For use in U.S./Canada Underwriter's Laboratories Report No. MH7603 87D1504 12/09 Rev . 4 FP583A WMC 12/18/98 ...
-
Monessen Hearth CWC500 - page 2
2 CW C Series W oodbur ning Fireplace 87D1504 Read all instructions an ...
-
Monessen Hearth CWC500 - page 3
3 CW C Series W oodb ur ning Fir eplace 87D1504 50" (1270mm) 42" (1067mm) 35 Z v " (895mm) 46" (1 168mm) B, " (16mm) B, " (16mm) Zx " (13mm) Zx " 19 Cv " (502mm) 1 Cv " (45mm) 38" (965mm) 21" (533mm) 7 Cv " (197mm) 7 Z x " (191mm) Recessed Nailing Flange FP592A WMC42 SPE ...
-
Monessen Hearth CWC500 - page 4
4 CW C Series W oodb ur ning Fir eplace 87D1504 Insulation methods shown are optional for cold climate, not a requirement for unit operation. FPC554 Fireplace and chase parts identification. T ermination Cap Storm Collar Pan Flashing Draftstop T op Shield Surround Outlet Gril ...
-
Monessen Hearth CWC500 - page 5
5 CW C Series W oodb ur ning Fir eplace 87D1504 D RISE B G H B OFFSET C E 6 FT . G H A HEARTH FLOOR CHIMNEY SECTION CHIMNEY FLUE EXIT ELBOW FPC269 Chimney Requirements -typ. offset Circulating models 1/28/99 djt 30˚ OFFSET ELBOW 30˚ OFFSET ELBOW 30˚ RETURN ELBOW 30˚ RETURN ELBOW SKCS8 SUPPORT Example 1 Example 2 Example 3 ? ...
-
Monessen Hearth CWC500 - page 6
6 CW C Series W oodb ur ning Fir eplace 87D1504 Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run. ...
-
Monessen Hearth CWC500 - page 7
7 CW C Series W oodb ur ning Fir eplace 87D1504 The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9 m) with SK8 chimneys or 20' (6 m) with 3-wall chimneys ...
-
Monessen Hearth CWC500 - page 8
8 CW C Series W oodb ur ning Fir eplace 87D1504 Framing can be constructed before or after the fire- place is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1 and 2 for basic fireplace specifica ...
-
Monessen Hearth CWC500 - page 9
9 CW C Series W oodb ur ning Fir eplace 87D1504 Since you have already preplanned the chimney run, you should know exactly how the installation is to be accomplished - how much pipe is required, the number of elbows, if any , and type of termination to be used. REPORT TO YOUR DEALE ...
-
Monessen Hearth CWC500 - page 10
10 CW C Series W oodb ur ning Fir eplace 87D1504 Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level. The following table gives firestop spacer model n ...
-
Monessen Hearth CWC500 - page 11
1 1 CW C Series W oodb ur ning Fir eplace 87D1504 An outside air kit is installed in all CWC Series Fire- places. If desired, or if local codes mandate the use of an air kit, then an AK-MST is required to complete the installation (from air kit to the outdoors). If the ...
-
Monessen Hearth CWC500 - page 12
12 CW C Series W oodb ur ning Fir eplace 87D1504 FP593 SR/C 11/20/97 Installing firestop spacer . FP593 Nails (4) Firestop Spacer Joist Joist Firestop Spacer Nails (4) FP263 Attic shie ...
-
Monessen Hearth CWC500 - page 13
13 CW C Series W oodb ur ning Fir eplace 87D1504 Size of roof hole varies with the type of chimney ter- mination installed. Refer to installation instructions provided with the chimney termination to find correct size of roof hole. There must be an air space (1 Zx " - SK8; ...
-
Monessen Hearth CWC500 - page 14
14 CW C Series W oodb ur ning Fir eplace 87D1504 used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace open- ing to bottom of mantel shelf. All joints (top, bottom and sides) where wall or deco- rative facing material meets fireplace surround must be completely sealed with a noncombustible mat ...
-
Monessen Hearth CWC500 - page 15
15 CW C Series W oodb ur ning Fir eplace 87D1504 1. Manville - CERAFORM 126, K=.27, 1/2 inches thick 2. MHSC - EH2416, K = .458, 1 inch thick required. A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 24 for minimum dimensions and mount ...
-
Monessen Hearth CWC500 - page 16
16 CW C Series W oodb ur ning Fir eplace 87D1504 COMMON MA TERIALS AND F ACTORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (MHSC) R V alue is for 1/2 inch. * Units of K = BTU/SQ FT/HR /˚F/IN ** Thickness of Listed Material FP533ADD Addendum 6/1/99 djt 8/4/99 changed .2 to .1 one inch to 1/2 inch ...
-
Monessen Hearth CWC500 - page 17
17 CW C Series W oodb ur ning Fir eplace 87D1504 Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.1 1.2, are to be installed in this fireplace. If installing an unvented gas log set, refer to statement below: ? ...
-
Monessen Hearth CWC500 - page 18
18 CW C Series W oodb ur ning Fir eplace 87D1504 2-583 Parts page 3/2/99 djt 1 2 3 4 5 6 12 8 10 9 11 15 14a,b 17 16 18 OFF LOW 13 7 2 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ? ...
-
Monessen Hearth CWC500 - page 19
19 CW C Series W oodb ur ning Fir eplace 87D1504 The following accessories for this appliance are available from your local distributor . Should you need additional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361; Attn: T echnical Services. ...
-
Monessen Hearth CWC500 - page 20
20 CW C Series W oodb ur ning Fir eplace 87D1504 Round T op T ermination T op used to terminate chimney at roof. RL TSK8 (SK8) (Flashing not included.) Round T op T ermination - T op used to terminate chimney at chase. RL TSK8L Extended (SK8) (Flashing not included.) Flashing Metal finishing re ...
-
Monessen Hearth CWC500 - page 21
21 CW C Series W oodb ur ning Fir eplace 87D1504 Square Chase T ermination Square chimney cap used to terminate chimney SL TS8 through chase. Includes adapter . (Flashin ...
-
Monessen Hearth CWC500 - page 22
22 CW C Series W oodb ur ning Fir eplace 87D1504 ...
-
Monessen Hearth CWC500 - page 23