    PO WER W A VE 455 M ™ OPERA TOR’S MANUAL IM807-A June, 2004 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING ...

  • Lincoln Electric POWER WAVE 455 M - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric POWER WAVE 455 M - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric POWER WAVE 455 M - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric POWER WAVE 455 M - page 5

    iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits ? ...

  • Lincoln Electric POWER WAVE 455 M - page 6

    v SAFETY v ...

  • Lincoln Electric POWER WAVE 455 M - page 7

    vi SAFETY vi ...

  • Lincoln Electric POWER WAVE 455 M - page 8

    vii vii Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. ...

  • Lincoln Electric POWER WAVE 455 M - page 9

    ix ix T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications - POWER WAVE 455M .................................................A-1 Safety Precautions................................................................................ ...

  • Lincoln Electric POWER WAVE 455 M - page 10

    x x T ABLE OF CONTENTS Page Troubleshooting ..............................................................................................Section E How to use Troubleshooting Guide .......................................................................E-1 Using the Status LED to Troubleshoot System Problems .....................................E-2 ...

  • Lincoln Electric POWER WAVE 455 M - page 11

    A-1 INST ALLA TION POWER WAVE 455M (CE) A-1 TECHNICAL SPECIFICA TIONS - POWER W A VE 455M (CE) (K2202-2) OUTPUT RECOMMENDED INPUT WIRE AND FUSE SIZES PHYSICAL DIMENSIONS PROCESS CURRENT RANGE (DC) CURRENT TEMPERA TURE RANGES INPUT A T RA TED OUTPUT - THREE PHASE ONL Y INPUT VOLTS 380V - 60HZ. 380V - 50HZ. 415V - 60HZ. 415V - 50HZ. OPEN CIRCUIT VOLT ...

  • Lincoln Electric POWER WAVE 455 M - page 12

    LIFTING Lift the machine by the lift bail only. The lift bail is designed to lift the power source only. Do not attempt to lift the Power Wave with accessories attached to it. ST ACKING Power Wave machines can be stacked to a maximum of 3 high. The bottom machine must always be placed on a firm, secure, level surface. There is a danger of machines ...

  • Lincoln Electric POWER WAVE 455 M - page 13

    A-3 INST ALLA TION A-3 INPUT CONNECTION Only a qualified electrician should connect the input leads to the Power Wave 455M (CE). Connections should be made in accordance with all local and national electrical codes and the connection dia- gram located on the inside of the reconnect/input access door of the machine. Failure to do so may result in bo ...

  • Lincoln Electric POWER WAVE 455 M - page 14

    A-4 INST ALLA TION POWER WAVE 455M (CE) A-4 CABLE INDUCT ANCE, AND ITS AFFECT ON PULSE WELDING For Pulse Welding processes, cable inductance will cause the welding performance to degrade. For the total welding loop length less than 15.24m (50 ft.), tra- ditional welding cables may be used without any effects on welding performance. For the total we ...

  • Lincoln Electric POWER WAVE 455 M - page 15

    A-5 INST ALLA TION POWER WAVE 455M (CE) A-5 Electrode Voltage Sensing Enabling or disabling electrode voltage sensing is automatically configured through software. The 67 electrode sense lead is internal to the cable to the wire feeder and always connected when a wire feeder is present. Important: The electrode polarity must be config- ured at the ...

  • Lincoln Electric POWER WAVE 455 M - page 16

    A-6 INST ALLA TION POWER WAVE 455M (CE) A-6 CONFIGURING THE SYSTEM For codes below 11100, consult the semi-automatic Power Feed instruction manual for configuration infor- mation about DIP switch settings. For codes above 11100 the power source will “ Auto Map ” the system eliminating most of the need to set DIP switches to configure the system ...

  • Lincoln Electric POWER WAVE 455 M - page 17

    A-7 INST ALLA TION POWER WAVE 455M (CE) A-7 In this case the individual feed heads need to be assigned to the dual head control and the PW455M auto map- ping disabled and the Equipment Groups set. (See the Feeder documentation for information on setting the feeder DIP switches) System that is NOT "Auto Mappable" POWER WAVE 455M (CE) POWER ...

  • Lincoln Electric POWER WAVE 455 M - page 18

    A-8 INST ALLA TION POWER WAVE 455M (CE) A-8 WELDING WITH MUL TIPLE POWER W A VES Special care must be taken when more than one Power Wave is welding simultaneously on a single part. Arc blow and arc interference may occur or be magnified. Each power source requires a work lead from the work stud to the welding fixture. Do not combine all of the wor ...

  • Lincoln Electric POWER WAVE 455 M - page 19

    A-9 INST ALLA TION POWER WAVE 455M (CE) A-9 MUL TIPLE ARC UNSYNCHRONIZED SENSE LEAD AND WORK LEAD PLACEMENT GUIDELINES ...

  • Lincoln Electric POWER WAVE 455 M - page 20

    A-10 INST ALLA TION POWER WAVE 455M (CE) A-10 I / O RECEPT ACLE SPECIFICA TIONS TABLE 3 WIRE FEEDER RECEPTACLE S1 PIN LEAD# FUNCTION A 53 Communication Bus L B 54 Communication Bus H C 67A Electrode Voltage Sense D 52 0vdc E 51 +40vdc TABLE 4 VOLTAGE SENSE RECEPTACLE S2 PIN LEAD# FUNCTION 3 21A Work Voltage Sense TABLE 5 RS232 RECEPTACLE S3 PIN LEA ...

  • Lincoln Electric POWER WAVE 455 M - page 21

    B-1 OPERA TION B-1 POWER WAVE 455M (CE) SAFETY PRECAUTIONS Read this entire section of operating instructions before operating the machine. ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrodes with your skin or wet clothing. • Insulate yourself from the work and ground. • Always wear dry insulating gloves. • Do not ...

  • Lincoln Electric POWER WAVE 455 M - page 22

    B-2 OPERA TION B-2 POWER WAVE 455M (CE) INPUT POWER ON OFF HIGH TEMPERA TURE MACHINE ST A TUS CIRCUIT BREAKER WIRE FEEDER POSITIVE OUTPUT NEGA TIVE OUTPUT 3 PHASE INVERTER INPUT POWER THREE PHASE DIRECT CURRENT GMA W FCA W GT A W OPEN CIRCUIT VOL T AGE INPUT VOL T AGE OUTPUT VOL T AGE INPUT CURRENT OUTPUT CURRENT PROTECTIVE GROUND W ARNING OR CAUTI ...

  • Lincoln Electric POWER WAVE 455 M - page 23

    B-3 OPERA TION B-3 POWER WAVE 455M (CE) DEFINITION OF WELDING TERMS NON-SYNERGIC WELDING MODES • A Non-synergic welding mode requires all welding process variables to be set by the operator. SYNERGIC WELDING MODES • A Synergic welding mode offers the simplicity of single knob control. The machine will select the cor- rect voltage and amperage b ...

  • Lincoln Electric POWER WAVE 455 M - page 24

    DeviceNet Interface Module This module can be used for DeviceNet capability. It will be a 5 pin sealed mini connector per ANSI B93.55M-1981. EtherNet/DeviceNet Module This module includes the DeviceNet and EtherNet capability. The DeviceNet uses a 5 pin sealed mini connector per ANSI B93.55M-1981. The EtherNet uses a RJ5 connector. RECOMMENDED EQUI ...

  • Lincoln Electric POWER WAVE 455 M - page 25

    B-5 OPERA TION POWER WAVE 455M (CE) B-5 CASE FRONT CONTROLS All operator controls and adjustments are located on the case front of the Power Wave 455m (CE). (See Figure B.1) 1 . POWER SWITCH: Controls input power to the Power Wave. 2. STATUS LIGHT: A two color light that indicates system errors. Normal operation is a steady green light. Error condi ...

  • Lincoln Electric POWER WAVE 455 M - page 26

    B-6 OPERA TION B-6 NOMINAL PROCEDURES The Power Wave 455M (CE) is designed to operate with 19.1mm (3/4") electrode stick-out for CV and Pulse processes. FRINGE PROCEDURES Excessively short or long electrode stick-outs may function only on a limited basis, if at all. MAKING A WELD The serviceability of a product or structure utiliz- ing the wel ...

  • Lincoln Electric POWER WAVE 455 M - page 27

    W a v e Con tr ol 0. 0 0 W a ve C o n trol + 10 . 0 W a ve C o n trol - 10.0 Current T ime CURRENT W A VE FORM (CV) B-7 OPERA TION B-7 • WELDING MODE May be selected by name (CV/MIG, CC/Stick Crisp, Gouge, etc.) or by a mode number (10, 24, 71, etc.) depending on the Control Box options. Selecting a welding mode determines the output characterist ...

  • Lincoln Electric POWER WAVE 455 M - page 28

    B-8 OPERA TION B-8 PULSE WELDING Pulse welding procedures are set by controlling an overall "arc length" variable. When pulse welding, the arc voltage is highly dependent upon the waveform. The peak current, back ground current, rise time, fall time and pulse frequency all affect the voltage. The exact voltage for a given wire feed speed ...

  • Lincoln Electric POWER WAVE 455 M - page 29

    C-1 ACCESSORIES C-1 OPTIONAL EQUIPMENT F ACTOR Y INST ALLED None Available. FIELD INST ALLED Work Voltage Sense Lead Kit, K940 Dual Cylinder Undercarriage, K1570-1. Gas Guard Regulator, K659-1 Coaxial welding Cable, K1796 Cool-Arc 40 K2187-1 (230V AC) Water Flow Sensor, K1536-1 Wire Drive Interface Module, K2205-1 DeviceNet interface Module, K2206- ...

  • Lincoln Electric POWER WAVE 455 M - page 30

    D-1 MAINTENANCE D-1 POWER WAVE 455M (CE) SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only Qualified personnel should perform this maintenance. • Turn the input power OFF at the disconnect switch or fuse box before working on this equipment. • Do not touch electrically hot parts. ROUTINE MAINTENANCE Routine maintenance consists of periodical ...

  • Lincoln Electric POWER WAVE 455 M - page 31

    E-1 TROUBLESHOOTING E-1 POWER WAVE 455M (CE) If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and re ...

  • Lincoln Electric POWER WAVE 455 M - page 32

    E-2 TROUBLESHOOTING E-2 POWER WAVE 455M (CE) USING THE ST A TUS LED TO TROUBLESHOOT SYSTEM PROBLEMS The Power Wave / Power Feed are best diagnosed as a system. Each component (power source, user inter- face, and feed head) has a status light, and when a problem occurs it is important to note the condition of each. In addition, errors displayed on t ...

  • Lincoln Electric POWER WAVE 455 M - page 33

    E-3 TROUBLESHOOTING E-3 POWER WAVE 455M (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION ER ...

  • Lincoln Electric POWER WAVE 455 M - page 34

    E-4 TROUBLESHOOTING E-4 POWER WAVE 455M (CE) Observe all Safety Guidelines detailed throughout this manual CAUTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance. PROBLEMS (SYMPTOMS) POSSIB ...

  • Lincoln Electric POWER WAVE 455 M - page 35

    E-5 TROUBLESHOOTING E-5 POWER WAVE 455M (CE) Observe all Safety Guidelines detailed throughout this manual CAUTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance. PROBLEMS (SYMPTOMS) POSSIB ...

  • Lincoln Electric POWER WAVE 455 M - page 36

    E-6 TROUBLESHOOTING E-6 POWER WAVE 455M (CE) Observe all Safety Guidelines detailed throughout this manual CAUTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance. PROBLEMS (SYMPTOMS) POSSIB ...

  • Lincoln Electric POWER WAVE 455 M - page 37

    F-1 DIAGRAMS F-1 POWER WAVE 455M (CE) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment cod ...

  • Lincoln Electric POWER WAVE 455 M - page 38

    F-2 CONNECTION DIAGRAM F-2 POWER WAVE 455M (CE) Connection Diagram Semi-automatic "Simple System" (Electrode Positive, CV/Pulse Configuration shown) POWER WAVE WIRE FEEDER CONTROL CABLE K1543 TO WORK ...

  • Lincoln Electric POWER WAVE 455 M - page 39

    F-3 DIAGRAMS F-3 POWER WAVE 455M (CE) 32.88 26.10 22.63 12.35 19.00 19.90 19.16 9.48 14.62 23.12 23.51 1 1-14-97 M18241 DIMENSION PRINT - PO WER W A VE 455M ...

  • Lincoln Electric POWER WAVE 455 M - page 40

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA EL ...

  • Lincoln Electric POWER WAVE 455 M - page 41

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes f ...

  • Lincoln Electric POWER WAVE 455 M - page 42

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabbricante Lincoln Electric Categoria Welder

I documenti che otteniamo dal fabbricante del dispositivoLincoln Electric POWER WAVE 455 M possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Lincoln Electric
- manuali per l’uso POWER WAVE 455 M
- schede prodotto Lincoln Electric
- opuscoli
- o etichette energetiche Lincoln Electric POWER WAVE 455 M
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Lincoln Electric POWER WAVE 455 M.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Lincoln Electric POWER WAVE 455 M, manuali di manutenzione, brevi manuali o manuali utente Lincoln Electric POWER WAVE 455 M. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Lincoln Electric POWER WAVE 455 M.

Manuale completo del dispositivo Lincoln Electric POWER WAVE 455 M, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Lincoln Electric POWER WAVE 455 M dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Lincoln Electric POWER WAVE 455 M.

Il manuale per l’uso completo Lincoln Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Lincoln Electric POWER WAVE 455 M - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Lincoln Electric POWER WAVE 455 M, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Lincoln Electric POWER WAVE 455 M che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Lincoln Electric POWER WAVE 455 M - che ci dovrebbe aiutare nei primi passi durante l'uso Lincoln Electric POWER WAVE 455 M
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Lincoln Electric POWER WAVE 455 M
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Lincoln Electric POWER WAVE 455 M in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Lincoln Electric POWER WAVE 455 M?

Utilizza il modulo sottostante

Se non hai risolto il problema con Lincoln Electric POWER WAVE 455 M con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Lincoln Electric POWER WAVE 455 M è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)