  • American Water Heater AGT-705-PI - page 1

    Tankless W ater Heater System Design Manual Plumbing schematics for single and multiple tankless water heaters in use with domestic systems, recirculation, and storage tanks. PRINTED 0708 186965-000 ...

  • American Water Heater AGT-705-PI - page 2

    2 Certifications .................................................................................. 3 Water Quality and Scale ................................................................ 4 Pump Sizing for Circulation .......................................................... 5 T able of Contents Tank Water Heaters in a Circulation Loop Addition ...

  • American Water Heater AGT-705-PI - page 3

    3 Approvals Certified to applicable U.S. standards for appliances using gas or other petroleum fuel. Certified to applicable Canadian standards for appliances using gas or other petroleum fuel. Certified by the Uniform Plumbing Code (UPC) Certified by National Sanitation Foundation (NSF), www.nsf.org (indoor models must use the NSF approved top gua ...

  • American Water Heater AGT-705-PI - page 4

    4 W ater Quality and Scale A complete water analysis and an unde rstanding of system requirements are needed to prote ct the tankless water heaters and water heating systems from scale. Water analysis shows whether water is hard or soft. Hard water, unless treated, will cause scaling or liming of the heat exchanger. The rate of scaling increases wi ...

  • American Water Heater AGT-705-PI - page 5

    5 Pump Sizing for Circulation 1. Use the chart below or one appropriate for your co nditions to determine the heat loss in the length of the hot water supply and return piping. For example, 100 ft of 1-1/2 in bare copper tubing results in a heat loss of 5300 Btu/h. 2. Determine the acceptable temperature drop at the last fixture in the loop. For ex ...

  • American Water Heater AGT-705-PI - page 6

    6 T ank W ater Heaters in a Circulation Loop The following applies when using a tank water heater (gas or electric) to provide heat for a circulation loop. Drawing WH-1-RGE is an example. The heat output of the tank must be equal to or greater than the calculated circulation loop heat loss. (Reference page 6, Step 1 on calculating heat loss). Elect ...

  • American Water Heater AGT-705-PI - page 7

    The following applies when using tankless water heaters to recover a storage tank. Drawing WH-1-B is an example. Tankless water heaters have a pressure loss which must be considered in the system design. Reference the pressure loss curve for the heater m odel being used to determine the pump size for the desired recovery rate. For recommended pump ...

  • American Water Heater AGT-705-PI - page 8

    8 Pressure Loss Curves Pressure Loss (psi) Water Flow (gpm) 0. 0 5. 0 10. 0 15. 0 20. 0 25. 0 30. 0 35. 0 40. 0 45. 0 01 234 56 789 1 0 1 1 0. 0 10. 0 20. 0 30. 0 40. 0 50. 0 60. 0 Pressure Loss (ft head) 705 305 i 505 305 e ...

  • American Water Heater AGT-705-PI - page 9

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-1 Domestic Hot W ater - S tandard Installation 1 Tankless Water Heater Preferred Piping Installation G a s S u p p ly 3 / 4 " C o l d W a t e r ...

  • American Water Heater AGT-705-PI - page 10

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-2 Domestic Hot W ater - S tandard Installation 2 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an engineering ...

  • American Water Heater AGT-705-PI - page 11

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-3 Domestic Hot W ater - S tandard Installation 3 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an engineeri ...

  • American Water Heater AGT-705-PI - page 12

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-4 Domestic Hot W ater - S tandard Installation 4 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an engineering ...

  • American Water Heater AGT-705-PI - page 13

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-5 Domestic Hot W ater - S tandard Installation 5 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an engineeri ...

  • American Water Heater AGT-705-PI - page 14

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-6 Domestic Hot W ater - S tandard Installation 6 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an engineeri ...

  • American Water Heater AGT-705-PI - page 15

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-1-D Domestic Hot W ater - O p t i o n a l F r eeze Protection 1 Outdoor Tankless W ater Heater Preferred Piping Installation June 11, 2007 This is n ...

  • American Water Heater AGT-705-PI - page 16

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-2-D Domestic Hot W ater - O p t i o n a l F r eeze Protection 2 Outdoor Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This ...

  • American Water Heater AGT-705-PI - page 17

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-3-D Domestic Hot W ater - O p t i o n a l F r eeze Protection 3 Outdoor Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This ...

  • American Water Heater AGT-705-PI - page 18

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-6-D Domestic Hot W ater - O p t i o n a l F r eeze Protection 6 Outdoor Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This ...

  • American Water Heater AGT-705-PI - page 19

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-1-RGE Domestic Hot W ater - C i r c u l a t i o n S y s t e m s 1 Tankless W ater Heater with Gas or Electric Tank Preferred Piping Installation Feb ...

  • American Water Heater AGT-705-PI - page 20

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-1-R Domestic Hot W ater - C irculation Systems 1 Tankless W ater Heater Optional Piping Installation June 11, 2007 This is not an engineering dra ...

  • American Water Heater AGT-705-PI - page 21

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-2-RGE Domestic Hot W ater - C i r c u l a t i o n S y s t e m s 2 Tankless W ater Heaters with Gas or Electric Tank Preferred Piping Installation Fe ...

  • American Water Heater AGT-705-PI - page 22

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-2-R Domestic Hot W ater - Circulation Systems 2 Tankless W ater Heaters Optional Piping Installation February 27, 2008 This is not an engineering dr ...

  • American Water Heater AGT-705-PI - page 23

    23 Domestic Hot Water - Circulation Systems 3 Tankless Water Heaters with Gas or Electric Tank Preferred Piping Installation Tankless Water Heater Tankless Water Heater Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boi ...

  • American Water Heater AGT-705-PI - page 24

    24 Tankless Tankless Tankless Tankless Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-6-RGE Domestic Hot W ater - C i r c u l a t i o n S y s t e m s 6 Tankless W ater Heaters with Gas or Elec ...

  • American Water Heater AGT-705-PI - page 25

    25 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-1-B Domestic Hot W ater - Backup Storage 1 Tankless W ater Heater Preferred Piping Installation February 27, 2008 This is not an engineering draw ...

  • American Water Heater AGT-705-PI - page 26

    26 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-1-B-R Domestic Hot W ater - Backup Storage / Circulation 1 Tankless W ater Heater Preferred Piping Installation February 27, 2008 This is not an ...

  • American Water Heater AGT-705-PI - page 27

    27 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-2-B Domestic Hot W ater - Backup Storage 2 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an engineering dra ...

  • American Water Heater AGT-705-PI - page 28

    28 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-2-B-R Domestic Hot W ater - Backup Storage / Circulation 2 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not ...

  • American Water Heater AGT-705-PI - page 29

    29 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-3-B Domestic Hot W ater - B a c k u p S t o r a g e 3 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an e ...

  • American Water Heater AGT-705-PI - page 30

    30 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-3-B-R Domestic Hot W ater - Backup Storage / Circulation 3 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an ...

  • American Water Heater AGT-705-PI - page 31

    31 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-6-B Domestic Hot W ater - Backup Storage 6 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an engineering dra ...

  • American Water Heater AGT-705-PI - page 32

    32 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e WH-6-B-R Domestic Hot W ater - Backup Storage / Circulation 6 Tankless W ater Heaters Preferred Piping Installation February 27, 2008 This is not an ...

  • American Water Heater AGT-705-PI - page 33

    Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e M-1-F 1 Tankless W ater Heater Maintenance - Scale Flush Procedure June 11, 2007 This is not an engineering drawing; it is intended only as a guide and ...

  • American Water Heater AGT-705-PI - page 34

    34 Notes ...

  • American Water Heater AGT-705-PI - page 35

    35 Notes ...

  • American Water Heater AGT-705-PI - page 36

    • 500 T ennessee Waltz Parkway • Ashland, TN 37015 • ...

Fabbricante American Water Heater Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoAmerican Water Heater AGT-705-PI possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici American Water Heater
- manuali per l’uso AGT-705-PI
- schede prodotto American Water Heater
- opuscoli
- o etichette energetiche American Water Heater AGT-705-PI
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso American Water Heater AGT-705-PI.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione American Water Heater AGT-705-PI, manuali di manutenzione, brevi manuali o manuali utente American Water Heater AGT-705-PI. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto American Water Heater AGT-705-PI.

Manuale completo del dispositivo American Water Heater AGT-705-PI, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare American Water Heater AGT-705-PI dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti American Water Heater AGT-705-PI.

Il manuale per l’uso completo American Water Heater, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale American Water Heater AGT-705-PI - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice American Water Heater AGT-705-PI, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per American Water Heater AGT-705-PI che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo American Water Heater AGT-705-PI - che ci dovrebbe aiutare nei primi passi durante l'uso American Water Heater AGT-705-PI
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del American Water Heater AGT-705-PI
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio American Water Heater AGT-705-PI in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su American Water Heater AGT-705-PI?

Utilizza il modulo sottostante

Se non hai risolto il problema con American Water Heater AGT-705-PI con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con American Water Heater AGT-705-PI è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)