    Quick Start Guide 00825-0100-4774, Rev FA June 2014 Note Bef ore installing the transmitte r , con firm the correct device drive r is loaded on the host systems. See “Syste m readiness ” on page 3 . R osemount ® 3051 Pressure T ransmitt er R osemount 3051CF Series Flo wmeter T ransmitter with F OUNDATION ™ fieldbus prot ocol 00825-0100-4774_ ...

  • Emerson Rosemount 3051CF - page 2

    June 2014 2 Quick Start Guide NO TICE This installation guide provides basic guidelines for R osemount 3051 transmitters. It does no t provide instructions f or confi guration, di agnostics, main tenance , ser vice , troubleshoo ting, Explosion-Proof , Flame-Proof, or intrinsically saf e (I.S.) installa tions. Ref er to the 3051 ref ere nce manual ...

  • Emerson Rosemount 3051CF - page 3

    Quick Start Guide 3 June 2014 System re adiness Confirm correct device driv er  V erif y the correct device drive r (DD/DTM ™ ) is loaded on your syst ems to ens ur e p ro p er co mmu n ic at io ns .  Download the correc t device driver a t your host ve ndor download site, www .eme rsonprocess.c om or www .fieldbus.org . R ose mount 3051 de ...

  • Emerson Rosemount 3051CF - page 4

    June 2014 4 Quick Start Guide Figure 1. Installation Flowchart Start 1. T ransmitter installation 2 . Commissioning tag 6 . Configuration Done Locate device 7 . Zero tri m th e transmitter 5. Grounding, wiring and power up 3 . Housing rot at io n 4 . Set switches and softwar e write lock 00825-0100-4774_RevFA.fm Pag e 4 Friday, June 6, 2014 2:21 PM ...

  • Emerson Rosemount 3051CF - page 5

    Quick Start Guide 5 June 2014 T ransmitter installation St ep 1: Mount the transmitter Liquid applications Coplanar In-Line 1. Place taps to the side of the line. 2. Mount be side or be low the tap s. 3. Mount the trans mitte r so that the drain/ven t valves are oriented up ward. Ga s applications Coplanar In-Line 1. Plac e taps in t he top or side ...

  • Emerson Rosemount 3051CF - page 6

    June 2014 6 Quick Start Guide Figure 2. Panel and Pipe Mounting Bolting consider ations If the transmi tter installat ion requires assem bly of the proce ss flanges, man ifolds, or flange adapters, fo llow the assembly guideline s to ensure a tight seal for optimal performa nce charact eristics of the t ransmitters. Us e only bolts suppl ied with t ...

  • Emerson Rosemount 3051CF - page 7

    Quick Start Guide 7 June 2014 Figure 3. Common T ransmitte r Assemblies A. T ransmitter with C oplanar Flange B. T ransmitter with Coplanar Flan ge and Optional Flange Adapters C. T ransmitter with T raditional Flange and Optional Flange Adap ters D. T ransmi tter with Coplan ar Flange and Option al Manifold and Fl ange Adapt ers Bolts are typica l ...

  • Emerson Rosemount 3051CF - page 8

    June 2014 8 Quick Start Guide T able 2. T orque V alues for the Flange and Flange Ad apter Bolts O-rings with fl ange adapte rs Bolt materi al Head markings Initial torque Final torque Carbon Steel (CS) 300 in.-lbs. 650 in.-lbs. Sta in le ss St eel (S ST ) 150 in.-lbs. 300 in.-lbs. F ailure to instal l proper flange adapter O-rings may cause proces ...

  • Emerson Rosemount 3051CF - page 9

    Quick Start Guide 9 June 2014 Whenever the fl anges or adapte rs are removed, visually inspe ct the o-rings. Replace them if t here are any signs of d amage, such as nic ks or cuts. If you replace the o-rings, re-torque t he flange bolts an d alignment scre ws after installa tion to compensate for seating of the PTFE o-ring. Inline gage transmitte ...

  • Emerson Rosemount 3051CF - page 10

    June 2014 10 Quick Start Guide Figure 6. Commissioning T ag A. Device revision Note The device de scription loaded in the host system mu st be at the same re vision as this device. The devic e description can be downloaded from the host system we bsite or www .rosemo unt.c om by se lecting Download Devic e Drive r s under Product Quick Links. Y ou ...

  • Emerson Rosemount 3051CF - page 11

    Quick Start Guide 11 June 2014 Step 4: Set the switc hes Set Simulate an d Security switch configuration be fore installat ion as shown in Figure 8 .  The simulate switch en ables or disables simulated ale r ts and simulated AI Block status and values. The default simulate switch position is enabled.  The Securit y s witch allows (unlocked sy ...

  • Emerson Rosemount 3051CF - page 12

    June 2014 12 Quick Start Guide St ep 5: Wire, ground, and power up Use of copper wire of sufficient size to ensure th at the voltage across the transmitter power t erminals does not drop below 9 vdc. P ower supply volta ge can be varia ble, especi ally under ab normal conditions suc h as when ope rating on battery backup. A minimum of 12 vdc under ...

  • Emerson Rosemount 3051CF - page 13

    Quick Start Guide 13 June 2014 a. T rim the cable shie ld as short as practical and insu lat e from to uching the transmitter housing. Note Do NO T ground the cable shield a t the transmitter; if the cable shie ld touches the transmitte r housing, it can cre ate gro und loops and int erfere with c ommunica tions. b. C ontinuously c onnect th e cabl ...

  • Emerson Rosemount 3051CF - page 14

    June 2014 14 Quick Start Guide When the user exits the “Locate Device” meth od, the device LCD d isplay automatically ret urns to normal ope ration. Note Some hosts do not support “Locate De vice” in the DD . Step 6: Configure Each F OUNDATION fieldbus host or config uration tool has a different way of displaying an d performing configu rat ...

  • Emerson Rosemount 3051CF - page 15

    Quick Start Guide 15 June 2014 Figure 11. Basic Configur ation Menu T ree Before y ou begin See Figu re 10 to graphically view th e step by step process for basic device configuration. Be fore beginning configurat ion you may need to v erify the Device Tag or deactivat e hardware and softwa re write prote ction on the transm itter. To do this follo ...

  • Emerson Rosemount 3051CF - page 16

    June 2014 16 Quick Start Guide a. Navig ation : from the ove r view scree n, select “Devic e Inf orma tion ” and the n se lect the “Security and Simul ation” tab . b. P erform “Write Lock Setup ” to disable Soft ware Write Lock. Note Place the c ontrol loop in “Manual” mode bef o re beginning Analog Input Block configuration. AI blo ...

  • Emerson Rosemount 3051CF - page 17

    Quick Start Guide 17 June 2014 Note If the L_TYPE selected in Step 3 is “Direc t”, Step 4 , St ep 5 and Step 6 are not needed. If the L_T YPE selected is “Indi rect”, Step 6 is not needed. If guided setup is used any unneeded steps will aut omatically be skipped. 3. T o select the Signal Conditioning “L_T YPE” from the drop down menu: a ...

  • Emerson Rosemount 3051CF - page 18

    June 2014 18 Quick Start Guide 8. Configure optional L CD di splay (if installed). a. T o use guided setup :  Naviga te to Con figure, Guided Setup , and select “Local Display Setup”. Note Guided setup will automatically go through each step in the proper orde r .  Check the box nex t to each parameter to be displayed to a maximum of fou ...

  • Emerson Rosemount 3051CF - page 19

    Quick Start Guide 19 June 2014 AI block conf igur ation pa ramet ers Use the Pressure, DP Fl ow, and DP Level examples for guides. Pressure example DP Flow example Param ete rs Enter data Channe l 1=Pressure, 2=Se nsor T emp, 12=S PM mean, 13=S PM standard de viati on L-T y pe Dir ect, I ndi re ct, or Sq u ar e Ro ot XD_Scale Scale and Enginee ring ...

  • Emerson Rosemount 3051CF - page 20

    June 2014 20 Quick Start Guide DP Leve l example Displ ay pre ssure on the L CD displ ay Select the 'pre ssure' check bo x on the display con figuration sc reen. St ep 7: Zero trim the transmitt er Note T ransmitters are shipped fully calibrated per request or by the factor y default of full scale (s pan = uppe r range limit). A zero trim ...

  • Emerson Rosemount 3051CF - page 21

    March 2014 Quick Start Guide   3051 Product Certifications Rev 1.0 European Directive Information A copy of the EC Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EC Declaration of Conformity can be found at www.rosemount.com . Ordinary Location Certifi cation from FM Approvals As st ...

  • Emerson Rosemount 3051CF - page 22

    Quick Start Gui de March 2014  Markings: Explosionproof for Class I, Division 1, Groups B, C and D; Suitable for Class I, Zone 1, Group IIB+H2, T5; Dust-I gnitionproof Class II, Division 1, Groups E, F, G; Class III Division 1; Intrinsically Safe Cl ass I, Division 1 Groups A, B, C, D when connected in accordance with Rosemount drawing 03031-102 ...

  • Emerson Rosemount 3051CF - page 23

    March 2014 Quick Start Guide Special Conditions for Safe Us e (X): 1. The apparatus is not capable of withstanding the 500 V insulation test required by EN60079-11. This must be taken into account when installing the apparatus. 2. The enclosure may be made of aluminum allo y and given a protective polyuretha ne paint finish; how ever care should be ...

  • Emerson Rosemount 3051CF - page 24

    Quick Start Gui de March 2014 2. For information on the dimensions of t he flameproo f joints the manufacturer shall be contacted. 3. The capacitance of the wrap around label, bei ng 1. 6 nF, exceeds th e limit in Table 9 of EN60079-0. The user shall determine suit ability for the specific applic ation. 4. Some variants of the equipment have reduce ...

  • Emerson Rosemount 3051CF - page 25

    March 2014 Quick Start Guide Brazil E2 INMETRO Flameproof Certificate: UL-BR 13.0643X Standards: ABNT NBR IEC60079-0:2008 + Errat a 1:2011, ABNT NBR IEC60079- 1:2009 + Errata 1:2011, ABNT NBR IEC60 079-26:2008 + Errata 1:2008 Markings: Ex d IIC T6/T5 Ga/Gb, T6(-50°C ≤ Ta ≤ +65°C), T5 (-50°C ≤ Ta ≤ +80°C) Special Conditions for Safe Us e ...

  • Emerson Rosemount 3051CF - page 26

    Quick Start Gui de March 2014 China E3 China Flameproof Certificate: GYJ14.1041X; GYJ10.1313X [Flowmeters] Standards: GB3836.1-2000, GB38 36.2-2010, GB12476-2000 Markings: Ex d IIC T6/T5, T6(-50°C ≤ Ta ≤ +65°C), T5(-50° C ≤ Ta ≤ +80°C) Special Conditions of Us e (X): 1. The relation between ambient temperature ar range and temperature c ...

  • Emerson Rosemount 3051CF - page 27

    March 2014 Quick Start Guide Power P i 0.9 W 1.3 W 5.32 W Capacitance C i 0.012 µF 0 µF <5 nF Inductance L i 0 mH 0mH <10 µH Note 1: FISCO paramete rs apply to both Group IIC and IIB. Note 2: [For Flowmeters] When 644 te mperature tra nsmitter is used, the 644 temperature transmitter should be used with E x-certified associated apparatus t ...

  • Emerson Rosemount 3051CF - page 28

    Quick Start Gui de March 2014 GB3836.15-2000 “Electrical apparatus for explos ive gas atmospheres Part 15: Electrical installations in hazardous area (other than mines)” GB3836.16-2006 “Electrical apparatus for explosive gas atmospheres Part 16: Inspection and maintenance of electrical installation (other than mines)” GB50257-1996 “Code f ...

  • Emerson Rosemount 3051CF - page 29

    Quick Start Guide June 2014 00825-0100-4774_RevFA.fm Pag e 21 Friday, June 6, 2014 2:21 PM ...

  • Emerson Rosemount 3051CF - page 30

    June 2014 Quick Start Guide 00825-0100-4774_RevFA.fm Pag e 22 Friday, June 6, 2014 2:21 PM ...

  • Emerson Rosemount 3051CF - page 31

    Quick Start Guide June 2014 00825-0100-4774_RevFA.fm Pag e 23 Friday, June 6, 2014 2:21 PM ...

  • Emerson Rosemount 3051CF - page 32

    June 2014 Quick Start Guide 00825-0100-4774_RevFA.fm Pag e 24 Friday, June 6, 2014 2:21 PM ...

  • Emerson Rosemount 3051CF - page 33

    Quick Start Guide June 2014 00825-0100-4774_RevFA.fm Pag e 25 Friday, June 6, 2014 2:21 PM ...

  • Emerson Rosemount 3051CF - page 34

    Device revision (1) 1. 1. F OUNDATION fieldbus devic e revision can be read using a F OUNDATION fieldbus capable con figuration tool. Host De vice d rive r (DD) (2) 2.Device driver file names u se device and DD revision. T o access functional ity , the correct devi ce driv er mu st be insta lled on your control and asset ma nagement hos ts, and o n ...

Fabbricante Emerson Categoria Marine Instruments

I documenti che otteniamo dal fabbricante del dispositivoEmerson Rosemount 3051CF possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Emerson
- manuali per l’uso Rosemount 3051CF
- schede prodotto Emerson
- opuscoli
- o etichette energetiche Emerson Rosemount 3051CF
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Emerson Rosemount 3051CF.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Emerson Rosemount 3051CF, manuali di manutenzione, brevi manuali o manuali utente Emerson Rosemount 3051CF. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Emerson Rosemount 3051CF.

Manuali per l’uso simili

Manuale completo del dispositivo Emerson Rosemount 3051CF, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Emerson Rosemount 3051CF dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Emerson Rosemount 3051CF.

Il manuale per l’uso completo Emerson, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Emerson Rosemount 3051CF - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Emerson Rosemount 3051CF, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Emerson Rosemount 3051CF che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Emerson Rosemount 3051CF - che ci dovrebbe aiutare nei primi passi durante l'uso Emerson Rosemount 3051CF
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Emerson Rosemount 3051CF
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Emerson Rosemount 3051CF in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Emerson Rosemount 3051CF?

Utilizza il modulo sottostante

Se non hai risolto il problema con Emerson Rosemount 3051CF con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Emerson Rosemount 3051CF è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)