of nodes may be connected if the electrical characteristics of th e no ...

  • National Instruments NI 9853 - page 15

    © National Instruments Corp. 15 NI 9853 Operating Instructions Figure 3. NI 9853 Hardware Overview Rx Tx CAN T r ansceiver +5 V_ISO +5 V GND COM CAN_H CAN_L +5 V Reg Rx Tx Ext Pwr Supply CAN Controller Rx Tx CAN Controller CAN_H CAN_L CAN T r ansceiver Rx Tx COM V sup CAN0 CAN1 + _ Iso Pwr ...

  • National Instruments NI 9853 - page 16

    NI 9853 Operating Instructions 16 ni.com Sleep Mode (CompactRIO Only) Y ou can enable sleep mode fo r the CompactRIO system in software. In sleep mode, the syst em consumes less power and may dissipate less heat. T ypically , when a system is in sleep mode, you cannot communicate with th e modules. Refer to the Spec ifications section for more info ...

  • National Instruments NI 9853 - page 17

    © National Instruments Corp. 17 NI 9853 Operating Instructions Specifications The follo wing spec ificat ions are typical for the range – 40 to 70 °C unless otherwise noted. High-Speed CAN Characteristics T ransceiv er .......... ........... ........... ........ Philips TJ A 1041 Max baud rate ............ ........... ........... . 1 Mbps CAN_H ...

  • National Instruments NI 9853 - page 18

    NI 9853 Operating Instructions 18 ni.com Power Requirements Power consumption from chassis Activ e mode T ransmitting ............. ............ 625 mW max Receiving ........ ........... .......... 400 mW max Sleep mode . ......... ........... ......... ... 25 μ W max Thermal dissipation (at 70 °C) Active mode ........ ......... ........... ... 1 ...

  • National Instruments NI 9853 - page 19

    © National Instruments Corp. 19 NI 9853 Operating Instructions Safety Maximum Voltage 1 Connect only v oltages that are wi thin these limits. Port-to-COM ....... ...................... ........ –27 to +40 VDC max, Measurement Category I Measurement Cate gory I is f or measurements performed on circuits not directly connected to the electrical di ...

  • National Instruments NI 9853 - page 20

    NI 9853 Operating Instructions 20 ni.com Isolation Voltages Port-to-port W ithstand .......... ............ ......... ..... 500 V rms , ver ifie d by a dielectric withstand test, 5 s Continuous .......... ......... ........... ... 60 VDC, Measurement Category I Port-to-earth ground W ithstand .......... ............ ......... ..... 500 V rms , ver ...

  • National Instruments NI 9853 - page 21

    © National Instruments Corp. 21 NI 9853 Operating Instructions Note For UL and other safety certif ications, refer to the product label, or vi sit ni.com/certification , search by model number or pro duct line, and click the appropriate link in the Certification column. Hazardous Locations U.S. (UL) ............ ......... ........... .......... Cl ...

  • National Instruments NI 9853 - page 22

    NI 9853 Operating Instructions 22 ni.com Environmental CompactRIO mod ules are inte nded for indoor u se only . F or outdoor use, mount the CompactRIO system in a suitably rated enclosure. Refer to the installa tion instructions for the chassis you are using for more information a bout meeting these specif ications. Operating temperature .......... ...

  • National Instruments NI 9853 - page 23

    © National Instruments Corp. 23 NI 9853 Operating Instructions Operating shock (IEC 60068-2-27)........... ........... ........ 30 g, 11 ms half sine, 50 g, 3 ms half sine, 18 shocks at 6 orientations Operating vibration, sinusoidal (IEC 60068-2-6) .... .......... 5 g, 10 to 500 Hz Electromagnetic Compatibility This product is designed to meet the ...

  • National Instruments NI 9853 - page 24

    NI 9853 Operating Instructions 24 ni.com CE Compliance This product meets the essentia l requirements of applicable European Directi ves, as amended for CE marking, as follo ws: • 2006/95/EC; Low-V oltage Directi ve (safety) • 2004/108/EC; Electromagneti c Compatibility Directive (EMC) Note Refer to the Declaration of Co nformity (DoC) for this ...

  • National Instruments NI 9853 - page 25

    © National Instruments Corp. 25 NI 9853 Operating Instructions For additional en vironmental information, refer to the NI and the Environment W eb page at ni.com/environment . This page contains the en vironmental regulat ions and directi v es with which NI complies, as well as othe r en vironmental information not included in this document. Waste ...

  • National Instruments NI 9853 - page 26

    NI 9853 Operating Instructions 26 ni.com National Instruments Contact Information National Instruments corporate headquarters is located at 11500 North Mopac Expressway , Austin, T exas, 78759-3504. National Instruments also has of fi ces located around the world to help address your support needs. F or telephone support in the United States, cr ea ...

  • National Instruments NI 9853 - page 27

    © National Instruments Corp. 27 NI 9853 Operating Instructions South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, T aiwan 886 02 2377 2222, Thailand 662 278 6777, T urk ey 90 212 279 3031, United Kingdom 44 (0) 1635 523545 ...

  • National Instruments NI 9853 - page 28

    © 2006–2008 Nati onal Instruments Corp. All rights reserved. 371453D-01 Jun08 National Instruments, NI, n i.com, and LabVIEW are trademarks of National Instruments C orporation. Refer to the Terms of Use section on ni.com /legal for more informat ion about National Inst ruments trademarks. Other product and company names ment ioned herein are tr ...

Fabbricante National Instruments Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoNational Instruments NI 9853 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici National Instruments
- manuali per l’uso NI 9853
- schede prodotto National Instruments
- opuscoli
- o etichette energetiche National Instruments NI 9853
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso National Instruments NI 9853.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione National Instruments NI 9853, manuali di manutenzione, brevi manuali o manuali utente National Instruments NI 9853. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto National Instruments NI 9853.

Manuale completo del dispositivo National Instruments NI 9853, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare National Instruments NI 9853 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti National Instruments NI 9853.

Il manuale per l’uso completo National Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale National Instruments NI 9853 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice National Instruments NI 9853, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per National Instruments NI 9853 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo National Instruments NI 9853 - che ci dovrebbe aiutare nei primi passi durante l'uso National Instruments NI 9853
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del National Instruments NI 9853
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio National Instruments NI 9853 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su National Instruments NI 9853?

Utilizza il modulo sottostante

Se non hai risolto il problema con National Instruments NI 9853 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con National Instruments NI 9853 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)