  • TFA 42.7003 - page 1

    1 GUIDE Cat. No. 42.7003 Instruction M anual INTRODUCTION This de v ice is a digital product that pro v ides altimeter, barometer, compass, altimeter data, dual time, chronograph, chronograph data and alarm functions. Features: Altimeter - 1 meter (or foot) resolution and w ith w orking range from -700 meters ( -2296 feet) to 9000 meters (29520 fee ...

  • TFA 42.7003 - page 2

    2 Chronograph - 1/100-second resolution w ith w orking range up to 24 hours. - 100 memories for lap/split times stored in a maximum of 30 runs. Alarm - 2 daily alarms. - Hourly chime. Electro-luminescent backlight - 3 seconds light up EL backlight. Altimetermode with altitude change: measures ever y 2,5 seconds Altimetermode without altitude change ...

  • TFA 42.7003 - page 3

    3 BASIC OPERATION OF BUTTONS A: - S W ITCH AMONG DISPLAYS - TAKE BEARING - STORE ALTITUDE DATA (PRESS AND HOLD) - FOR W ARD SELECTION OF ALTITUDE DATA - START/LAP OF CHRONOGRAPH - RETRIEVE DATA IN RUN - TURN ALARM ON AND OFF - FOR W ARD SETTING (SET OR CALIBRATION) B: - S W ITCH BET W EEN NORMAL TIME AND DUAL TIME (PRESS AND HOLD) - S W ITCH BET W ...

  • TFA 42.7003 - page 4

    4 MODE CHANGE OPERATION There are 9 modes: Normal Time, Dual Time, Compass, Barometer, Altimeter, Altimeter Data, Chronograph, Chronograph Data and Alarm. Press C to change from mode to mode, hold do w n B to s w itch bet w een Normal Time mode and Dual Time mode as in the follo w ing: * At any mode, holding do w n C w ill change to Time mode direc ...

  • TFA 42.7003 - page 5

    5 TIME MODE Use C to enter Time mode. * Mode prompt “TIME” is displayed first. - There are 2 time modes, Normal Time (indicated by T1) and Dual Time ( indicated by T2), and they count up indi v idually w ith the same second. - There are 3 displays for time. They are Time, Time w ith Barometer and Time w ith W eather. - There is an auto -calenda ...

  • TFA 42.7003 - page 6

    6 2. Use A (+) and B ( -) to chang e the setting. Holding do w n either button scrolls the setting at high speed. 3. Press C to ad v ance to the next setting as in the follo w ing: * W hen second digits are flashing, press A or B to reset the digits to 00. Resetting seconds w hen the digi ts are bet w een 00 to 29 w ill lea v e the minute digits un ...

  • TFA 42.7003 - page 7

    7 TENS OF DEGREE DEGREE E/W C C C 2. Rotate the product clock w ise slo w ly for 2 complete rotations * Each rotation must last for at least 15 seconds. Keep the w atch in a le v el position w hen calibrating. Do a v oid close contact to metal parts or other electrical instruments, w hen calibrating. 3. Press D and the ten -degree digit starts to f ...

  • TFA 42.7003 - page 8

    8 BAROMETER MODE Barometer mode indicator Use C to enter Barometer mode. * Mode prompt “BARO” is displayed first. - Barometer mode indicator is sho w n. - The barometer is of 1 hPa resolution and w ith w ork ing range from 300 hpa to 1100 hpa. - Both sea le v el pressure and absolute pressure can be sho w n. - Graph sho w ing the changes in sea ...

  • TFA 42.7003 - page 9

    9 To switch between °F and °C 1. Use A or E to s w itch to the barometer display w ith temperature. 2. Hold do w n B until the unit indicator (°F or °C) stops flashi ng to s w itch temperature bet w een °F and °C. To set sea level pressure reading 1. Hold do w n D until “SET CURRENT W EATHER” scrolls on the display, w hich indicates the w ...

  • TFA 42.7003 - page 10

    10 ALTIMETER MODE Use C to enter Altimeter mode. * Mode prompt “ALTI” is displayed first. - Altimeter mode indicator is sho w n. - The altimeter is of 1 meter (or foot) resolution an d w ith w orking range from -700 meters ( -2296 feet) to 9000 meters (29520 feet). - Altitude reading in meters or feet selectable. - Graph sho w ing the changes i ...

  • TFA 42.7003 - page 11

    11 ALTIMETER DATA MODE Use C to enter Altimeter Data mode. * Mode prompt “ALTI DATA” is displayed first. - Data number, time, dat e and altitude reading can be retrie v ed. * Altitude data are sho w n in 2 different displays. To retrieve the altitude data 1. Use A (+) and B ( -) to select the altitude data to be retrie v ed. 2. Press E to s w i ...

  • TFA 42.7003 - page 12

    12 seconds, then the display w ill sho w the current running ti mes automatically. To measure elapsed time 1. Press A to start the chronograph. 2. Press B to stop the chronograph. * You can resume the measurement operation by pressing A. 3. Hold do w n B until the next run number is sho w n on the display. * Data of the current r un is stored and c ...

  • TFA 42.7003 - page 13

    13 * Returns to chronograph display automatically after 3 seconds or w hen any button is pressed. MODO DATOS DE CRONÓGRAFO Use C to enter Chronograph Data mode. * Mode prompt “CHRO DATA” is displayed first. - Run number, date, lap/split time of each lap, best lap time and a v erage lap time can be retrie v ed. - If chronograph is running, chro ...

  • TFA 42.7003 - page 14

    14 To clear all runs Hold do w n D until “----” is sho w n on the display. * All runs are cleared. ALARM MODE Use C to enter Alarm mode. * Mode prompt “ALRM” is displayed first. - There are 2 daily alarms and they can be set to refer to Normal Time (indicated by T1) or Dual Time (indicated by T2). - Daily alarm sounds at the same time each ...

  • TFA 42.7003 - page 15

    15 To turn the alarm on and off Press A to turn the alarm on (indicated by ON) and off (indicated by OFF). * If the alarm is turned on, the alarm on indicator w ill be sho w n. RESETTING THE PRODUCT Hold do w n A, B, C and D simultaneously, all segments w ill be “on”, then release the buttons and the product w ill be reset. * After reset, there ...

Fabbricante TFA Categoria Sport Watch

I documenti che otteniamo dal fabbricante del dispositivoTFA 42.7003 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici TFA
- manuali per l’uso 42.7003
- schede prodotto TFA
- opuscoli
- o etichette energetiche TFA 42.7003
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso TFA 42.7003.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione TFA 42.7003, manuali di manutenzione, brevi manuali o manuali utente TFA 42.7003. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto TFA 42.7003.

Manuali per l’uso simili

Manuale completo del dispositivo TFA 42.7003, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare TFA 42.7003 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti TFA 42.7003.

Il manuale per l’uso completo TFA, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale TFA 42.7003 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice TFA 42.7003, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per TFA 42.7003 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo TFA 42.7003 - che ci dovrebbe aiutare nei primi passi durante l'uso TFA 42.7003
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del TFA 42.7003
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio TFA 42.7003 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su TFA 42.7003?

Utilizza il modulo sottostante

Se non hai risolto il problema con TFA 42.7003 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con TFA 42.7003 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)