    600 USER'S GUIDE for BLOOMFIELD TRADITIONA L DISPLACEMENT-TYPE COFFEE BREWERS Includes: Installation Checkout Theory of Operation Troubleshooting p/n 86772 Rev. (-) M600 102203 cps ...

  • Bloomfield 600 - page 2

    INTRODUCTION SAFETY WARNINGS AND PRECAUTIONS xi The technical co ntent of this ma nual represents current prod uc tio n m odels as of October, 2003. Data, specifications and materials, and model number designations are subject to change at an y time w ithout notice. This manual is intended for use by qualified service personnel. Bloomfield coffee b ...

  • Bloomfield 600 - page 3

    1 TABLE OF CONTENTS INSTALLATION PROCEDURES …………………………………….. 2 BREWER OVERALL CHECKOUT ……………………………………. 4 BREWING COFFEE …………………………………………………… 5 CLEANING INSTRUCTIO NS …………………………………………. 6 THEORY OF OPERAT ION WATER FLOW …? ...

  • Bloomfield 600 - page 4

    INSTALL A TION 2 RE A D THIS C A R EFULL Y BEFORE ST ARTING THE INST ALLA TION This general information may not apply to all models. Refer to the owners manual and any te chnical data sheets for your specific equipment for a dditional information. PREPARATION Unpack the unit. Inspec t all components for c o mpleteness and condition. Ensure that all ...

  • Bloomfield 600 - page 5

    INSTALLATION (continued) 3 NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes and ordinanc es. WARNING: SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground. Electrical shock will cause death or serious injury ...

  • Bloomfield 600 - page 6

    4 BREWER OVERA L L CHEC K-OUT BREWER CHECK-OUT These checks should be performed: • When th e brew er is instal led • During any service call on the brew er • During any subseq ue nt follow-up call IMPORTANT: Tank must be full of water bef ore pressing POWER key " ON ". Heating elements will be damaged if allowed to operate w ithout ...

  • Bloomfield 600 - page 7

    BREWING COFFEE PREPARATION Place one (1) genuin e Bloomfield paper filter in the brew chamber. Add a p re-measured amount of fresh co ffee gr ounds. Gently shake the brew cham ber to level the bed of grounds. Slide the brew chamber into place under th e brew head. POUR-OVER OPERATION BE sure “READY TO BREW” light is lit. Place the appropriate E ...

  • Bloomfield 600 - page 8

    CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brew er PRECAUTIONS: Disconnect brew er from electric powe r. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Brush 1. Disconnect brewer from electric power. Allow brewer to cool bef ore cleaning. 2. Remove airpot. 3. Remove and empty brew c ...

  • Bloomfield 600 - page 9

    THEORY OF OPERATION 7 POUR-OVER FEATURE Pouring any amount of cold wate r into the pour-over opening and into the basin pan forces an identical amount of hot water out of the tank and through the spray head into the brew chamber. AUTO M ATIC OPE R ATION Pressing BREW butt on e n ergizes the solenoid valve, allowing water from an external wa ter sup ...

  • Bloomfield 600 - page 10

    The faucet water coil is submerged in the hot water tank an d draws heat fr om the brew water. Faucet water flows through the bypass side of the water inlet and is not cont ro lled by the solenoid valve. The fauc et is at supply water press ure any time the faucet shut-off valve is O PEN . THEORY OF OPERATION (continued) 8 HOT WATER FAUCET Typical ...

  • Bloomfield 600 - page 11

    THEORY OF OPERATION (continued) Heat Control Diagram The heating elements are energized when line power is applied to the el ement term inals. Water temperature is sensed by a thermobulb inserted in to the wa ter tank. This te mpe rature signal is fed to the thermost at by a capillary tube. An increase in temperature causes an in crea se in pressur ...

  • Bloomfield 600 - page 12

    TROUBLESHOOTING GUIDE 10 QUICK GUIDE The first step in troubleshooting is to determine w h ere to start. A few simple checks sho uld quickly point to the major area of concern. SYSTEM PAGE BREW W ATER - AUTOMATIC OPERATION .....……..… 11 BRE W W ATER - POUR-OVER ……………………… ..….. 12 FAUCET W ATER … ………………… … ...

  • Bloomfield 600 - page 13

    TROUBLESHOOTING GUIDE (continued) 11 BREW W A TER SYSTEM - AUTOMATIC OPERATION ...

  • Bloomfield 600 - page 14

    TROUBLESHOOTING GUIDE (continued) 12 BREW W A TER SYSTEM - AUTOMATIC OPERATION ...

  • Bloomfield 600 - page 15

    TROUBLESHOOTING GU IDE (continued) 13 BRE W W A TER SYSTEM - AUTOMATIC IMPORTANT: To avoid overf low ing the brew container, ALW AYS star t the brew with an empty container under the brew head. ...

  • Bloomfield 600 - page 16

    TROUBLESHOOTING GUIDE (continued) 14 BRE W W A TER SYSTEM - AUTOMA TIC OR POUR-O VER OPERATION ...

  • Bloomfield 600 - page 17

    TROUBLESHOOTING GU IDE (continued) 15 BREW W A TER SYSTEM - POUR-OVER OPERATION ...

  • Bloomfield 600 - page 18

    TROUBLESHOOTING GUIDE (continued) 16 FAUCET W ATER SYSTEM ...

  • Bloomfield 600 - page 19

    TROUBLESHOOTING GU IDE (continued) 17 FAUCET W ATER SYSTEM ...

  • Bloomfield 600 - page 20

    TROUBLESHOOTING GUIDE (continued) 18 FAUCET W ATER SYSTEM ...

  • Bloomfield 600 - page 21

    TROUBLESHOOTING GU IDE (continued) 19 ELECTRICAL SYSTEM - BREW CA UTIO N: ELECTRIC SHOCK HA ZAR D Exposed electric circuits. Use due caution when work in g near live ele ctric circuits. ...

  • Bloomfield 600 - page 22

    TROUBLESHOOTING GUIDE (continued) 20 ELECTRICAL SYSTEM - HEATING CAUTION: ELECTRIC SHOCK HA ZARD Exposed electric cir cu i ts. Use due caution when w orking near live electric circuits. ...

  • Bloomfield 600 - page 23

    TROUBLESHOOTING GU IDE (continued) 21 CAUTION: ELECTRIC SHOCK HA ZARD Exposed elec tric circuits. Use due caution w hen working near live electric circuits. ...

  • Bloomfield 600 - page 24

    SERVICING INSTRUCTIONS 22 TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank lid an d insert a thermometer of know n accuracy in vent hole. Reconnect brewer to e lectrical po wer. Place an empty decanter under brew chamber. Energize brewer and pour o ne decanter (64 oz.) of cold w a te ...

  • Bloomfield 600 - page 25

    SERVICING INST RUCTIONS (continued) 23 IMPORTA NT: Water pressure must be betwee n 20 p.s.i and 90 p.s.i. flowing pressure. If wate r pressure exceeds this value, or if water pressure varies g reatly, a pressure regulator must be installed in the w ater supply lin e. IMPORTA NT: Before se tting assembly into tank, make sure tank lid gasket is prope ...

  • Bloomfield 600 - page 26

    24 SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer d rips continuously from brew head. Unplug power cord or turn circuit breaker OFF . Turn OFF and disconnect w a ter supply from brewer inlet fitting. Unscrew water inlet fitting from sol e noid. Remove two screws holding access ...

  • Bloomfield 600 - page 27

    25 SERVICING INST RUCTIONS (continued) IMPORTA NT: When replacing water faucet coil, also rep l ace seal gaskets. NOTE : Any ab ra sion or roughness on the flat end of the seat cup will re quire replacing the seat cup: Work the seat cup out of the bonnet and off of the end of the stem. Install a ne w seat cup, mak ing sure the k nob on the st em is ...

  • Bloomfield 600 - page 28

    26 CA UTIO N - CH EMICA L BURN HA ZAR D Deliming chem icals are caustic. W ear ap pr op riate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th . This operation should only be perfo rm e d by qualifie d an d ex- perienced service personnel. IMPORT ANT: DO NOT spill, splash or pour water or d ...

  • Bloomfield 600 - page 29

    27 7. Set the tank back into the bre wer. Reassem ble the tank lid to the water tank. Mak e sure the gasket is properly in place, then reinstall the hold-down strap. 8. Reinstall wiring to h eating element and thermostat. Rein stall the hi-limit thermostat (if removed). For brewers with hot water faucet, reassem ble faucet piping. Verify that all i ...

  • Bloomfield 600 - page 30

    Bloo mfiel d I ndu stries, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -689-5 700 Fa x: 888 - 4 92-2783 Fa x: 800 - 3 56-5142 () websi te: www . wellsbl oomfiel d.com fo r orders only Bloomf ield Indus tri es pr oudly s upports CFESA Commerc ial Food Equ ipment Serv ice Ass ocia tion ...

Fabbricante Bloomfield Categoria Coffeemaker

I documenti che otteniamo dal fabbricante del dispositivoBloomfield 600 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bloomfield
- manuali per l’uso 600
- schede prodotto Bloomfield
- opuscoli
- o etichette energetiche Bloomfield 600
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bloomfield 600.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bloomfield 600, manuali di manutenzione, brevi manuali o manuali utente Bloomfield 600. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bloomfield 600.

Manuale completo del dispositivo Bloomfield 600, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bloomfield 600 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bloomfield 600.

Il manuale per l’uso completo Bloomfield, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bloomfield 600 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bloomfield 600, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bloomfield 600 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bloomfield 600 - che ci dovrebbe aiutare nei primi passi durante l'uso Bloomfield 600
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bloomfield 600
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bloomfield 600 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bloomfield 600?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bloomfield 600 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bloomfield 600 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)