  • Bloomfield 2216 - page 1

    BLOO MFIEL D IND USTRI ES 2 ERIK CIRCLE, P .O .Box 280 V erd i, NV 89439 U.S.A. Custom er Service (775) 345- 0444 Ex t.502 fax ( 775) 34 5-0569 ww w .w el ls bl oom fi el d. co m OWNERS MANU AL LX DECANTER BREWER MODELS 2212 2216 2216EX 2272 2274EX Includes INSTALLAT ION OPERAT ION USE & CARE SERVICE p/n 74733 Rev. D M656 05 0208 cps 656 Model ...

  • Bloomfield 2216 - page 2

    All electrical equipment ma nufactured by BLOOMFIELD INDUSTRI ES is w arranted against d efects in m aterials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefi t of the original purchaser, except that: a. ai ...

  • Bloomfield 2216 - page 3

    ELECTRICAL SPECIFIC A TIONS* MODEL WAT TS VOLTS 1ø Hz CIRCUIT REQUIRED WIRE 2212 1800 120 50/60 15 AMP ( NEMA 5-15R ) 2 + ground 2216 3500 120/240 50/60 HARD WIRE TO CIRCUIT BREAKER 3 + ground 2272 1800 120 50/60 15 AMP ( NEMA 5-15R ) 2 + ground 2216EX 3500 240 50/60 HARD WIRE TO CIRCUIT BREAKER 2 + ground 2274EX 3500 240 50/60 HARD WIRE TO CIRCUI ...

  • Bloomfield 2216 - page 4

    FEATURES & OPERATING CONTROLS 1. Brew Indicator Glows during brew cycle, flas hes in “Brew W ait” 2. Heat Indicator Glows when heating elem ents are energized 3. Power Indicator Glows when power is on 4. Warmer Indicators Glow when individual warmers are turned on 5. Brew Key Press to initiate bre w cycle 6. Cancel Key Press to terminate br ...

  • Bloomfield 2216 - page 5

    PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels w hich require the use of tools. Failure to heed this w arning c an resu lt in electrical shock . WA RNING : Injury Hazar d All installation pr ...

  • Bloomfield 2216 - page 6

    INSTALLATION INSTRUCTIONS RE A D THIS C A R EFULL Y BEFORE ST ARTING THE INST A LL A TION REFER TO EXPLODED VIEWS PAGES 16 thru 19 FOR COMPONENT NAMES/NUMBERS 1. Unpack the unit. Inspec t a ll components for comp leteness and condition. Ensure that all packing materials have been removed from the unit. 2. (See page 13.) Remove the Top W armer Unit ...

  • Bloomfield 2216 - page 7

    INSTALLATION INSTRUCTIONS (contin ued) NOTE: This equipment must be installed to comply with applica- ble f ederal, state and local codes and ordin a nc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground. Electrical shock will cause death or ...

  • Bloomfield 2216 - page 8

    OPERATION To over-ride th e Br ew Wait mode , press and hold the BR E W key for 3 second s when the brewer is in Brew Wait mode (i.e. when brew light is flashing). The brew will proceed immediatel y regardless of water temper ature. This f eature should onl y be used whe n testing water volume, otherwise the br ew will proceed with the water below ...

  • Bloomfield 2216 - page 9

    OPERATION (continued) WA R NI NG : Burn H azard. This applianc e dispenses very hot liquid. Serious bodily injury from scalding can occ ur from contact wi th dispensed liquids. CAUTION: Burn Hazard To avoid splashing or overflowing hot liqu ids, ALWAYS use an empty decanter before starting the brew cycle . Failure to comply can cause serio us burns ...

  • Bloomfield 2216 - page 10

    CLEANING INSTRUCTIONS CA UTI ON: Burn Hazard Brewing an d serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CA UTIO N: Electric Shoc k Hazard Do not submerge or i mmerse brewer in wat er. Do not pour or splash water into o r over air vents, control panel or warmer plates. IMPORTANT: DO NOT use steel wool, s ...

  • Bloomfield 2216 - page 11

    A. Adjust Brew Time B. Adjust Brew Temperature C. Adjust Quality Timer D. Adjust Dripout Timer E. Adjust After Hours Timer AB CD E UNDE R TOP COVER (IN SECO NDS) BREW TIME R (IN °F) BREW TEMP (I N 5 MIN I NCR) QUALI TY TIM ER (IN SECONDS) DRIPOU T TIMER (IN ONE HR INCR) AFTER HOU RS T IMER WA TE R LEVEL PROBE TEMP PROBE 20 185 6 OFF 3 60 90 30 70 ...

  • Bloomfield 2216 - page 12

    SERVICING INSTRUCTIONS — ELECTRICAL OPERATION SEE PAGE 11 FOR COMPONENT NAMES / NUMBERS 1. Pressing the PO W ER key energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Automatic fill is acco mplished via a FILL SOLENOID (32) and a W ATER LEVEL PROBE (7). The probe senses ground through the water in the tank. When the water le ...

  • Bloomfield 2216 - page 13

    27 28 WARM ER MOUN TI NG 3 5 4 20 32 18 7 8 15 17 4 E-MA XLX ELECT RICAL COMPONENT 12 0V UNITS 12 0/2 40V UNITS SERVICING INSTRUCTIONS — ELECTRICAL 3 PROBE, TEMPERATURE (THERMISTOR) 4 THERMOSTAT, HI-LIMIT 5 GROMMET 7 PROBE, WATER LEVEL 8 SLEEVE, WATER LE VEL PROBE 15 ELEMENT, W ATER HEATING 17 ASSEMBLY, TRIAC & HEAT SINK 18 BREW SOLENOID 2 ...

  • Bloomfield 2216 - page 14

    OPERATION SEE PAGE 13 FOR COMPONENT NAMES/NUMBERS 1. W ater enters at the inlet fi tting of the fill solenoid (32). The solenoid adm its water via a command from the controller. N OTE: The soleno id has an inter nal strainer. To clean the strainer: Shut off water supply. Unscrew the plastic cap protruding from the rear of the brewer. Remove the c a ...

  • Bloomfield 2216 - page 15

    SERVICING INSTRUCTIONS — PLUMBING 13 ITEM DESCRI PTION P ART N0. U SED ON 1 2 ASS E MBL Y , W A TER T ANK (120 V) 83500 2212, 22 72 6 GA SKE T , T AN K L ID 83 499 AL L 9 T ANK L ID 83 504 ALL 10 RET AINING CLIP , T ANK LID 83506 ALL 1 1 HOS E, OV ERFL O W (2 pc SILIC O NE 4.5” LO NG) 86014 ALL 12 HOSE , F AUCE T SUPPL Y (SIL ICONE, 10” LONG) ...

  • Bloomfield 2216 - page 16

    SERVICING INST RUCTIONS — DE-LIMING HEA TER TANK 1. Disconnect br ewer form the electrical sup pl y. Turn off the water suppl y and disc onnect water suppl y from the brewer inlet fitting. 2. Remove the top panel or top wa rmer section to gain access to internal components. 3. Disconnect water level sensor and w ater te mperature sensor from the ...

  • Bloomfield 2216 - page 17

    SERVICING INSTRUCTIO NS — DIAGNOSTICS & TROUBLESHOOTIN G) If the E-Max™ LX goes into an error mode as outlined below , it will probably be necessary to reset the bre w er in order to test individual components. Note the reset proce dure below : * FOR “LOW W ATER” OR “OVERHEAT” ERRORS: PRESS & HOLD CANCEL FOR 3 SECONDS, OR RE-ENE ...

  • Bloomfield 2216 - page 18

    EXPLODED VIEW — IN-LINE MODELS 16 ...

  • Bloomfield 2216 - page 19

    PARTS LIST — IN-LIN E MODELS 17 ...

  • Bloomfield 2216 - page 20

    EXPLODED VIEW — STEP-UP MODELS 18 ...

  • Bloomfield 2216 - page 21

    PA RTS LIST — STEP -UP M ODE L S 19 ...

  • Bloomfield 2216 - page 22

    WIRING DIAGRAM — IN-LINE MOD ELS 20 ...

  • Bloomfield 2216 - page 23

    WIRING DIAGRAM — I N-LINE EXPORT MODEL 21 ...

  • Bloomfield 2216 - page 24

    CONTROL BOARD 1 WP3 2 WP2 3 WP1 1 Heat er ( Line ) 2 Inlet ( Line) 3 Dump Line 4 Power (Line) 5 6 Dump (Neut) 7 Power (Neut) 8 Heater (Neut) Lin e Load Ga te Fr ont Wa rm er P late #2 120V 100 Watt Main Warme r P late 12 0V 100 Watt Rear War mer Pl ate #3 12 0V 100 Watt Out let Va l v e In let Va l v e 120 Volt 15 00 Wat t Ta n k H e a t e r Hi- Li ...

  • Bloomfield 2216 - page 25

    WIRING DIAGRAM — STEP-UP EXPORT MODEL 23 ...

  • Bloomfield 2216 - page 26

    Blo omfi eld Ind ustries , In c. Divis ion of Carri er Refrige r atio n In U S In C an ada PO Box 28 0, V e rdi, NV 89439 T el ephone: 775- 345-0444 Servi ce: 88 8-492-2782 Fax: 888-792-278 3 websit e: www . wellsbl oomfi eld.com T el ephone: 877- 507-1700 Servi ce: 90 5-507-1700 Fax: 905-507-1777 website: www .bl oomcan.com Bloomfi eld I ndustr ie ...

Fabbricante Bloomfield Categoria Coffeemaker

I documenti che otteniamo dal fabbricante del dispositivoBloomfield 2216 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bloomfield
- manuali per l’uso 2216
- schede prodotto Bloomfield
- opuscoli
- o etichette energetiche Bloomfield 2216
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bloomfield 2216.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bloomfield 2216, manuali di manutenzione, brevi manuali o manuali utente Bloomfield 2216. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bloomfield 2216.

Manuali per l’uso simili

Manuale completo del dispositivo Bloomfield 2216, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bloomfield 2216 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bloomfield 2216.

Il manuale per l’uso completo Bloomfield, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bloomfield 2216 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bloomfield 2216, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bloomfield 2216 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bloomfield 2216 - che ci dovrebbe aiutare nei primi passi durante l'uso Bloomfield 2216
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bloomfield 2216
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bloomfield 2216 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bloomfield 2216?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bloomfield 2216 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bloomfield 2216 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)