Manuale per l’uso Napoleon BGD48N

28 pagine 2.57 mb
Scarica

Vai alla pagina of 28

Summary
  • Napoleon BGD48N - page 1

    W415-0326 / C / 1 1.23.07 1 W415-0326 / C / 1 1.23.07 $10.00 ...

  • Napoleon BGD48N - page 2

    W415-0326 / C / 1 1.23.07 2 Framing Minimum Mantel and Enclosure Clearances Nailing T ab Installation 19-20 FINISHING Log Placement Charcoal Embers V ermiculite Glowing Embers Logo Placement Louvre Installation 21 OPTIONAL BLO WER INST ALLA TION 21 OPTIONAL F AN INST ALLA TION / GD36 THERMOST A TIC SENSOR CONTROL 22 OPERA TION / MAINTENANCE Operati ...

  • Napoleon BGD48N - page 3

    W415-0326 / C / 1 1.23.07 3 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. NAPOLEON® products are manufactured under the strict Standard of the wor ...

  • Napoleon BGD48N - page 4

    W415-0326 / C / 1 1.23.07 4 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BGD48 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. Installation practices vary from region to region and it is important ...

  • Napoleon BGD48N - page 5

    W415-0326 / C / 1 1.23.07 5 FIGURE 1 INST ALLA TION O VER VIEW FIGURE 2 ...

  • Napoleon BGD48N - page 6

    W415-0326 / C / 1 1.23.07 6 Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components.Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-V ent, Selkirk Dir ...

  • Napoleon BGD48N - page 7

    W415-0326 / C / 1 1.23.07 7 MINIMUM AIR TERMINAL L OCA TION CLEARANCES FIGURE 3 ...

  • Napoleon BGD48N - page 8

    W415-0326 / C / 1 1.23.07 8 FIGURE 5 SPECIAL VENT INST ALLA TIONS NO TE: When ter minating v er ticall y , the restrictor plate W500- 0205 must be installed. R efer to R estricting Vertical V ents. PERISCOPE TERMINA TION TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS FIGURES 4 a-b Use only GD401 periscope kit to locate the air termination above grade. Th ...

  • Napoleon BGD48N - page 9

    W415-0326 / C / 1 1.23.07 9 VER TICAL TERMINA TION HORIZONT AL TERMINA TION vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertical rise is less than horizontal ru ...

  • Napoleon BGD48N - page 10

    W415-0326 / C / 1 1.23.07 10 ELBOW VENT LENGTH V ALUES DEFINITIONS HORIZONT AL TERMINA TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFF- SETS IN FEET (H T ) FIGURE 6 45º FIGURE 7 90° H 1 H 2 when (H T ) < (V T ) Simple venting confi guration (only one 45º and 90° elbow) for the following symbols used in t ...

  • Napoleon BGD48N - page 11

    W415-0326 / C / 1 1.23.07 11 V 1 HORIZONT AL TERMINA TION See graph to determine the required vertical rise V T for the required hori- zontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 8 REQUIRED VERTICAL RISE I ...

  • Napoleon BGD48N - page 12

    W415-0326 / C / 1 1.23.07 12 VERTICAL TERMIN A TION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03 (one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < ...

  • Napoleon BGD48N - page 13

    W415-0326 / C / 1 1.23.07 13 H 1 VERTICAL TERMIN A TION For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 feet Example 4: when (H T ) > (V T ) Simple venting confi gurations See graph to determine the required vertical rise V T for ...

  • Napoleon BGD48N - page 14

    W415-0326 / C / 1 1.23.07 14 FIGURE 16 14 7 /16" W x 16 1 /4" H. See fi gure16. This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napoleon® dealer . See Accessories to order the specifi c kit required. 1. Determine the air terminal location, cut and frame 12 3 / 4 &q ...

  • Napoleon BGD48N - page 15

    W415-0326 / C / 1 1.23.07 15 FIGURE 25 4. Insert the liners through the fi restop maintaining the required clearance to combustibles. Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall and make weather tight by sealing with caulking (not supplied). 5. Apply a heavy bead of the high temperature sealan ...

  • Napoleon BGD48N - page 16

    W415-0326 / C / 1 1.23.07 16 FIGURE 31 RESTRICTOR PLA TE TOP OF THE FIREBOX FLUE COLLAR The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel vent spacers or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent ...

  • Napoleon BGD48N - page 17

    W415-0326 / C / 1 1.23.07 17 Proceed once the vent installation is complete. NOTE: All gas connections must be contained within the fi re- place when complete. 1. Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base. 2. The fi replace is designed to accept 3/8" gas supply ...

  • Napoleon BGD48N - page 18

    W415-0326 / C / 1 1.23.07 18 MINIMUM MANTEL AND ENCLOSURE CLEARANCES Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. Cur- tains, above the fi replace, must not be positioned lower than the 2" distance required for the 2" combustible mantel. These same requir ements ...

  • Napoleon BGD48N - page 19

    W415-0326 / C / 1 1.23.07 19 NAILING TA B FIGURE 39 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts. If there are no existing holes, follow these instructions: Position the nailing ...

  • Napoleon BGD48N - page 20

    W415-0326 / C / 1 1.23.07 20 B A Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner . Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers. Note: Both char coal embers and v ermiculite are not to be placed on the burner . 4. Place the sma ...

  • Napoleon BGD48N - page 21

    W415-0326 / C / 1 1.23.07 21 FIGURE 50 FIGURE 45 INST ALLA TION TO BE DONE BY A QUALIFIED INST ALLER and must be electrically connected and grounded in accord- ance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELEC - TRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United States If ...

  • Napoleon BGD48N - page 22

    W415-0326 / C / 1 1.23.07 22 When lit for the fi rst time, the fi replace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. After extended periods of non-operation ...

  • Napoleon BGD48N - page 23

    W415-0326 / C / 1 1.23.07 23 Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.- Adjust- ment may be required depending on fuel type, vent confi guration and a ...

  • Napoleon BGD48N - page 24

    W415-0326 / C / 1 1.23.07 24 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE ** 4 W010-0796 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0797 PROP ANE GAS PILOT ASSEMBL Y 5* W573-0008 HIGH TEMPERA TURE SEALANT 6* W660-0005 ON/OFF TOGGLE SWITCH 7 W455-0070 NA TURAL GAS PILOT INJECTOR - #62 7 W455-0068 PROP ANE GAS PILOT INJECTOR - # ...

  • Napoleon BGD48N - page 25

    W415-0326 / C / 1 1.23.07 25 ...

  • Napoleon BGD48N - page 26

    W415-0326 / C / 1 1.23.07 26 TR OUBLE SHOO TING GUIDE Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button igniter . - check if the push button igniter needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cra ...

  • Napoleon BGD48N - page 27

    W415-0326 / C / 1 1.23.07 27 SYMPT OM PROBLEM TEST SOLUTION Flames are consist- ently too large or too small. Carboning oc- curs. - check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read 7" (minimum 4.5") water ...

  • Napoleon BGD48N - page 28

    W415-0326 / C / 1 1.23.07 28 NO TES ...

Fabbricante Napoleon Categoria Indoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoNapoleon BGD48N possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Napoleon
- manuali per l’uso BGD48N
- schede prodotto Napoleon
- opuscoli
- o etichette energetiche Napoleon BGD48N
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Napoleon BGD48N.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Napoleon BGD48N, manuali di manutenzione, brevi manuali o manuali utente Napoleon BGD48N. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Napoleon BGD48N.

Manuali per l’uso simili

Manuale completo del dispositivo Napoleon BGD48N, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Napoleon BGD48N dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Napoleon BGD48N.

Il manuale per l’uso completo Napoleon, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Napoleon BGD48N - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Napoleon BGD48N, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Napoleon BGD48N che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Napoleon BGD48N - che ci dovrebbe aiutare nei primi passi durante l'uso Napoleon BGD48N
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Napoleon BGD48N
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Napoleon BGD48N in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Napoleon BGD48N?

Utilizza il modulo sottostante

Se non hai risolto il problema con Napoleon BGD48N con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Napoleon BGD48N è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)