Manuale per l’uso Bryant 286B

14 pagine 0.73 mb
Scarica

Vai alla pagina of 14

Summary
  • Bryant 286B - page 1

    Installation Inst ructions 286B (2 - - 5 T ONS) 289B (3 TON TROPHY) EVOLUTION t SERIE S 2 - - ST AGE HEA T PUMP WITH PURON R REFRIGERANT SAF ETY CONSIDERA TIONS Imp ro per installatio n , adju stmen t, alteratio n, service, m ain tenan ce, or use ca n ca us e expl os ion, f ir e , ele c tr ic a l shoc k, or othe r condi t ions whi c h ma y ca use d ...

  • Bryant 286B - page 2

    2 INSULA TION SUCTION TUBE LIQUID TUBE OUTDOOR WALL INDOOR WALL LIQUID TUBE SUCTION TUBE INSULA TION CAULK HANGER STRAP (AROUND SUCTION TUBE ONL Y) JOIST 1” (25.4 mm) MIN THROUGH THE WALL SUSPENSION A07588 Fig. 1 - - Connec t ing T ubing In st all ati on Spec i fi c at ions for t hi s unit in res i dent i al ne w cons tr uc ti on mar ket re qui r ...

  • Bryant 286B - page 3

    3 Ma ke Piping Conne c tions ! W ARNING PERSONAL INJUR Y AND UNIT DAMAGE HAZARD Fai l ure to fol low t his war ning c ould r e sul t in pe r sona l inj ur y or dea th. Rel i eve pr e ss ure a nd re cove r a ll r ef r ige ra nt bef ore s yst e m re pa ir or f i nal uni t dis pos a l. Us e a ll s e rvi c e port s a nd open al l f low- - contr ol de v ...

  • Bryant 286B - page 4

    4 In st all Liq uid- -Line Filter D rier Ind oor ! W ARNING UNIT OPERA TION AND SAFETY HAZARD Fai l ure to f oll ow this wa rni ng c oul d re s ult in pe rs ona l inj ury or eq u ip m ent d am ag e. Puron R r e fr ige r ant sys t ems ope r at e at hi gher pre ss ur es t ha n st a ndar d R- -22 sys te ms . Do not us e R - -22 se rvi c e e qui pme nt ...

  • Bryant 286B - page 5

    5 Mak e El ectrica l Co n necti on s ! W ARNING ELECTRICAL SHOCK HAZARD Fai l ure to fol low t his war ning c ould r e sul t in pe r sona l inj ur y or dea th. Do not supply power t o unit wi t h compr e ss or t er mi nal box cove r r em oved. Be su re field wirin g co mp lies w ith local an d n atio nal fire, safety , and electrical co d es, an d ...

  • Bryant 286B - page 6

    6 Airfl ow S electi on fo r V ari ab l e Sp eed Fu rn aces (no n - - commun i cati ng ) Th e v ariab le speed fu rn aces p ro v id e blo w er op eratio n t o m atch th e capacities o f th e co mp resso r d u ring hig h and lo w stage co olin g op eratio n. T h e fu rn ace co ntro l bo ard allo w s th e in stalling techn ician to select the p ro p e ...

  • Bryant 286B - page 7

    7 Commun icati on and Status Fun ction Lights For Evol ut ion Cont r ol only , Gr ee n comm unic ati ons (COMM ) Light A green LE D (C OMM ligh t) on the out door boar d (s ee Fig. 6) ind icates successfu l comm u n ication w ith th e other system produc t s. The gr e en LED wil l re ma in OFF unt il c omm unic at i on is establish ed . Once a vali ...

  • Bryant 286B - page 8

    8 UTILITY RELAY * UTILITY SIGNAL OPEN RELAY * SUPPLIED BY UTILITY PROVIDER MODEL PLUG A06525 LLS Liquid Line Solenoid MODEL PLUG A06526 Fig. 6 - - 2- - Stage Cont r ol Board GENE RAL INFO RMA TIO N Evolution Controlled low ambient c ooling: This unit i s c a pabl e of low am bie nt cool i ng down to 0 ° F (- -17.8 ° C) wit hout a kit ONL Y when u ...

  • Bryant 286B - page 9

    9 Sta t us c ode 4 s hows t he fa n de la y de fe a t i s a ct ive (no del a y). Sta t us code 3 shows t ha t it i s not ac t ive ( 20 sec ond dela y) . The c ode wi ll cont i nue to be di s pla ye d unti l af t er the s hor t i s re move d. There i s a 5 se cond wa it bef or e the c ode is c anc e ll e d once t he s hort i s re move d. The code t ...

  • Bryant 286B - page 10

    10 Field Conne cti ons On non- -communi ca t ing ( non- - Evolut i on) s yst e m, the two- - st a ge con tro l receiv es 24vac l ow- -volta ge contr ol s yst e m input s thr ough the R , C, Y 1 , Y2 an d O co n n ection s lo cated at th e bo ttom o f the cont r ol boa rd ( s ee Fig. 6. ) On a non - -communi ca t ing s ys te m, output W1 is conne ct ...

  • Bryant 286B - page 11

    11 Conta cto r Sho rt ed Detection If there is com p resso r voltag e sensed w hen th ere is no d em and fo r com pre s sor ope ra tion, t he c ont ac tor m ay be s tuc k clos e d or t her e ma y be a w ir ing er r or . The c ontr ol will f l as h t he appr opri a te fa ult code . If t he c ontr ol se nse s t he compr e ss or vol ta ge aft e r st a ...

  • Bryant 286B - page 12

    12 OA T Thermis to r must b e lo cke d in pla ce with sp he r i- cal n ib e n d fa cin g to wa rds the f ron t of th e con trol box Fig. 8 - - Outdoor Ai r The rmi st or (O A T) Att achme nt OCT T h er mist or mu st be se cu re d tight on stu b tube. Fig. 9 - - Outdoor Coi l Ther mi st or ( OCT) Att ac hment Stat us Codes T a ble 5 shows t he s ta ...

  • Bryant 286B - page 13

    13 RVS/Heat Stage 2 O/B W 2 Heat Stage 1 W /W 1 Compressor Low Y 1 Compressor High Y/Y2 Fan G 24VAC Hot Heating Rh 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 24VAC Comm on C Humidify HUM Outdoor Air Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS Outdoor Sensor * Humidifier Solenoid Valve * Remote Room Sensor * O Y1 W1 G W2 C Y2 R W ...

  • Bryant 286B - page 14

    14 FINAL CHECKS IMPOR T ANT : Be f ore l ea vi ng job, be sur e to do the fol low ing: 1. E n sure that all wiring is rou ted aw ay fro m tu b in g and sheet me ta l e dges t o pre vent r ub- -through or wi re pi nc hing. 2. Ensur e tha t a ll wir ing and tubing is se cur e in unit bef ore add in g p anels and co v ers. Secu rely fasten all p an el ...

Fabbricante Bryant Categoria Heat Pump

I documenti che otteniamo dal fabbricante del dispositivoBryant 286B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bryant
- manuali per l’uso 286B
- schede prodotto Bryant
- opuscoli
- o etichette energetiche Bryant 286B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bryant 286B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bryant 286B, manuali di manutenzione, brevi manuali o manuali utente Bryant 286B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bryant 286B.

Manuali per l’uso simili

Manuale completo del dispositivo Bryant 286B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bryant 286B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bryant 286B.

Il manuale per l’uso completo Bryant, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bryant 286B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bryant 286B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bryant 286B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bryant 286B - che ci dovrebbe aiutare nei primi passi durante l'uso Bryant 286B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bryant 286B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bryant 286B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bryant 286B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bryant 286B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bryant 286B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)